34-155-24013

Well Details

Well ID: 34-155-24013
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: CAPESTRO
License Status: Producing
License Date: 2009-12-14
Spud Date: 2010-01-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2010-01-12
Well Total Depth: 5291.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-12-14 Proposed Formations:CLINTON/MEDINA, Issued Date:12/14/2009, Expired Date:12/14/2010 6:00:00 AM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-01-12
Completion Report Received 2010-06-01
Construction Permit Expires 2010-12-14
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-08-03 5016 5080 48
5016 5080 48
5016 5080 48

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 46000 FLUID VOLUME OF FRAC NOT INDICATED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 PAC DRILLING LLC 23084.00 906.00 325
2011 PAC DRILLING LLC 11590.00 710.00 356
2012 PAC DRILLING LLC 5964.00 324.00 355
2013 PAC DRILLING LLC 4532.00 294.00 365
2014 PAC DRILLING LLC 4092.00 214.00 360
2015 PAC DRILLING LLC 3968.00 197.00 363
2016 PAC DRILLING LLC 2953.00 179.00 358
2017 PAC DRILLING LLC 2636.00 157.00 359
2018 PAC DRILLING LLC 2855.00 101.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 PAC DRILLING LLC Brine 163 325
2011 PAC DRILLING LLC Brine 175 356
2012 PAC DRILLING LLC Brine 70 355
2013 PAC DRILLING LLC Brine 44 365
2014 PAC DRILLING LLC Brine 22 360
2015 PAC DRILLING LLC Brine 22 363
2016 PAC DRILLING LLC Brine 25 358
2017 PAC DRILLING LLC Brine 0 359
2018 PAC DRILLING LLC Brine 20 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1366998367 2020-9-4 0:00:0 UP No Violations
-1618130671 2020-3-31 0:00: UP No Violations
-957895965 2018-5-11 0:00: UP No Violations
0214494441 2016-01-21 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery has three, 210 barrel production tanks, two, 50 barrel, poly brine tanks and two, mechanical separators. There is a dike around the tank battery. Identification signs are posted at the well and tank battery. A locked, chain link fence surrounds the tank battery. The lease road is in stable condition. The tank battery is shared with permit number 2-4014 and 2-4012.
0277042445 2017-02-15 UrbanProduction Wells No Violations

---9--e). There is no landscaping at the tank battery; however, the tank battery and private residences are separated by a line of brush and trees. The access road is in good repair. The access road gate was not waived during the pre-site inspection. The tank battery and access road is shared with permit #2-4012 and #4-4014.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. -up lines per 1501:9-9- 3) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9- 4) Repair the small gas leak at the well. 5) Install a locked gate at the access road entrance and post the proper identification sign per 1501:9-9-0

0653473299 2010-02-01 Preliminary Restoration No Violations Drilling pits have been closed . No violations .
0688703641 2010-01-12 Drill / Deepen / Reopen No Violations Capstar TD at 5291 , laying down drill string . Drilling pits showed no violations .
0957895965 2018-05-11 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted at the well, but no fence was installed around the well. The diked tank battery has three 210 BBL tanks, one 50 BBL tank and two mechanical separators. The pick-up lines are secure with the valve handles removed and plugs. The production tanks have the required urban safety equipment. There was a locked chain link fence surrounding the tank battery, with 3 strand barb at the top. The identification sign was missing the required information. No landscaping was installed around the tank battery. The tank battery was shared with wells 2-4012 and 2-4014. The access was stable. The required access gate was installed and needs a lock.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 3) Complete the required landscaping around the tank battery per 1501:9-9-05(E)(6)(a-c). 4) Install the required fencing with a lock around the wellhead per 1501:9-9-05(E)(2).

0966961313 2013-03-05 UrbanProduction Wells No Violations My inspection found the proper identification sign posted at the tank battery and well. The safety equipment was installed on the production tank.
1161221294 2010-01-27 Preliminary Restoration No Violations Drilling pits showed no violations .
1477878020 2019-02-25 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 957895965, regarding the installation of identification at the road access gate and required lock on the gate, amended identification information at the tank battery, and install landscaping at the tank battery location, and fencing around the well. At the time of this inspection, the access gate identification and lock has been installed. The other above items have not been addressed.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Complete the required landscaping around the tank battery per 1501:9-9-05(E)(6)(a-c). 4) Fencing needs installed around the well.

214494441 2016-1-21 0:00: UP No Violations 0.50
277042445 2017-2-15 0:00: UP No Violations 0.60
653473299 2010-2-1 0:00:0 PL No Violations
688703641 2010-1-12 0:00: DD No Violations
966961313 2013-3-5 0:00:0 UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0957895965 US-OH-130941 2018-06-05 9-05E1 ID (a-i)
0957895965 US-OH-130942 2018-06-05 9-05E2 FENCING (a-d)
0957895965 US-OH-130943 2018-06-05 9-05E6 LANDSCAPING (a-c)

For data sources see[9]