34-155-23953

Well Details

Well ID: 34-155-23953
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bristol Township
Operator Name: CEDAR VALLEY ENERGY INC
Well Pad ID:
Farm/Lease Name: SHIPMAN
License Status: Producing
License Date: 2019-04-11
Spud Date: 2008-09-05
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-09-09
Well Total Depth: 4238.00 ft
Configuration: Vertical
Latitude: 41.380000
Longitude: -80.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-08-04 Proposed Formations:CLINTON, Issued Date:8/4/2008, Expired Date:8/4/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-09-09
Completion Report Received 2008-10-27
APP 2019-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2019, Expired Date:4/10/2021 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2019-04-18
Construction Permit Expires 2021-04-10

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-02 3965 4017 32
3965 4017 32
3965 4017 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 100 Mscf 62000 FRAC ALSO INVOLVED 100,900 GAL OF WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CEDAR VALLEY ENERGY INC 0.00 87.00 30
2009 CEDAR VALLEY ENERGY INC 2256.00 722.00 365
2010 CEDAR VALLEY ENERGY INC 1269.00 740.00 365
2011 CEDAR VALLEY ENERGY INC 1258.00 357.00 365
2012 CEDAR VALLEY ENERGY INC 1474.00 393.00 366
2013 CEDAR VALLEY ENERGY INC 1085.00 404.00 365
2014 CEDAR VALLEY ENERGY INC 800.00 167.00 365
2015 CEDAR VALLEY ENERGY INC 398.00 95.00 365
2016 CEDAR VALLEY ENERGY INC 100.00 32.00 60
2017 CEDAR VALLEY ENERGY INC 0.00 0.00 0
2018 CEDAR VALLEY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CEDAR VALLEY ENERGY INC Brine 392 30
2009 CEDAR VALLEY ENERGY INC Brine 1186 365
2010 CEDAR VALLEY ENERGY INC Brine 1833 365
2011 CEDAR VALLEY ENERGY INC Brine 1390 365
2012 CEDAR VALLEY ENERGY INC Brine 1692 366
2013 CEDAR VALLEY ENERGY INC Brine 1409 365
2014 CEDAR VALLEY ENERGY INC Brine 961 365
2015 CEDAR VALLEY ENERGY INC Brine 578 365
2016 CEDAR VALLEY ENERGY INC Brine 121 60
2017 CEDAR VALLEY ENERGY INC Brine 0 0
2018 CEDAR VALLEY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1162611147 2016-08-22 Production Wells No Violations

-4074.

The equipment on the site consists of the following:



1542757539 2019-03-13 Production Wells Violations Noted I conducted an inspection on this well. At the time of my inspection, the well was equipped with a 4.5 inch casing and ball valve. The valve on the casing was closed and the 2 inch flow line has been disconnected at the well location. There was a 2 inch line that was plumbed above grade from the 8 5/8 inch casing. A ball valve connection was plumbed onto the 2 inch line. Brine was observed leaking from a loose fitting on the the valve connection. Staining on the wooden base behind the well from the leak was also present, at the time of this inspection. The production records were submitted in 2016 with 32 BBL of oil and 100 mcf of gas. In 2017, production records were submitted as zero. The tank battery has three 100 BBL tanks, two 50 BBL tanks and two separators. A Dominion East Ohio master meter was located within the diked battery. A compressor was also present adjacent to the tank battery on the west side. Identification was posted at the tank battery and well. The load lines are secure with locks and plugs. The production equipment and access road are in good repair. The well has its own production equipment but shares the diked tank battery location with permit number 2-4074. I contacted Cedar Valley Energy, Inc. and left message with the main office to discuss the leak and future plans for this well. The leak at the well needs to be remedied immediately and the well put back into production or plugged.
1566311838 2019-8-20 0:00: PW No Violations
1822799454 2012-09-14 Production Wells No Violations I completed a production preliminary restoration inspection. My inspection found the well equipped with a pumping unit that was in good condition. The tank battery contained one, 100 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and the proper identification sign. The production equipment had the proper spacing, all debris has been removed, the proper dike has been installed, and all pits have been closed. The lease road was in good condition.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1542757539 US-OH-114930 2019-04-25 Well operation causing pollution and contamination

For data sources see[9]