Well Details

Well ID: 34-155-23882
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: FERRARA J V
License Status: Producing
License Date: 2007-10-19
Spud Date: 2007-10-25
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2007-11-02
Well Total Depth: 5364.00 ft
Configuration: Vertical
Latitude: 41.160000
Longitude: -80.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-10-19 Proposed Formations:CLINTON, Issued Date:10/19/2007, Expired Date:10/18/2008 6:00:00 AM, Drilling unit acres:221.51, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-11-02
Completion Report Received 2008-03-04
Construction Permit Expires 2008-10-18
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-07-01 5017 5136 61
5017 5136 61
5017 5136 61

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 40700 FRAC WATER VOLUME WAS NOT REPORTED… GM

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 CGAS EXPLORATION 200.00 0.00 30
2008 PAC DRILLING LLC 29467.00 694.00 350
2009 PAC DRILLING LLC 23384.00 366.00 354
2010 PAC DRILLING LLC 20003.00 369.00 351
2011 PAC DRILLING LLC 9072.00 329.00 346
2012 PAC DRILLING LLC 4730.00 224.00 364
2013 PAC DRILLING LLC 4674.00 197.00 365
2014 PAC DRILLING LLC 5003.00 166.00 360
2015 PAC DRILLING LLC 4121.00 106.00 360
2016 PAC DRILLING LLC 2600.00 156.00 355
2017 PAC DRILLING LLC 2601.00 119.00 356
2018 PAC DRILLING LLC 3223.00 162.00 357

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 CGAS EXPLORATION Brine 0 30
2008 PAC DRILLING LLC Brine 50 350
2009 PAC DRILLING LLC Brine 46 354
2010 PAC DRILLING LLC Brine 48 351
2011 PAC DRILLING LLC Brine 0 346
2012 PAC DRILLING LLC Brine 0 364
2013 PAC DRILLING LLC Brine 69 365
2014 PAC DRILLING LLC Brine 51 360
2015 PAC DRILLING LLC Brine 40 360
2016 PAC DRILLING LLC Brine 0 355
2017 PAC DRILLING LLC Brine 27 356
2018 PAC DRILLING LLC Brine 25 357

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1043485763 2018-5-21 0:00: UP No Violations
-14855066 2012-1-11 0:00: PW No Violations
0014855066 2012-01-11 Production Wells No Violations There were no violations at the time of inspection.
1043485763 2018-05-21 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly, and the annulus and flow line valves were open. There was no identification posted at the well. A domestic gas supply comes off of the wellhead with an open 2 inch flow line ball valve, four regulators, a drip tank, and a gas meter. The wooden fence around the well was missing boards and was not secure. The diked tank battery has four storage tanks and two separators. The pick-up lines have plugs and the handles have been removed. The wooden fence around the tank battery has missing boards and damage from falling trees and branches. The man-door on the wooden fence was unsecure with no lock. The required urban safety equipment was installed on both production tanks. The top of the production tanks extend more than 3 foot above the fence. An identification sign was posted on the wooden fence, but was missing the required information per 1501:9-9-05(E)(1)(a-e). There was no landscaping at the tank battery. The fenced tank battery was approximately 90 feet from Route 304. The access road was stable but with no gate at the entrance. The access road gate was not waived during the pre-site inspection. The tank battery is shared with permit #2-3883.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Repair the wooden fences surrounding the tank battery and well. 4) Secure the wooden fences with locks. 5) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 6) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 7) Complete the required landscaping on the south and west sides o

120027581 2019-11-18 0:00 UP No Violations
1382014232 2013-10-17 UrbanPreliminary Restoration No Violations My inspection found the well in production. The proper urban safety equipment was installed on the two production tanks. The site was graded and vegetation was well established. The proper identification signs were posted. The dike met containment requirements. There were locked wooden fences surrounding the tank battery and well. Preliminary restoration passed.
1489593175 2017-02-15 UrbanProduction Wells No Violations

---up with the missing plug. The wooden fence around the tank battery has missing boards and damage from falling trees and branches. The man--9-05(E)(1)(a--site inspection. The tank battery is shared with permit #2-3883.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f).

1551289377 2019-02-27 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1043485763, regarding multiple compliance issues related to urban site requirements. At the time of this inspection, none of the compliance items that were noted in the initial compliance notice have been addressed.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Repair the wooden fences surrounding the tank battery and well. 4) Secure the wooden fences with locks. 5) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 6) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 7) Complete the required landscaping on the south and west sides of the tank battery per 1501:9-9-05(E)(6)(a-c). 8) Install identification at the well location.

1586961848 2020-4-15 0:00: UP No Violations
1777909556 2007-10-30 Drill / Deepen / Reopen No Violations Kilbarger drilling at 4148 .
1792135814 2013-10-09 UrbanProduction Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit and a domestic gas line. The tank battery contained two, 100 barrel production tanks, two, 50 barrel brine tank, and two separators. There were plugs on the load lines. There was no safety equipment on the production tanks. The dike met containment requirements. The proper identification sign was posted at the tank battery, but not the well. There were wooden fences surrounding the tank battery and well. The gate on the fence at the tank battery was off the hinges. The lease road was in good condition. I called PAC at 330-874-3781. I instructed PAC to install the proper safety equipment, fix the fence gate, and post the proper identification sign at the well.
705961958 2019-10-22 0:00 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1043485763 US-OH-100660 2018-06-06 9-05E1 ID (a-i)
1043485763 US-OH-100661 2018-06-06 9-05E2 FENCING (a-d)
1043485763 US-OH-100662 2018-06-06 9-05E3 LOCKS
1043485763 US-OH-100663 2018-06-06 9-05E4 TANKS (a-i)
1043485763 US-OH-100664 2018-06-06 9-05E6 LANDSCAPING (a-c)