X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23977

Well Details

Well ID: 34-155-23977
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: HUDACK
License Status: Producing
License Date: 2009-12-30
Spud Date: 2010-01-14
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2010-01-19
Well Total Depth: 5291.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-30 Proposed Formations:CLINTON/MEDINA, Issued Date:10/30/2008, Expired Date:10/30/2009 6:00:00 AM, Drilling unit acres:236.73, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2009-12-30 Proposed Formations:CLINTON/MEDINA, Issued Date:12/30/2009, Expired Date:12/30/2010 6:00:00 AM, Drilling unit acres:237.9, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-01-19
Completion Report Received 2010-06-01
Construction Permit Expires 2010-12-30
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-08-04 5005 5070 56
5005 5070 56
5005 5070 56

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 47500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 PAC DRILLING LLC 21064.00 431.00 329
2011 PAC DRILLING LLC 14076.00 390.00 346
2012 PAC DRILLING LLC 7606.00 203.00 364
2013 PAC DRILLING LLC 4760.00 0.00 365
2014 PAC DRILLING LLC 5679.00 165.00 360
2015 PAC DRILLING LLC 4155.00 0.00 360
2016 PAC DRILLING LLC 2656.00 86.00 355
2017 PAC DRILLING LLC 2355.00 86.00 356
2018 PAC DRILLING LLC 2686.00 74.00 357

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 PAC DRILLING LLC Brine 0 329
2011 PAC DRILLING LLC Brine 50 346
2012 PAC DRILLING LLC Brine 41 364
2013 PAC DRILLING LLC Brine 0 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 0 360
2016 PAC DRILLING LLC Brine 0 355
2017 PAC DRILLING LLC Brine 0 356
2018 PAC DRILLING LLC Brine 0 357

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1007789632 2018-5-14 0:00: UP No Violations
-1105779601 2010-1-14 0:00: DD No Violations
-124366076 2016-7-21 0:00: UP No Violations 0.50
-1528281067 2010-2-4 0:00:0 PL No Violations
-1846768788 2017-4-20 0:00: PW No Violations 0.20
-244245363 2010-2-8 0:00:0 PL No Violations
0124366076 2016-07-21 UrbanProduction Wells Violations Noted

-3975 and 2-3974. I spoke with Rusty Hornhill, well tender for PAC Drilling, concerning the identification sign, the missing lock and the required safety equipment. A compliance notice has been issued.

PAC Drilling has 45 days to: Install the proper urban safety equipment.


-pressure relief valve

Post an identification sign at the tank battery. Install locks on the load line ball valves on the production tanks.

The equipment on the site consists of the following:



0244245363 2010-02-08 Preliminary Restoration No Violations Drilling pits have been closed . No violations .
1007789632 2018-05-14 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 124366076. At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. An identification sign was posted at the well. There was no fencing around the well. The well was located in an open field surround by woods, and not visible from Drummand Avenue. The diked tank battery has three storage tanks and a separator. The pick-up line has a plug and the ball valve handle has been removed. The 210 BBL storage tank was missing some the required urban safety equipment. An identification sign was posted at the tank battery. The identification sign was missing the required information per 1501:9-9---site inspection. The tank battery was shared with wells 2-3974 and 2-3975.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning lightning arrestor. 4) Install the fencing around the well.

1105779601 2010-01-14 Drill / Deepen / Reopen No Violations Capstar rigging up . No violations .
1528281067 2010-02-04 Preliminary Restoration No Violations Drilling pits have been closed . No violations .
1801741184 2019-03-01 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 124366076, regarding multiple compliance issues relating to urban rule requirements. At the time of this inspection, No fencing has been installed around the well and has not been waived during the pre-site meeting. The 210 BBL production tanks have been outfitted with the required urban safety equipment. The identification posted at the tank battery, still needs amended with the required information per 1501:9-9-05E(1)(a-e). There was a locked chain link fence with 3 strand barb wire surrounding the tank battery. The production tank was 3 foot above the top of the fence. There was no landscaping at the tank battery.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the fencing around the well.

1846768788 2017-04-20 Production Wells No Violations I was on location to assess compliance notice # --up line has a plug and the ball valve handle has been removed. The 210 bbl. storage tank is missing the required urban safety equipment. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9---site inspection. The tank battery is share with permits 2-3974 and 2-3975.

The equipment on the pad consists of the following:



Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0124366076 US-OH-106494 2016-08-04 ID (a-i)
0124366076 US-OH-106495 2016-08-04 LOCKS
0124366076 US-OH-106496 2016-08-04 TANKS (a-i)

For data sources see[9]

References