X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23888

Well Details

Well ID: 34-155-23888
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Johnston Township
Operator Name: AMERICAN ENERGY ASSOCIATES INC
Well Pad ID:
Farm/Lease Name: DENMAN
License Status: Producing
License Date: 2007-11-30
Spud Date: 2008-01-23
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-01-30
Well Total Depth: 4510.00 ft
Configuration: Vertical
Latitude: 41.380000
Longitude: -80.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-30 Proposed Formations:CLINTON, Issued Date:11/30/2007, Expired Date:11/29/2008 6:00:00 AM, Drilling unit acres:41.059, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-30
Construction Permit Expires 2008-11-29
Completion Report Received 2009-02-03
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-17 4283 4390 64
2009-03-17 4446 4449 3
4283 4390 64
4446 4449 3
4283 4390 64

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 73698 Gal 37500 FRAC ALSO TREATED THE MEDINA SANDSTONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 AMERICAN ENERGY ASSOCIATES INC 0.00 0.00 0
2010 AMERICAN ENERGY ASSOCIATES INC 1563.00 81.00 185
2011 AMERICAN ENERGY ASSOCIATES INC 1430.00 111.00 365
2012 AMERICAN ENERGY ASSOCIATES INC 1297.00 59.00 366
2013 AMERICAN ENERGY ASSOCIATES INC 624.00 124.00 365
2014 AMERICAN ENERGY ASSOCIATES INC 961.00 0.00 365
2015 AMERICAN ENERGY ASSOCIATES INC 1546.00 78.00 365
2016 AMERICAN ENERGY ASSOCIATES INC 1264.00 0.00 365
2017 AMERICAN ENERGY ASSOCIATES INC 932.00 0.00 365
2018 AMERICAN ENERGY ASSOCIATES INC 667.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 AMERICAN ENERGY ASSOCIATES INC Brine 0 0
2010 AMERICAN ENERGY ASSOCIATES INC Brine 305 185
2011 AMERICAN ENERGY ASSOCIATES INC Brine 143 365
2012 AMERICAN ENERGY ASSOCIATES INC Brine 62 366
2013 AMERICAN ENERGY ASSOCIATES INC Brine 112 365
2014 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2015 AMERICAN ENERGY ASSOCIATES INC Brine 109 365
2016 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2017 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2018 AMERICAN ENERGY ASSOCIATES INC Brine 88 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1244454149 2017-6-21 0:00: PW No Violations 1.50
-1420767964 2014-3-6 0:00:0 PW No Violations 0.70
-1666509675 2017-12-29 0:00 PW No Violations 0.30
0346596286 2008-01-26 Drill / Deepen / Reopen No Violations Capstar rigging up to drill out from under surface casing .
1235310993 2009-12-08 Preliminary Restoration No Violations no violations .
1244454149 2017-06-21 Production Wells No Violations

-up line is secure with a plug. An identification sign is posted. A deduct meter and 7 day chart dated 6/21/17 is installed on the sales line after the separator. The production tank has some rust pitting. The access road is in good repair with a Dominion Master Meter near the entrance.

The equipment on site:



1420767964 2014-03-06 Production Wells No Violations My inspection found the well in production. The well was equipped with a pumping unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a vertical separator. All of the production equipment spacing was in compliance. The dike met containment requirements. There was a 7 day production chart at the separator dated 3/4/2014. The proper identification sign was posted on the production tank. A bull plug was properly installed on the load line. The lease road was in stable condition.
1666509675 2017-12-29 Production Wells No Violations I was on location to assess Chiefs Order 2017-274. I found the pumping unit in production with open flow line ball valves. There is a chart box and 7 day chart dated 12/26/2017 on the sales line after the separator. There are two storage tanks within the diked tank battery. An identification sign is posted. I spoke with Bob Barnett from American Energy Associates. Mr. Barnett stated the company does have insurance and will call Columbus ODNR on 1/2/2018 to correct the issue.

American Energy needs to: Immediately shut-in the production well Submit updated Liability Insurance

346596286 2008-1-26 0:00: DD No Violations

For data sources see[9]

References