34-155-23996

Well Details

Well ID: 34-155-23996
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: LIBERTY BOARD OF EDUCATION
License Status: Producing
License Date: 2009-04-03
Spud Date: 2009-06-08
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2009-06-11
Well Total Depth: 5294.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -80.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-04-03 Proposed Formations:BEREA THRU MEDINA, Issued Date:4/3/2009, Expired Date:4/3/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2009-06-11
Completion Report Received 2009-08-25
Construction Permit Expires 2010-04-03
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-10 5056 5096 80
5056 5096 80
5056 5096 80

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2763 Bbl 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR 1045.00 89.00 36
2010 OHIO VALLEY ENERGY SYSTEMS COR 16963.00 285.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 8723.00 183.00 0
2012 OHIO VALLEY ENERGY SYSTEMS COR 8851.00 224.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 7841.00 170.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 5631.00 85.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 4754.00 90.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 2915.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 2414.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 3368.00 74.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 3515 36
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 291 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 275 0
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 145 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 130 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 56 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-560449553 2015-9-16 0:00: UP No Violations 1.00
0092290371 2017-07-19 UrbanProduction Wells No Violations

--up the impacted gravel and leaf litter in the tank battery.

The equipment on site:



0560449553 2015-09-16 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. There is a domestic gas line coming off of the wells 4.5 casing. The tank battery consists of a 100 barrel production tank, a 50 barrel, poly brine tank, a mechanical separator, and a Dominion meter run. There is a dike around the tank battery. Identification signs are posted. Urban safety equipment is installed on the tank. Locked, chain link fences with slats surround the well and tank battery. The lease road is in stable condition with a locked gate at the entrance.
0698665610 2012-10-25 UrbanPreliminary Restoration No Violations I completed an Urban Preliminary Restoration inspection. My inspection found the well equipped with a plunger lift unit surrounded by a chain link fence with slats and the proper identification. The tank battery was surrounded by a chain link fence with slats, the proper dike, and contained one, 100 barrel oil storage tank with the proper carbon filter, lightning arrestor, and low pressure relief valve, one, 50 barrel brine storage tank, a separator, and the proper identification. The production equipment had the correct spacing. I noticed no visible spills or leaks. The lease road had a gate at the entrance and was well maintained.
698665610 2012-10-25 0:00 UL No Violations 0.50
92290371 2017-7-19 0:00: UP No Violations 0.80

For data sources see[9]