X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-24063

Well Details

Well ID: 34-155-24063
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Greene Township
Operator Name: AMERICAN ENERGY ASSOCIATES INC
Well Pad ID:
Farm/Lease Name: JOHNSON DISPOSAL (SWIW # 23)
License Status: Active Injection
License Date: 2013-05-08
Spud Date: 2013-03-04
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2013-03-11
Well Total Depth: 7735.00 ft
Configuration: Vertical
Latitude: 41.460000
Longitude: -80.720000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-01-17 Proposed Formations:MT. SIMON SANDSTONE, Issued Date:1/17/2013, Expired Date:1/17/2015 12:00:00 PM, Drilling unit acres:5.318, Proposed Well Type:SWD, Proposed Well Class:SWIW
Reached Total Depth 2013-03-11 DeepestFMTN agrees with DGS-reference PG-2
Completion Report Received 2013-03-18 DeepestFMTN agrees with DGS-reference PG-2
APP 2013-05-08 Proposed Formations:KNOX THRU MT. SIMON, Issued Date:5/8/2013, Expired Date:5/8/2015 12:00:00 PM, Drilling unit acres:5.318, Proposed Well Type:SWD, Proposed Well Class:SWIW
Last Compliance Report 2013-05-08 DeepestFMTN agrees with DGS-reference PG-2
Record Last Modified 2014-09-25 DeepestFMTN agrees with DGS-reference PG-2
Construction Permit Expires 2015-05-08 DeepestFMTN agrees with DGS-reference PG-2

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-08-06 6669 8300 0
6669 8300 0
6669 8300 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1036421064 2020-3-3 0:00:0 SW No Violations
-1080990857 2020-3-2 0:00:0 SW No Violations
-1155489638 2017-3-13 0:00: SW No Violations
-1264518418 2013-2-27 0:00: DD No Violations
-1311822063 2018-10-16 0:00 SW No Violations 1.40
-1320756484 2019-2-11 0:00: SW No Violations 1.00
-1321193399 2015-2-26 0:00: SW No Violations
-1415548345 2018-2-28 0:00: PW No Violations 2.00
-1421693618 2018-3-6 0:00:0 SW No Violations 1.50
-1423995148 2020-5-18 0:00: SW No Violations 1.00
-146935849 2013-2-27 0:00: DD No Violations
-1474497188 2017-1-23 0:00: SW No Violations
-1493574740 2014-9-4 0:00:0 SW No Violations
-1524907369 2019-8-22 0:00: SW No Violations 2.00
-1545126321 2015-7-14 0:00: SW No Violations
-1628265734 2015-7-29 0:00: SW No Violations
-1734459897 2020-3-30 0:00: SW No Violations 1.00
-174072338 2014-12-10 0:00 SW No Violations
-1809346343 2017-2-21 0:00: SW No Violations
-1897425764 2015-2-13 0:00: SW No Violations
-2030842654 2014-3-17 0:00: SW No Violations
-2116392528 2014-10-14 0:00 SW No Violations
-311261054 2020-2-25 0:00: SW No Violations 1.30
-34572582 2020-7-29 0:00: SW No Violations 1.00
-349052487 2016-2-29 0:00: SW No Violations
-353362374 2015-6-16 0:00: SW No Violations
-555630561 2019-2-11 0:00: SW No Violations
-612077095 2020-8-26 0:00: SW No Violations 1.50
-630830688 2015-3-25 0:00: SW No Violations
-674440751 2015-5-6 0:00:0 SW No Violations
-815381795 2020-3-16 0:00: SW No Violations
-861885674 2015-12-21 0:00 SW No Violations 1.00
-920141282 2020-4-23 0:00: SW No Violations 0.90
-94636837 2018-8-13 0:00: SW No Violations 1.30
-959437329 2017-2-28 0:00: SW No Violations
-962503428 2018-2-8 0:00:0 SW No Violations 0.80
-969688261 2017-10-26 0:00 SW No Violations 0.50
0066034713 2017-06-05 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time of inspection.
0080502911 2013-03-20 Drill / Deepen / Reopen No Violations The pits were in good condition. There were no violations at the time of my inspection.
0094636837 2018-08-13 Salt Water Injection Well No Violations I was on location to assess compliance notice #1519910174. I found the site secure with a locked access road gate. The pump house and office are locked. All of the water has been removed from within the diked tank battery. There are numerous saturated absorbent pad and old oil clumps throughout the dike. There is a pool of oil in the southeast corner of the dike around and in the sump crock.

American Energy still needs to: Remove and properly dispose of the saturated absorbent pads. Rack up and properly dispose of the oil clumps. Remove the pool of oil in the southeast corner of the dike.

0133667642 2016-08-01 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0146935849 2013-02-27 Drill / Deepen / Reopen No Violations I witnessed a pressure test of the conductor with 220 psi. of pressure. The pressure dropped to 198 psi., after a 30 minute test period. The test passed with a ten percent loss.
0174072338 2014-12-10 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was operating at the time. A tanker truck, owned by Bessemer Supply, was unloading. There were no violations found.
0205032581 2013-02-26 Drill / Deepen / Reopen No Violations My inspection found the well site to be under construction. The drainage barrier was in good condition. Talked to the equipment operator to have the silt barrier continued further up towards the road to block anything from running off the location and into the creek below the location. The pits were also in the process of being constructed. The pit walls were constructed at a proper angle.
0215764318 2016-08-30 Salt Water Injection Well No Violations The injection well and surface facility were inspected. A sample of the filtered water had a specific gravity of 1.16. There were no violations found at the time.
0234180965 2018-09-18 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found the water has been pumped down inside of the diked tank battery. There still is oil and a small amount of water at the south end of the tank battery. The sump crock in the southeast corner of the tank battery is full of oil. The entire tank battery has saturated absorbent pads. There is a chart box and 7-day chart dated 9/16/2018 next to the northwest corning of the tank battery. There is an identification sign posted. The gate at the access road entrance is locked. The pump house/office is locked and secure. Photos were taken and are available upon request. I left a message with Bob Barnett concerning this compliance notice.
0332838795 2015-09-04 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0349052487 2016-02-29 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The well was not in use at the time. There were no violations found.
0353362374 2015-06-16 Salt Water Injection Well No Violations The injection pressure was below the maximum allowed. The 1/4 inch valve on the tubing was replaced. There was positive pressure on the tubing-casing annulus.

The well was in compliance.

0381616012 2017-02-09 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
0382234199 2018-03-19 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found no one on location with a locked access road gate. There is still oil floating on top of water in the dike. The water at the northern part of the dike is frozen. The oil is contained within the dike. Photos were taken and are available upon request.
0505303756 2013-02-28 Drill / Deepen / Reopen No Violations I witnessed the installation and cementing of the surface casing. The bore hole was 11 inches in diameter and drilled 1047 feet deep. A total of 1016 feet of 8-5/8 inch casing was cemented with 340 sacks of Class-A cement with 3% calcium chloride. Estimated cement returns of 20 barrels were observed at the surface. Once the plug was down, the pressure on the casing was increased to 500 psi.. There was no pressure loss, after five minutes. The cement operation and well site conditions were acceptable.
0553471574 2018-11-15 Salt Water Injection Well No Violations I was on location to assess Compliance Notice # -1415548345. I found the injection well not in operation. There was no facility operator on location. Identification signs are posted. The facility is secure with a closed and locked gate. The office/pump house is locked. Numerous saturated absorbent pads are still throughout the entire diked tank battery. I observed water and oil with leaf litter at the south end of the diked tank battery near the sump crock. The water and oil are contained to the dike.

I spoke with Bob Barnett: Mr. Barnett stated the facility is taking some fluid. Mr. Barnett stated he is still working on cleaning up the oil and saturated absorbent pads in the dike.

I told Mr. Barnett that the oil and saturated absorbent pads need cleaned up and removed. Photos have been taken and are available upon request.

0555630561 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
0623078964 2018-07-18 Salt Water Injection Well No Violations I was on location to assess Compliance Notice # -1415548345. I found the owner, Bob Barnett, on location. There was still oil residue inside of the diked tank battery with several inches of water. There were new and saturated absorbent pads throughout the dike. The injection well was not in operation during my inspection. The water and oil are contained inside of the dike. An identification sign is posted. The pump house is clean and in good repair. Mr. Barnett stated he was working on acquiring a diaphragm pump to remove all of the water and oil. Mr. Barnett stated having the dike cleaned up by next week. Follow-up inspections will continue.
0630830688 2015-03-25 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0662689640 2014-05-06 Salt Water Injection Well No Violations The buried tank was coated on the inside with a brine resistant material. All construction conditions have been met.
0674440751 2015-05-06 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
0676547517 2015-06-15 Salt Water Injection Well Violations Noted An inspection found the well injection pressure exceeding the maximum allowed. The 1/4 inch valve on the tubing was stuck shut.

Robert Barnett was instructed to suspend injection operation, replace the stuck valve, pressurize the tubing-casing annulus, and set the pressure shut-off switch to 1540 pounds per square inch.

0711028997 2016-12-29 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was operating at the time. The tanks and lines had no visible leaks.

There were no violations found.

0732693169 2013-03-11 Drill / Deepen / Reopen No Violations I witnessed the cementing of the long string. 6669 feet of 5-5/8 inch casing was cemented in a 7-7/8 inch hole, drilled to a total depth of 7735 feet. A total of 780 sacks of class-A cement was pumped in two stages. Conditions of the well site and cement operation were acceptable.
0758777040 2016-03-17 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0816185168 2013-05-10 Salt Water Injection Well No Violations I witnessed the initial mechanical integrity test.

Five gallons of corrosion inhibitor were mixed with 100 barrels of fresh water and pumped down the tubing-casing annulus. Approximately five barrels were circulated into the work-over pit.

A pressure of 1880 psi. was placed on the tubing-casing annulus. During a fifteen minute test period, there was no loss detected.

The well passed the test.

0861885674 2015-12-21 Salt Water Injection Well No Violations I was on location to inspect the injection well and facility. At this time, there are no violations.
0959437329 2017-02-28 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 3rd & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017. Disposal fees and fee reports received 7/13/2017
0962503428 2018-02-08 Salt Water Injection Well No Violations I was on location to inspect the UIC well and facility. I found the well not in operation on the day of my inspection. I found no spills or leaks. The proper identification signs are posted. The facility is secure with a locked gate at the access road entrance. There are no violations at this time.
0969688261 2017-10-26 Salt Water Injection Well No Violations I was on location to inspect the injection well. The tank battery is in good repair. The proper identification is posted at the facility. I gauged the tubing and annulus and obtained similar readings. I told the facility operator to add pressure to the backside and a follow-up inspection will be conducted by Nov. 1, 2017.
1017598360 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. fees and reports received 5/9/2018
1088505086 2017-05-03 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1144118962 2013-04-29 Salt Water Injection Well No Violations There was nobody on location. My inspection of the well site found no violations.
1146717011 2013-03-07 Drill / Deepen / Reopen No Violations The rig was drilling on fluid at 6808 feet. All conditions were acceptable.
1155489638 2017-03-13 Salt Water Injection Well No Violations An inspection of the injection well and surface facility found no violations.
1252853301 2018-03-28 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found Bob Barnett on location. There are still several inches of water with oil in the steel diked tank battery. All of the water and oil is contained to the dike. I observed numerous saturated absorbent pads along with several fresh absorbent pads throughout the dike. Mr. Barnett stated he is working on getting the water and oil removed. Follow-up inspections will continue. Photos were taken and are available upon request.
1264518418 2013-02-27 Drill / Deepen / Reopen No Violations I witnessed the installation and cementing of an 11-3/4 inch conductor. Holes were cut in the bottom of the casing. A total string of 306 feet was set on the bottom of a 14-3/4 inch hole, 301 feet deep. The conductor was cemented with 250 sacks of Class-A cement with 3% calcium chloride. Estimated cement returns of 25 barrels were observed at the surface. The displacement was calculated to leave 20 feet of cement in the casing. The cement operation and well site conditions were acceptable.
1311822063 2018-10-16 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found the injection well not operating on the day of my inspection. There are still numerous saturated absorbent pads throughout the diked tank battery. There are pools of oil at the south end of the diked tank battery. There is oil in the sump crock located in the southeast corner of the dike. An identification sign is posted. The facility office and pump house are locked. The access road gate is locked. Photos have been taken and are available upon request.

American Energy still needs to: Remove the pools of oil in the dike Remove and properly disposed of the saturated absorbent pads

I left a message with Bob Barnett concerning the compliance notice.

1316374052 2016-07-14 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1320756484 2019-02-11 Salt Water Injection Well No Violations I was on location to assess Compliance Notice # -1415548345. I found the injection well in operation during my inspection. There was a facility operator on location. Most of the oil spill in the dike tank battery has been cleaned up. There is still a small amount of oil and several absorbent pads to be removed. The facility operator stated he is still working on getting the tank battery cleaned. Follow-up inspections will continue.
1321193399 2015-02-26 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The annulus was frozen. There were no violations found at the time.
133667642 2016-8-1 0:00:0 SW No Violations
1345110758 2016-08-05 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1345483197 2019-5-1 0:00:0 SW No Violations 1.20
1363019800 2013-03-04 Drill / Deepen / Reopen No Violations On 03/04/2013, North East Regional Supervisor and myself was on location. Advents Drilling rig had drilled to 4320. They were tripping out to change the drill bit to a PDC. The permit was posted. The pit were close to the top and they were in the process of hooking up their pumps to pump it into a frac tank.
1364926203 2013-04-02 Drill / Deepen / Reopen No Violations The drilling pits were being solidified. The operation appeared to be halfway completed. No one was on site at the time. All conditions were acceptable.
1365107321 2013-04-04 Drill / Deepen / Reopen No Violations The contractor was covering solidified pit with topsoil. One pit (surface pit) remains to be solidified. All conditions were acceptable.
1365289341 2020-5-6 0:00:0 SW No Violations
1371826261 2013-06-20 Salt Water Injection Well No Violations A nuclear tracer log was ran in the well.
1372534608 2013-06-27 Surface Facility Construction No Violations Work started on the pump house. There were no violations found at the time of inspection.
1384281631 2013-11-12 Salt Water Injection Well No Violations The well owner was conducting a fall-off test. There was 180 psi. on the tubing surface, while pumping at 2 barrels per minute. All conditions were acceptable.
1404747008 2014-04-23 Salt Water Injection Well No Violations The construction of the surface facility was complete. A gate was installed at the access. Both sump pumps were plumbed into a tank. The injection facility design matches the specifications of the revised plan approved by the Division. However, the buried tank was not coated with a brine resistant material, which is a permit condition. I called Bob Barnett and informed him of the requirement.
1415548345 2018-02-28 Production Wells Violations Noted I was on location to inspect the injection well and facility. I found no activity on the day of my inspection. The gate at the access road entrance is locked. The proper identification sign is posted. Upon further inspection, I found several inches of standing water topped with oil and an oily sheen throughout the lined, steel diked tank battery. The oil spill is contained within the dike. The oil spill appears to originate from the middle 210 bbl. storage tank. The injection well was not in operation. The gate valve on the tubing is open. There is leaf litter and old oil at the bottom of the pit surrounding the wellhead. I contacted Bob Barnet from American Energy.

Mr. Barnet stated: Clean up of the oil spill would starts as soon as possible.

I instructed Mr. Barnet to: Remove all oil and water from the diked tank battery Clean up and proper dispose of the old oil and leaf litter at the bottom of the pit surrounding the wellhead.

Follow-up inspections will be conducted until all the issues are corrected. Photos have been taken and are available upon request.

1421693618 2018-03-06 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found some of the water in the diked tank battery has been pump down. There is still oil on top of the water mainly on the east and southeastern areas of the dike. Absorbent pads have been placed inside the dike and in the pit with the wellhead. Majority of the water and oil in the dike was frozen due to the cold temperatures. Bob Barnet was on location working on the injection pump.

Mr. Barnet state: Clean-up of the diked tank battery has begun; however, clean-up has been hindered due to the weather with the snow and freezing temperatures.

Follow-up inspections will continue until all issues are corrected. Photos have been taken and are available upon request.

1463677127 2016-05-19 Salt Water Injection Well Violations Noted


- Set the pressure shut-off switch to 1540 psi. - Remove and properly dispose of the oil, leaf litter and absorbent pad in the cellar.

Mr. Day was informed a compliance notice will be issued for exceeding maximum allowable pressure. Photos have been taken and are available upon request.

1463767376 2016-05-19 Salt Water Injection Well No Violations I was on location in reference to compliance notice #1463677127. At the time of my inspection, I found the injection well not in operation. Bob Barnett, owner of the facility and Don Day, facility operator were cleaning the oil and leaf litter from the cellar at the well. The pressure shut-off switch in the pump house has been set to 1540 psi.
1474497188 2017-01-23 Salt Water Injection Well No Violations An inspection of the injection well and surface facility found no violations.
1479606926 2019-7-11 0:00: SW No Violations 1.40
1493574740 2014-09-04 Salt Water Injection Well No Violations An inspection of the well and injection facility found no violations.
1500567988 2017-07-12 Salt Water Injection Well No Violations An inspection of the injection well and surface facility found no violations.
1506338303 2017-09-20 Salt Water Injection Well No Violations I was on location to inspect the injection well. The tank battery is in good repair. The proper identification is posted at the facility. There are no violations at this time.
1514558406 2017-12-29 Salt Water Injection Well No Violations I was on location to assess Chiefs Order 2017-274. I found facility and well not in operation on the day of my inspection. The gate at the access road entrance is closed and locked. There is no operator on location. I observed no leaks or spills. I spoke with Bob Barnett from American Energy Associates. Mr. Barnett stated the company does have insurance and will call Columbus ODNR on 1/2/2018 to correct the issue.

American Energy needs to: Immediately cease all injection well operations Submit updated Liability Insurance

1526316696 2018-05-14 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found water with old oil still in the diked tank battery. There are several saturated absorbent pads throughout the dike and pit surrounding the wellhead. Photos were taken and are available upon request. I spoke with Bob Barnett from American Energy. Mr. Barnett stated he is still working on removing the water from the dike. Follow-up inspections will continue.
1528726388 2018-06-11 Salt Water Injection Well No Violations I was on location to assess Compliance Notice # -1415548345. I found no evidence of recent activity. There are still several inches of water with oil residue and numerous saturated absorbent pad in the steel diked tank battery. There are saturated absorbent pads in the pit surrounding the wellhead. The access road gate is closed and locked. An identification sign is posted.

American Energy still needs to: Remove the water and oil residue inside the diked tank battery. Remove and proper dispose of all saturated absorbent pads.

Photos were taken and are available upon request. I left a message with Bob Barnett, owner of American Energy, for a return call concerning the compliance notice.

1533045126 2018-07-31 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found most of the water in the diked tank battery has been pumped down; however, there is still oil and numerous saturated absorbent pads in the dike. Identification signs are posted. The pump house/office is locked and secure. The location is secure with a locked access road gate. Photos were taken and available upon request. I left a voice message with Bob Barnett for a return call concerning the compliance notice.
1545126321 2015-07-14 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
1546522017 2019-01-02 Salt Water Injection Well No Violations I was on location to assess compliance notice # -1415548345. I found the injection was not operating at the time of my inspection. There was a facility operator on location. There were several inches of water throughout the steel diked tank battery. I observed old oil, numerous saturated absorbent pads, and leaf litter floating on the water. There appeared to be an additional oil spill resulting from a possible overflow from two (2) of the 210 bbl storage tanks. I noticed oil residue on the east-northeast sides of the two (2) storage tanks on the north end of the tank battery. All of the water and oil in the tank battery is contained to the dike. Upon further inspection, I found the seven (7) day chart in the meter box between the injection well and tank battery showed American Energy has been operating the injection well at approximately 1,700 psi throughout the week, which is over the allowable maximum pressure of 1,540 psi. Inspection of the Murphy switch shows it is set above the allowable maximum pressure. I questioned the facility operator on location. The facility operator stated:

He had just turned off the injection well when I pulled onto location. The injection well was operating over the allowable maximum pressure. He planned to begin pumping the water in the diked tank battery into the storage tanks. He was not sure if there was an additional spill from the storage tanks.

I told the facility operator:

American Energy is not allowed to operate over pressure. The Murphy switches are to be set no higher than the allowable maximum pressure. All of the water, oil, and saturated absorbent pads need to be cleaned up.

After leaving the site, I received a call from Bob Barnett from American Energy. Mr. Barnett stated:

The facility is receiving only 600 bbl of brine per day. Due to the light water, American Energy is unable to pump fluid down the injection well at the current allowable maximum pressure of 1,540 psi. The formation w

1553019592 2019-03-19 Salt Water Injection Well No Violations I was on location to assess Compliance Notice # -1415548345. I found the injection well not operating during my inspection. All of the saturated absorbent pads have been removed. All of the water in the diked tank battery has been removed. There is still small pool of oil in the southeast corner of the dike. The gravel in the dike is coated with oil. I spoke with Bob Barnett on location. Mr. Barnett stated they are still working on cleaning up the dike and plans to get more done as the weather improves. Follow-up inspection will continue.
1560176221 2019-6-10 0:00: SW No Violations 2.00
1569946305 2019-10-1 0:00: SW No Violations 3.00
1579791385 2020-1-23 0:00: SW No Violations 1.80
1582901815 2020-2-28 0:00: SW No Violations 2.00
1595867969 2020-7-27 0:00: SW No Violations 10.50
1596204243 2020-7-31 0:00: SW No Violations 2.50
1596465128 2020-8-3 0:00:0 SW No Violations
1596638870 2020-8-5 0:00:0 SW No Violations 2.00
1596880465 2015-08-06 Salt Water Injection Well No Violations The well and surface facility were inspected.

One frac tank was removed. The contents of the second tank were sampled. Once the lab results are back, the tank can be cleaned and removed.

1598533003 2016-11-14 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
1628265734 2015-07-29 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
1789724045 2013-05-06 Salt Water Injection Well No Violations A service rig, owned by Chipco, was running in to drill out the last plug.

My inspection found no violations.

1809346343 2017-02-21 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was not operating at the time. There were no violations found.
1815271498 2015-01-15 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1897425764 2015-02-13 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The injection line and annulus were frozen. There were no violations found at the time.
2030842654 2014-03-17 Salt Water Injection Well No Violations Permit to operate has not been granted. There was no sign of recent activity. The site appeared to be secure. No additional problems found.
205032581 2013-2-26 0:00: DD No Violations
2057939702 2014-06-13 Salt Water Injection Well No Violations An inspection of the well and injection facility found no violations.
2098365 2020-6-9 0:00:0 SW No Violations 1.80
2116392528 2014-10-14 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time. According to the well tender, the pressure was bled-off the annulus.
2126128241 2013-05-02 Salt Water Injection Well No Violations A service rig, owned by Chipco, was running in to drill out the plug.

My inspection, accompanied by Tom Hill, found no violations.

215764318 2016-8-30 0:00: SW No Violations
234180965 2018-9-18 0:00: SW No Violations 0.70
332838795 2015-9-4 0:00:0 SW No Violations
381616012 2017-2-9 0:00:0 SW No Violations
382234199 2018-3-19 0:00: SW No Violations 0.80
505303756 2013-2-28 0:00: DD No Violations
553471574 2018-11-15 0:00 SW No Violations 1.10
623078964 2018-7-18 0:00: SW No Violations 1.00
66034713 2017-6-5 0:00:0 SW No Violations
662689640 2014-5-6 0:00:0 SW No Violations
676547517 2015-6-15 0:00: SW No Violations
711028997 2016-12-29 0:00 SW No Violations
732693169 2013-3-11 0:00: DD No Violations
758777040 2016-3-17 0:00: SW No Violations
80502911 2013-3-20 0:00: DD No Violations
816185168 2013-5-10 0:00: SW No Violations
iTOMK00014 2014-02-27 Administrative Inspection No Violations AMERICAN ENERGY INC. SUBMITTED 4TH QUARTER 2013 BRINE DISPOSAL FEES TO THE DIVISION FOR THE JOHNSON DISPOSAL #1 WELL ON FEBRUARY 27, 2014. AUTHORIZATION TO INJECT AT THE JOHNSON DISPOSAL #1 WELL HAD NOT BEEN GRANTED TO AMERICAN ENERGY INC. AS OF THAT DATE, SO THE INJECTION WELL HAS OPERATING WITHOUT AUTHORIZATION TO INJECT BY CHIEFS ORDER FROM THE DIVISION OF OIL AND GAS RESOURCES MANAGEMENT.
iTOMK000144 2014-2-27 0:00: AM No Violations 0.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0555630561 US-OH-126119 2019-04-08 Failure to report disposal fees
0676547517 US-OH-127653 2015-10-15 Exceeding maximum allowable injection pressure
1017598360 US-OH-100511 2018-08-03 NONE Failure to report disposal fees
1415548345 US-OH-112205 2018-03-21 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil
1463677127 US-OH-113431 2016-05-27 Exceeding maximum allowable injection pressure

For data sources see[4]

References