If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23874 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.15,"lon":-80.61,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: WALLEY | |
License Status: Producing | |
License Date: 2007-07-30 | |
Spud Date: 2007-08-10 | |
Spud Drilling Contractor: YOST DRILLING | |
Final Drill Date: 2007-08-15 | |
Well Total Depth: 5295.00 ft | |
Configuration: Vertical | |
Latitude: 41.150000 | |
Longitude: -80.610000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-07-30 | Proposed Formations:CLINTON, Issued Date:7/30/2007, Expired Date:7/29/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-08-15 | |
Reached Total Depth | 2007-08-15 | |
Completion Report Received | 2007-10-01 | |
Construction Permit Expires | 2008-07-29 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-01-15 | 4982 | 5062 | 48 |
2008-01-15 | 5148 | 5152 | 3 |
4982 | 5062 | 48 | |
5148 | 5152 | 3 | |
4982 | 5062 | 48 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 20 | 0 | 50000 | 500 GALLONS IC ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | 127448.00 | 461.00 | 347 |
2009 | PAC DRILLING LLC | 20897.00 | 256.00 | 354 |
2010 | PAC DRILLING LLC | 15849.00 | 247.00 | 344 |
2011 | PAC DRILLING LLC | 10736.00 | 264.00 | 341 |
2012 | PAC DRILLING LLC | 4158.00 | 155.00 | 363 |
2013 | PAC DRILLING LLC | 3128.00 | 130.00 | 365 |
2014 | PAC DRILLING LLC | 2463.00 | 120.00 | 360 |
2015 | PAC DRILLING LLC | 2132.00 | 51.00 | 360 |
2016 | PAC DRILLING LLC | 2598.00 | 78.00 | 358 |
2017 | PAC DRILLING LLC | 3058.00 | 131.00 | 359 |
2018 | PAC DRILLING LLC | 2700.00 | 51.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | Brine | 75 | 347 |
2009 | PAC DRILLING LLC | Brine | 67 | 354 |
2010 | PAC DRILLING LLC | Brine | 68 | 344 |
2011 | PAC DRILLING LLC | Brine | 48 | 341 |
2012 | PAC DRILLING LLC | Brine | 49 | 363 |
2013 | PAC DRILLING LLC | Brine | 5 | 365 |
2014 | PAC DRILLING LLC | Brine | 25 | 360 |
2015 | PAC DRILLING LLC | Brine | 22 | 360 |
2016 | PAC DRILLING LLC | Brine | 15 | 358 |
2017 | PAC DRILLING LLC | Brine | 22 | 359 |
2018 | PAC DRILLING LLC | Brine | 0 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1772198343 | 2020-5-14 0:00: | UP | No Violations | |
-655043418 | 2019-11-18 0:00 | UP | No Violations | |
0004431161 | 2017-02-15 | UrbanProduction Wells | No Violations
--9-05(E)(1)(a--3873. - PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). -up lines or remove the handles per 1501:9-9-05(E)(3) 4) Repair or build a new dike around the tank battery. | |
0158426836 | 2018-07-16 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 324495658. At the time of this inspection, the fence man door still needed a lock. Inside the diked tank battery, the pick-up line has a plug, but was leaking brine around the elbow connection on the line. Salt crystals had formed along the length of the pick-up line. The required urban safety equipment was still missing from the production tank, and needs to be installed per 1501:9-9--e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9--e). Landscaping at the tank battery has not been installed. The tank battery is shared with permit 2-3873. I contacted Rusty Hornhill of PAC Drilling, LLC about addressing the leak on the pick-up line and cleaning up any impacted soil from the brine leak. |
0324495658 | 2018-05-11 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted on the chain link fence that surrounds the well with no lock. A lock needs installed at the well fence. The tank battery has two storage tanks and a separator. The dike has been rebuilt on the north end of the tank battery. The pick-up line has a plug, but a missing lock. The required urban safety equipment was missing from the production tank, and needs to be installed per 1501:9-9--e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9--e). There was no landscaping at the tank battery; however, the tank battery is located approximately 1,500 feet south of Route 304 on commercial/industrial property with trees and vegetation on the north and east sides. The access road was stable with no gate at the entrance. The access road was the entrance for several commercial/industrial businesses. The tank battery is shared with permit 2-3873. |
0380277218 | 2014-06-26 | UrbanProduction Wells | No Violations | I was on location to perform a status check inspection. I found during my inspection the well equipped with a plunger lift unit that was in production. The tank battery consisted of a 210 barrel production tank, a 50 barrel, poly brine tank and a separator. A dike surrounded the tank battery. Identification signs were posted at the well and tank battery. There was a wooden fence around the production equipment and a locked, chain link fence around the well. The door to the wooden fence was lying on the ground. A bull plug was installed on the load line. There was no urban safety equipment on the production tank. The lease road was in good condition. I called PAC Drilling and instructed Gus to:
Install the required safety equipment by 9/26/2014 Repair the wooden door on the fencing surrounding the production equipment A follow-up inspection will be performed by 9/26/2014. |
0556172989 | 2007-08-13 | Drill / Deepen / Reopen | No Violations | Kilbarger drilling at 3865 . |
1020911287 | 2017-09-07 | UrbanProduction Wells | No Violations
---3873. I spoke with Rusty Thornhill to add locks to the fences around the tank battery and well, install a plug on the 2 nipple, and install the urban safety equipment. | |
1549472424 | 2019-02-04 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 324495658, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the fence man door still needed a lock. The brine tank valve leak was not actively leaking, at the time of this inspection, but the tank did not appear to be repaired. The required urban safety equipment was still missing from the production tank, and needs to be installed per 1501:9-9-05E(4)(b-e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9-05E(1)(a-e). Landscaping at the tank battery has not been installed per 1501:9-9-05(E)(6)(a-c).
PAC needs to: 1) Install locks on the well and tank battery man doors. 2) Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 3) Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e): Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor 4) Install the landscaping at the tank battery location as required per 1501:9-9-05(E)(6)(a-c). |
158426836 | 2018-7-16 0:00: | UP | No Violations | |
1678881884 | 2011-09-16 | Preliminary Restoration | No Violations | Preliminary Restoration was acceptable. |
324495658 | 2018-5-11 0:00: | UP | No Violations | |
380277218 | 2014-6-26 0:00: | UP | No Violations | |
4431161 | 2017-2-15 0:00: | UP | No Violations | 0.50 |
556172989 | 2007-8-13 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0324495658 | US-OH-123403 | 2018-05-25 | 9-05E1 | ID (a-i) |
0324495658 | US-OH-123404 | 2018-05-25 | 9-05E3 | LOCKS |
0324495658 | US-OH-123405 | 2018-05-25 | 9-05E4 | TANKS (a-i) |
For data sources see[9]