If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-24011 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.18,"lon":-80.57,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: MARGALA | |
License Status: Producing | |
License Date: 2009-12-14 | |
Spud Date: 2010-01-21 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2010-01-26 | |
Well Total Depth: 5261.00 ft | |
Configuration: Vertical | |
Latitude: 41.180000 | |
Longitude: -80.570000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-12-14 | Proposed Formations:CLINTON/MEDINA, Issued Date:12/14/2009, Expired Date:12/14/2010 6:00:00 AM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-01-26 | |
Completion Report Received | 2010-06-01 | |
Construction Permit Expires | 2010-12-14 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-08-04 | 4980 | 5038 | 50 |
4980 | 5038 | 50 | |
4980 | 5038 | 50 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | PAC DRILLING LLC | 19252.00 | 441.00 | 286 |
2011 | PAC DRILLING LLC | 10119.00 | 327.00 | 346 |
2012 | PAC DRILLING LLC | 6464.00 | 299.00 | 308 |
2013 | PAC DRILLING LLC | 6378.00 | 371.00 | 365 |
2014 | PAC DRILLING LLC | 6653.00 | 111.00 | 360 |
2015 | PAC DRILLING LLC | 4950.00 | 176.00 | 360 |
2016 | PAC DRILLING LLC | 3805.00 | 60.00 | 357 |
2017 | PAC DRILLING LLC | 3145.00 | 56.00 | 357 |
2018 | PAC DRILLING LLC | 3643.00 | 59.00 | 358 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | PAC DRILLING LLC | Brine | 85 | 286 |
2011 | PAC DRILLING LLC | Brine | 0 | 346 |
2012 | PAC DRILLING LLC | Brine | 80 | 308 |
2013 | PAC DRILLING LLC | Brine | 0 | 365 |
2014 | PAC DRILLING LLC | Brine | 40 | 360 |
2015 | PAC DRILLING LLC | Brine | 40 | 360 |
2016 | PAC DRILLING LLC | Brine | 33 | 357 |
2017 | PAC DRILLING LLC | Brine | 0 | 357 |
2018 | PAC DRILLING LLC | Brine | 0 | 358 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1091339892 | 2010-3-25 0:00: | PL | No Violations | |
-1134307066 | 2017-2-28 0:00: | UP | No Violations | 0.70 |
-1288194409 | 2010-1-27 0:00: | DD | No Violations | |
-1489935346 | 2011-10-5 0:00: | UP | No Violations | |
-15287189 | 2019-10-22 0:00 | UP | No Violations | |
-1743708503 | 2011-10-5 0:00: | UP | No Violations | |
-1993955605 | 2016-8-2 0:00:0 | UP | No Violations | 0.30 |
-575405241 | 2012-4-9 0:00:0 | UP | No Violations | |
-753328053 | 2010-2-4 0:00:0 | DD | No Violations | |
0013367010 | 2010-02-16 | Drill / Deepen / Reopen | No Violations | Drilling pits showed no violations . |
0214699052 | 2018-05-21 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly, and the annulus and flow line valves were open. There was an identification posted on the well. There was no fencing around the well. The fencing was not waived during the pre-site inspection. The diked tank battery has four storage tanks and two separators. The pick-up lines have plugs and the handles on the valves have been removed. The required urban safety equipment has been installed on the production tanks. There was a locked chain link fence around the tank battery. The top of the production tanks extend more than 3 foot above the fence. An identification sign was posted on the fencing, but was missing the required information per 1501:9-9-05(E)(1)(a-e). There was no landscaping at the tank battery; however, the tank battery was located in a clearing approximately 700 feet from Route 7 and hidden behind a large commercial warehouse. The access road was stable with no gate at the entrance. The access road currently shares the entrance for a commercial warehouse and was not required during the pre-site inspection. The tank battery was shared with permit #2-4010. |
0558496413 | 2010-02-01 | Drill / Deepen / Reopen | No Violations | Drilling pits showed no violations . |
0575405241 | 2012-04-09 | UrbanProduction Wells | No Violations | My follow-up inspection of this well site found no identification. |
0753328053 | 2010-02-04 | Drill / Deepen / Reopen | No Violations | Service rig over well . Drilling pits showed no violations . |
1091339892 | 2010-03-25 | Preliminary Restoration | No Violations | Drilling pits have been closed . |
1134307066 | 2017-02-28 | UrbanProduction Wells | No Violations | I was on location to assess compliance notice # ----9-05(E)(1)(a--4010.
- PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9- The equipment on the pad consists of the following:
|
1288194409 | 2010-01-27 | Drill / Deepen / Reopen | No Violations | Company cementing production casing . |
1299934353 | 2012-08-09 | UrbanProduction Wells | No Violations | On 8/9/2012, I completed a follow-up inspection status check. My inspection found the proper identification had been posted at the tank battery and well. Inspection passed. |
13367010 | 2010-2-16 0:00: | DD | No Violations | |
1343660349 | 2012-07-30 | UrbanProduction Wells | Violations Noted | On 7/30/2012, I conducted an urban production well inspection status check. My inspection found the well was a plunger lift unit (rabbit) that was in good condition, but with no identification. The tank battery was shared with permit number 2-4010 and contained two 210 barrel oil storage tanks, two 50 barrel brine storage tanks, two separator, and no identification. The lease road was in good condition and shared with permit number 2-4010. I called Jason Caldwell of PAC Drilling at 330-340-6238 and asked for the tank battery and well to be proper identified by 8/10/2012. |
1447661360 | 2019-03-08 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 214699052, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, there was still no fencing around the well. The fencing was not waived during the pre-site inspection. The identification posted at the tank battery has been amended with the required information per 1501:9-9-05(E)(1)(a-e). The 210 BBL tank is taller than the tank battery fence. There was no landscaping at the tank battery; however, the tank battery was located in a clearing approximately 700 feet from Route 7 and hidden behind a large commercial warehouse.
PAC needs to: 1) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 2) Install the fencing around the well. |
1489935346 | 2011-10-05 | UrbanProduction Wells | Violations Noted | There was no identification. |
1743708503 | 2011-10-05 | UrbanProduction Wells | No Violations | FOLLOW UP TO NOV # -1489935346 There was no identification posted at this site. |
1773933116 | 2010-02-08 | Drill / Deepen / Reopen | No Violations | Drilling pits showed no violations . |
1926233820 | 2010-01-25 | Drill / Deepen / Reopen | No Violations | Capstar drilling company . Drilling pits showed no violations . |
1993955605 | 2016-08-02 | UrbanProduction Wells | Violations Noted
-4010. I spoke with Rusty Hornhill, well tender for PAC Drilling, concerning the identification sign, the missing locks and the required safety equipment. A compliance notice has been issued. PAC Drilling has 45 days to: Install the proper urban safety equipment.
Install locks on the load line ball valves on the production tanks. The equipment on the site consists of the following:
| |
214699052 | 2018-5-21 0:00: | UP | No Violations | |
558496413 | 2010-2-1 0:00:0 | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0214699052 | US-OH-122051 | 2018-06-06 | 9-05E1 | ID (a-i) |
0214699052 | US-OH-122052 | 2018-06-06 | 9-05E2 | FENCING (a-d) |
1343660349 | US-OH-109928 | 2012-07-30 | ID (a-i) | |
1489935346 | US-OH-113890 | 2013-04-22 | ID (a-i) | |
1993955605 | US-OH-120235 | 2017-07-17 | LOCKS | |
1993955605 | US-OH-120236 | 2017-07-17 | TANKS (a-i) |
For data sources see[9]