X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-24054

Well Details

Well ID: 34-155-24054
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: P.A.C.
License Status: Producing
License Date: 2012-07-24
Spud Date: 2012-07-31
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2012-08-21
Well Total Depth: 5455.00 ft
Configuration: Vertical
Latitude: 41.180000
Longitude: -80.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-05 Proposed Formations:CLINTON-MEDINA, Issued Date:3/5/2012, Expired Date:3/5/2014 12:00:00 PM, Drilling unit acres:105.39, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2012-07-24 Proposed Formations:CLINTON/MEDINA, Issued Date:7/24/2012, Expired Date:7/24/2014 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2012-08-02 ADDED SPECIAL PERMIT CONDITION: "WAIVER ON FLUID DRILLING REQUIREMENT AND FENCING".
Reached Total Depth 2012-08-21
Completion Report Received 2013-03-04
Construction Permit Expires 2013-07-24
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-03-05 5180 5338 50
5180 5338 50
5180 5338 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-08-10 H2O 20 3221 Bbl 50000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 PAC DRILLING LLC 8405.00 439.00 129
2013 PAC DRILLING LLC 15341.00 537.00 365
2014 PAC DRILLING LLC 12127.00 263.00 360
2015 PAC DRILLING LLC 10389.00 201.00 360
2016 PAC DRILLING LLC 7669.00 89.00 356
2017 PAC DRILLING LLC 6453.00 153.00 357
2018 PAC DRILLING LLC 6330.00 88.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 PAC DRILLING LLC Brine 51 129
2013 PAC DRILLING LLC Brine 0 365
2014 PAC DRILLING LLC Brine 41 360
2015 PAC DRILLING LLC Brine 46 360
2016 PAC DRILLING LLC Brine 0 356
2017 PAC DRILLING LLC Brine 0 357
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1028395376 2012-8-16 0:00: UP No Violations 0.50
-269760290 2019-3-8 0:00:0 UP No Violations
-634522266 2012-7-30 0:00: UD No Violations 0.50
0112108651 2012-08-09 Urban Drill / Deepen / Reopen No Violations On 8/9/2012, I conducted an inspection of the newly drilled well. Appalachian Well Survey had perforated the well with a top shot at 5,180 and bottom shot at 5,338.
0269760290 2019-03-08 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1073749539, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the identification posted at the tank battery has been amended with the required information per 1501:9-9--e). No fencing has been installed around the well or tank battery, however the pre-site inspection references the entire site be fenced. Miscellaneous equipment was on site, i.e. old paint cans inside of diked tank battery need removed. The access road gate has not been installed at the entrance. The access road gate was not waived during the pre-site inspection.

PAC needs to: 1) Cleanup the debris and miscellaneous parts within the tank battery. 2) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 3) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 4) Install fencing around the entire site.

0293864764 2014-07-08 UrbanPreliminary Restoration No Violations I was on location for a urban preliminary restoration. I found during my inspection the well in production with a plunger lift unit. The tank battery consisted of a 210 barrel production tank, a 50 barrel, poly brine tank and a separator. A dike surrounded the production equipment. Identification signs were posted at the well and tank battery. A bull plug was installed on the load line. Safety equipment was properly installed on the production tank. The fencing was waived, because the well and tank battery were located in a wooded and isolated area. The lease road was in good condition. The site was graded. Vegetation was well established. The pits were closed and filled. All debris was removed. Drainage and erosion controls were in place and working properly.
0634522266 2012-07-30 Urban Drill / Deepen / Reopen No Violations On 7/30/2012 at 8:30 AM, I conducted a site visit on the construction progress for the well site. I was informed by Jason Caldwell of PAC Drilling that the Wild Cat Rig would be moving onto location today.
1028395376 2012-08-16 UrbanProduction Wells No Violations On 8/16/2012, my inspection of the pits found them still open.
1073749539 2018-05-17 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. An identification sign was posted at the well. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs and the handles have been removed. The 210 BBL storage tank has the required urban safety equipment. An identification sign was posted at the tank battery, but was missing the required information per 1501:9-9--e). No fencing has been installed around the well or tank battery, however the pre-site inspection references the entire site be fenced. Miscellaneous equipment was on site, i.e. pump jack frame, rods, old paint cans inside of diked tank battery, and need removed. The access road was stable, but no gate has been installed at the entrance. The access road gate was not waived during the pre-site inspection. Landscaping was waived due to the wellsite location.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 3) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 4) Install fencing around the entire site.

112108651 2012-8-9 0:00:0 UD No Violations 1.00
1345811370 2012-08-23 Urban Drill / Deepen / Reopen No Violations My inspection found the pits were closed and the site was graded.
1469105177 2016-07-21 UrbanProduction Wells Violations Noted


PAC Drilling has one week to: Install a lock on the load line.

The equipment on the site consists of the following:



1494513556 2017-03-29 UrbanProduction Wells No Violations

-up lines have plugs but no locks. The 210 bbl. storage tank has the required urban safety equipment. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9--e). There is a danger, keep out and no smoking sign(s) posted. There is no fencing around the well or tank battery. Fencing was not waived during the pre-site inspection. The access road is in good repair with no gate at the entrance. The access road gate was not waived during the pre-

The equipment on the pad consists of the following:



1819452743 2017-12-18 UrbanProduction Wells No Violations I found the well in production. The proper urban safety equipment has been installed on the production tank. The handles have been removed from the pick-up lines. PAC still needs to:

Install the require gate with a lock at the access road entrance. Post the proper identification sign on the access road gate.

1821643787 2020-3-27 0:00: UP No Violations
293864764 2014-7-8 0:00:0 UL No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1073749539 US-OH-101557 2018-06-11 ID (a-i)
1073749539 US-OH-101558 2018-06-11 FENCING (a-d)
1073749539 US-OH-101559 2018-06-11 General Safety
1469105177 US-OH-113500 2016-08-04 LOCKS

For data sources see[9]

References