34-155-24034

Well Details

Well ID: 34-155-24034
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: WALKER
License Status: Producing
License Date: 2010-12-21
Spud Date: 2011-01-02
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2011-01-08
Well Total Depth: 5337.00 ft
Configuration: Vertical
Latitude: 41.190000
Longitude: -80.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-12-21 Proposed Formations:CLINTON-MEDINA, Issued Date:12/21/2010, Expired Date:12/20/2012 12:00:00 PM, Drilling unit acres:45.0206, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-01-08
Completion Report Received 2011-10-12
Construction Permit Expires 2011-12-21
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-29 5020 5100 24
5020 5100 24
5020 5100 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-01-12 H2O 20 132700 Gal 30000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 PAC DRILLING LLC 16304.00 1120.00 319
2012 PAC DRILLING LLC 14048.00 795.00 324
2013 PAC DRILLING LLC 13058.00 444.00 357
2014 PAC DRILLING LLC 12352.00 387.00 347
2015 PAC DRILLING LLC 10501.00 318.00 360
2016 PAC DRILLING LLC 7396.00 279.00 359
2017 PAC DRILLING LLC 6475.00 320.00 359
2018 PAC DRILLING LLC 6395.00 246.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 PAC DRILLING LLC Brine 61 319
2012 PAC DRILLING LLC Brine 32 324
2013 PAC DRILLING LLC Brine 0 357
2014 PAC DRILLING LLC Brine 0 347
2015 PAC DRILLING LLC Brine 80 360
2016 PAC DRILLING LLC Brine 0 359
2017 PAC DRILLING LLC Brine 0 359
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1468794980 2015-3-25 0:00: UP No Violations 0.50
-2010113860 2020-4-24 0:00: UP No Violations
-29348256 2016-11-7 0:00: UP No Violations 0.70
-52427417 2019-2-28 0:00: UP No Violations
-882878292 2018-5-15 0:00: UP No Violations
0029348256 2016-11-07 UrbanProduction Wells No Violations

-3964. I spoke with Rusty Hornhill while on site.

PAC Drilling will: Install locks on the load lines or remove the valve handles Install the required safety equipment


-pressure relief valve


The equipment on the site consists of the following:



0052427417 2019-02-28 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1151635343. At the time of this inspection, the fence still needs installed around the well. The fencing at the well was not waived on the pre-site inspection. The required urban safety equipment was missing from both production tanks and needs installed. An identification sign was posted at the tank battery but needs amended with the required information per 1501:9-9-05(E)(1)(a-e). There was no fencing surrounding the tank battery. The fencing was not waived during the pre-site inspection. The access gate has had a lock installed and identification posted on the gate.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install the required urban safety equipment per 1501:9-9-05(E)(4)(a-e): Activated charcoal filter. Functioning low-pressure relief valve. Tank hatch shall have a functioning seal and the hatch shall be secure at all times. Functioning lightning arrestor. 3) Install the fencing around the well.

0092711845 2011-09-14 Preliminary Restoration No Violations Preliminary Restoration was completed.
0491419947 2012-08-16 UrbanProduction Wells No Violations On 6/16/2012, I completed an urban production well inspection status check. This well shares a lease road and tank battery with permit number 2-3964. My inspection found the well was equipped a plunger lift unit (rabbit) that was in good condition. The tank battery contained two 210 barrel oil storage tanks, two 50 barrel brine storage tanks, two separators, and the proper identification posted. I noticed no visible spills or leaks. The lease road was in good condition. There are no violations at this time.
0882878292 2018-05-15 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1151635343. The well was equipped with a plunger lift assembly, and the annulus and flow line valves were open. There was an identification posted at the well but no fence has been installed around the well. The fencing at the well was not waived on the pre-site inspection. The well was located approximately 600 feet from nearest private residence in a clearing along high electrical power lines, and not visible from Chestnut Ridge Road. The diked tank battery has four storage tanks and two separators. The pick-up lines are secure with plugs and the handles have been removed. The required urban safety equipment was missing from both production tanks. An identification sign was posted at the tank battery. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). There was no fencing surrounding the tank battery. The fencing was not waived during the pre-site inspection. The tank battery is surrounded on three sides by trees and vegetation and not visible from Chestnut Ridge Road or private residences. The access road was stable with a gate near the entrance. There was no lock or identification posted on the gate. The tank battery is shared with permit #2-3964.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install the required urban safety equipment per 1501:9-9-05(E)(4)(a-e): Activated charcoal filter. Functioning low-pressure relief valve. Tank hatch shall have a functioning seal and the hatch shall be secure at all times. Functioning lightning arrestor. 3) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f).

1118287396 2017-10-10 UrbanProduction Wells Violations Noted

--up lines are secure with plugs and the handle have been removed from the valves. The required urban safety equipment is missing from both production tanks. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is no fencing surrounding the tank battery. The fencing was not waived during the pre-site inspection. The tank battery is surrounded by trees and vegetation and not visible from Chestnut Ridge Road or private residences. The access road is in good repair with a gate near the entrance. There is no lock and no identification posted on the gate. The tank battery is shared with permit #2-3964.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install the required urban safety equipment on both production tanks as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning

1468794980 2015-03-25 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consisted of two (2), 210 barrel production tanks, two (2), poly, 50 barrel brine tanks and two (2), mechanical separators. A dike surrounded the tank battery. Identification signs are posted. The lease road is in stable condition with a locked gate at the entrance.
1743968719 2017-03-09 UrbanProduction Wells No Violations

--up lines have plugs, but no locks. The required urban safety equipment is missing from both production tanks. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is no fencing surrounding the tank battery. The fencing was not waived during the pre-site inspection. The tank battery is surrounded by trees and vegetation and not visible from Chestnut Ridge Road or private residences. The access road is in good repair with a gate near the entrance. There is no lock and no identification posted on the gate. The tank battery is shared with permit #2-3964.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install the required urban safety equipment on both production tanks as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install a loc

491419947 2012-8-16 0:00: UP No Violations 0.50
92711845 2011-9-14 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1118287396 US-OH-102994 2017-12-26 ID (a-i)
1118287396 US-OH-102995 2017-12-26 LOCKS
1118287396 US-OH-102996 2017-12-26 TANKS (a-i)

For data sources see[9]