34-155-24029

Well Details

Well ID: 34-155-24029
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bristol Township
Operator Name: CEDAR VALLEY ENERGY INC
Well Pad ID:
Farm/Lease Name: KING REX
License Status: Producing
License Date: 2010-08-25
Spud Date: 2010-10-18
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2010-10-22
Well Total Depth: 4266.00 ft
Configuration: Vertical
Latitude: 41.370000
Longitude: -80.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-08-25 Proposed Formations:CLINTON, Issued Date:8/25/2010, Expired Date:8/24/2012 12:00:00 PM, Drilling unit acres:40.3, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-10-22
Completion Report Received 2011-01-04
Construction Permit Expires 2012-08-24
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-05-05 4042 4083 27
4042 4083 27
4042 4083 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-11-03 H2O 15 95000 Gal 58000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 CEDAR VALLEY ENERGY INC 6392.00 866.00 365
2012 CEDAR VALLEY ENERGY INC 3503.00 468.00 366
2013 CEDAR VALLEY ENERGY INC 2088.00 328.00 365
2014 CEDAR VALLEY ENERGY INC 1600.00 319.00 365
2015 CEDAR VALLEY ENERGY INC 1350.00 222.00 365
2016 CEDAR VALLEY ENERGY INC 1578.00 304.00 365
2017 CEDAR VALLEY ENERGY INC 1682.00 203.00 365
2018 CEDAR VALLEY ENERGY INC 1408.00 215.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 CEDAR VALLEY ENERGY INC Brine 1025 365
2012 CEDAR VALLEY ENERGY INC Brine 668 366
2013 CEDAR VALLEY ENERGY INC Brine 451 365
2014 CEDAR VALLEY ENERGY INC Brine 392 365
2015 CEDAR VALLEY ENERGY INC Brine 380 365
2016 CEDAR VALLEY ENERGY INC Brine 469 365
2017 CEDAR VALLEY ENERGY INC Brine 367 365
2018 CEDAR VALLEY ENERGY INC Brine 179 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1842751593 2013-8-28 0:00: PW No Violations 0.50
-2114399842 2011-6-29 0:00: PL No Violations
0103998125 2019-03-13 Production Wells No Violations At the time of this inspection, the well was equipped with a pumping unit. The valve on the tubing was open and 2 inch flow line was open. The diked tank battery consisted of one 100 BBL tank, one 50 BBL steel tank, and a mechanical separator. Valves on the separator were open and the chart showed production. Legible identification was present at the well and tank battery and the lease access was stable. No violations observed.
0143728121 2015-11-16 Production Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a pumpjack. The tank battery consists of a 100 barrel production tank, a 50 barrel brine tank, and a mechanical separator. A dike surrounds the tank battery. There is an identification sign posted. There is a plug on the load line. The lease road is in good repair.
103998125 2019-3-13 0:00: PW No Violations 0.40
143728121 2015-11-16 0:00 PW No Violations 0.50
1497964842 2017-06-20 Production Wells No Violations

-up lines have plugs. The access road is in good repair.

The equipment on site:



1530214495 2018-06-28 Production Wells No Violations At the time of this inspection, the well was equipped with a pumping unit and the valve on the tubing was open. The 2 inch flow line valve was open. Production records for this well were current. The tank battery consisted of one 100 BBL tank, one 50 BBL steel tank, and a mechanical separator. Valves on the separator were open and the chart showed production. The tank battery was diked and had legible signage. The lease access was stable. No violations observed.
1656691118 2013-07-31 Production Wells No Violations My inspection found the well in production. The well was equipped with a pumping unit. The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator. The proper identification sign was posted on the production tank. There were plugs on the load lines. The dike meets containment requirements. There was water inside the dike with an approximate 2-3 depth at the north end that thinned out towards the south of the tank battery. I noticed a stretch of orange tinted water on the outside of the dike located at the north end of the tank battery. The grass in that area was partially dead. I sampled the water with one low level and one high level Quantab. The result was a 6.2 on the low level that comes out to 363 parts/million and a 2.8 on the high level that comes out to 396 parts/million. The pH read 8. Photos of the area were taken. I sampled the water inside the dike using a low level Quantab. My result was a 4 that comes out to 161 parts/million. I called Tim Cosma, Cedar Valley supervisor, and informed him of my findings. I instructed Tim to clean-up the affected area.
1842751593 2013-08-28 Production Wells No Violations My inspection found the affected area with the orange tinted water on the outside of the dike at the north end of the tank battery cleaned up per my request. The area was graded with clean soil. New photos were taken.
2114399842 2011-06-29 Preliminary Restoration No Violations Preliminary restoration was completed and meets requirements.

For data sources see[9]

References