X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-24099

Well Details

Well ID: 34-155-24099
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: HIGHLAND FIELD SERVICES LLC
Well Pad ID:
Farm/Lease Name: HIGHLAND BROOKFIELD (SWIW #37)
License Status: Active Injection
License Date: 2017-06-21
Spud Date: 2018-04-11
Spud Drilling Contractor: FALCON DRLG
Final Drill Date: 2018-06-19
Well Total Depth: 8480.00 ft
Configuration: Vertical
Latitude: 41.240000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-06-21 Proposed Formations:KNOX THRU ROME, Issued Date:6/21/2017, Expired Date:6/19/2018, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW
Reached Total Depth 2018-06-19 AUTHORIZATION TO INJECT GRANTED 10/22/2018
Construction Permit Expires 2018-06-21 AUTHORIZATION TO INJECT GRANTED 10/22/2018
Last Compliance Report 2018-10-24 AUTHORIZATION TO INJECT GRANTED 10/22/2018
Record Last Modified 2018-10-24 AUTHORIZATION TO INJECT GRANTED 10/22/2018

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-10-24 7589 8480 0
7589 8480 0
7589 8480 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1073952577 2018-7-2 0:00:0 DD No Violations 1.30
-1101723191 2018-11-15 0:00 SW No Violations 1.50
-11619439 2018-5-24 0:00: DD No Violations 1.30
-1177351489 2018-7-11 0:00: DD No Violations
-1193747376 2020-3-5 0:00:0 SW No Violations
-1248548378 2018-12-27 0:00 SW No Violations 0.30
-1265404814 2017-11-17 0:00 SW No Violations 1.00
-1314985551 2020-4-20 0:00: SW No Violations 0.60
-1362240278 2018-8-15 0:00: SW No Violations 1.20
-1405551473 2019-2-19 0:00: SW No Violations 0.40
-1419747730 2018-10-30 0:00 SW No Violations 0.50
-1430523634 2018-7-23 0:00: DD No Violations 2.30
-1503624929 2018-2-28 0:00: ND No Violations 0.80
-1591194038 2018-6-11 0:00: DD No Violations 1.50
-1635634908 2019-5-6 0:00:0 SW No Violations 0.50
-1659199742 2018-1-11 0:00: SW No Violations 0.20
-1680391646 2019-6-6 0:00:0 SW No Violations 1.00
-179819436 2018-7-5 0:00:0 DD No Violations 1.50
-1901588304 2019-7-31 0:00: SW No Violations 0.80
-2015423586 2019-2-11 0:00: SW No Violations 0.30
-2116097950 2019-1-7 0:00:0 SW No Violations 1.50
-43642608 2018-6-7 0:00:0 DD No Violations 2.50
-488481407 2018-8-27 0:00: SW No Violations 1.30
-505314882 2019-2-28 0:00: SW No Violations 1.50
-561676346 2018-11-19 0:00 SW No Violations 1.50
-638796763 2018-4-12 0:00: CS No Violations
-678014034 2018-6-13 0:00: DD No Violations 2.80
-841951711 2019-1-10 0:00: SW No Violations 0.40
0011619439 2018-05-24 Drill / Deepen / Reopen No Violations
0043642608 2018-06-07 Drill / Deepen / Reopen No Violations
0110198830 2019-03-04 Salt Water Injection Well No Violations I found the CC Forbes rig has completed milling out the well and was tripping out.
0179819436 2018-07-05 Drill / Deepen / Reopen No Violations I found Keystone Clearwater Solutions still on site working on the secondary containment for frac tanks to be used for testing the well.
0209640194 2018-08-03 Salt Water Injection Well No Violations I found M & B Services on location constructing the forms and rebar in preparation for cementing the Off-Loading pads. GOH was on location performing dirt work for installing the fencing that will surround the well pad.
0287105872 2018-02-16 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) spreading stone on the access road. Four (4) dump trucks full of stone arrived on location during my inspection. There are no violations at this time.
0310235793 2019-01-02 Salt Water Injection Well No Violations I was on location to assess a claim concerning a loud sound/explosion coming from the facility. According to the facility operators, the loud sound/explosion came from a landowner operating firearms south of the facility. Also, facility operators stated the Brookfield Police Department arrived on location between 4:00 pm and 4:30 pm on December 31, 2018 to investigate the loud sound. I found no evidence showing damage resulting from a loud sound/explosion. The facility and injection well are in good repair. I observed no leaks or spills in or around the facility and injection well. The injection well was in operation during my inspection. Glenn O. Hawbaker (GOH) was on location working on the well pads for the Highland #3 and #4. Two (2) Beimel brine trucks (#25-436) and a Rock Run brine truck (#25-665) arrived on location with the proper UIC number, brine, and company information displayed. There are no violations at this time.
0398990959 2018-03-28 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) on site working on the access road and the well pad for the Highland #5.
0399457442 2018-11-08 Salt Water Injection Well No Violations I found the facility operator on location waiting on brine water deliveries. According to the facility operator, the tentative date to start injecting is November 19th.
0473191958 2018-05-18 Drill / Deepen / Reopen No Violations I found Falcon Drilling moving the rig and equipment onto location. There are no violations at this time.
0488481407 2018-08-27 Salt Water Injection Well No Violations I found Seneca Resources/Highland working of the construction of the temporary facility. I reviewed the blueprint for temporary facility and noticed a difference in the layout of the storage tanks. Next, I spoke with Terry Dunmyre from Seneca Resources on location. According to Mr. Dunmyre, the location of the storage tanks and equipment have been rearranged from the blueprint to make laying out the flow lines more efficient. Mr. Dunmyre stated the actual flow direction of the fluid from the off-loading pad to the injection well has not been changed. All of the storage tanks are on location except for a 400 bbl. Also, a crew was on location installing a chain link fence around the entire facility.
0505314882 2019-02-28 Salt Water Injection Well No Violations
0561676346 2018-11-19 Salt Water Injection Well No Violations I found the injection well not in operation on the day of my inspection. Seneca reps were on location for a final walk through of the injection well and temporary facility. I observed no leaks or spills. Identification signs are posted.
0638796763 2018-04-12 Casing String Witnessed No Violations HAD Drilling Rig # 247 was the drilling contractor for Highland Field Services. A 30 casing was concentrically drilled to 37 GL. Bedrock was reported encountered at 10 by HAD Drilling personnel. A 28 borehole was drilled with an air hammer to 83 GL on misted air. A fresh water flow estimated to be approximately 30 gals. / hr. was encountered in this section of the borehole. After the hole was drilled to total depth HAD lowered four joints of 24, 157 lbs. / ft., welded casing open ended into the hole. Circulation windows were cut into the casing 24 from the bottom of the casing. Three (3) bow spring centralizers were welded to the casing at 20, 40 and 60 depths. Petroset Cementing Services (PSC) connected to the casing and circulated 10 barrels of fresh water. The cement mix water was heated to 55 F, pH was 7 and Chlorides were < 250 ppm. The cement load was Class A with a mix yield of 1.18 cu.ft./sk. PCS mixed the cement slurry and displaced it with 38 barrels of water. Cement returns were observed at 30 barrels into displacement. I verified, by scale, cement slurry density at 15.1 ppg and 15.0 ppg. Circulation was observed throughout the entire job. Approximately eight (8) barrels of cement slurry were observed to return to the cellar. Plug was down at 1800 hrs. After twenty minutes , I observed that the cement level had fallen and could not be seen. I request from Gus ( Co-man ) that the cement top be measured after WOC time and topped off even with the 30 drive pipe.
0678014034 2018-06-13 Drill / Deepen / Reopen No Violations I found Falcon Rig 26 running drill pipe into the borehole to resume drilling. There are no violations at this time.
0794753008 2017-11-27 Salt Water Injection Well No Violations
0841951711 2019-01-10 Salt Water Injection Well No Violations I found the injection well in operation. There was a facility operator on location. I observed no leaks or spills. Identification is posted.
0918225664 2018-06-04 Salt Water Injection Well No Violations Falcon Drilling was air drilling at 6123. I inspected the air package, cellar and solids handling areas and did not identify any violations. I spoke with Don Creager ( Co-man) to remind him of the point at which it was required to switch to fluid drilling.
0950224719 2018-08-08 Salt Water Injection Well No Violations I found M & B Services working on the second off-loading concrete pad. Supplies and equipment was being delivered for constructing the temporary facility.
1073952577 2018-07-02 Drill / Deepen / Reopen No Violations I found Keystone Clearwater Solutions on site building a secondary containment for frac tanks to be used for testing the well. Falcon Rig 26 has completely moved off location.
1101723191 2018-11-15 Salt Water Injection Well No Violations I found Seneca reps and the facility manager running final maintenance checks on the electronic controls and pumps. The gate valves on the injection well and injection tubing are open. According to the facility manager, Highland only plans to pump enough fluid today to purge all of the air out of the system (up to 200 bbl.). I observed no spills or leaks within the diked tank battery. Identification signs are posted.
110198830 2019-3-4 0:00:0 SW No Violations 4.50
1118870146 2018-08-13 Salt Water Injection Well No Violations I found M & B Services working on the Off-loading pads. The temporary steel dike is being installed. There are no violations at this time.
1177351489 2018-07-11 Drill / Deepen / Reopen No Violations I was on location to witness the tracer test. Haliburton was contracted to perform the tracer test and Formation Cementers supplied the pump truck.
1248548378 2018-12-27 Salt Water Injection Well No Violations I found the injection well in operation on the day of my inspection. I observed no leaks or spills in or around the injection well and facility. There were two (2) Beimel brine truck on location with the proper UIC number displayed (#25-436). Identification signs are posted. The digital display at the facility read 1407.0 psi for the injection tubing and 152.7 psi for the annulus. There are no violations at this time.
1253402878 2018-12-18 Salt Water Injection Well No Violations I found the injection well in operation on the day of my inspection. Identification signs are posted. There were seven (7) Beimel Transportation brine trucks on location with the proper UIC number, brine, and company information displayed (#25-436). I observed no spills or leaks.
1265404814 2017-11-17 Salt Water Injection Well No Violations
1303810325 2020-7-8 0:00:0 SW No Violations 1.00
1362240278 2018-08-15 Salt Water Injection Well No Violations I found PAC has 13 vac boxes on location resting on the two (2) concrete slabs and off-loading area. PAC is still cleaning the 400 bbl. storage tank. According to the facility operator, one (1) or more of the vac boxes will be removed today.
1405551473 2019-02-19 Salt Water Injection Well No Violations I found SRE placing matting down on the well pad. The injection well is currently shut-in for maintenance.
1419747730 2018-10-30 Salt Water Injection Well No Violations I found injection well shut-
1430523634 2018-07-23 Drill / Deepen / Reopen No Violations
1503624929 2018-02-28 Not Drilled No Violations

-

1512398085 2017-12-04 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time.
1513608889 2017-12-18 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time.
1515079989 2018-01-04 Salt Water Injection Well No Violations
1520538718 2018-03-07 Not Drilled No Violations
1521469083 2018-03-19 Not Drilled No Violations I found Glenn O. Hawbaker (GOH) on site working on the access road and the well pad for the Highland #1. I spoke with Bill Johnson, GOH General Superintendent, and Mike Beers, GOH Site Foreman. Mr. Johnson stated GOH has a projected completion date of April 4, 2018 for the access road and the well pad for the Highland #5.
1523989672 2018-04-17 Salt Water Injection Well No Violations Access to the drilling pad was on a graveled road. HAD Drilling Rig # 247 was demobilized and parked on the pad. The cellar contained water which only allowed approximately three (3) feet of 24 casing visible. I did not see any evidence of gas migration in the cellar. Superior Energy Resources was on location laying down and sealing the containment cloth prior to positioning the rig mats. Subsequent to displacing the cement slurry ( 4/12/2018) the cement level fell down the annular space between the 30 drive pipe and 24 conductor casing and was measured at 28 from the top. Brian Bauer ( Highland Field Services ) said, that the casing was topped off with Sakrete level within the 30 casing stub. The water level in the cellar prevented me from confirming. Mr. Bauer anticipated mobilization of the second HAD Drilling rig around 5/1/2018. No violation identified during this inspection.
1524580283 2018-04-23 Drill / Deepen / Reopen No Violations I found Glenn O. Hawbaker (GOH) on site moving dirt for the UIC facility.
1525270340 2018-05-02 Drill / Deepen / Reopen No Violations I found HAD Drilling staging the rig and equipment onto the well pad. Glenn O. Hawbaker (GOH) is still working on the facility location.
1525701955 2018-05-07 Drill / Deepen / Reopen No Violations I found HAD Drilling rigging down from the well location. I spoke with Justin Green from Seneca. Mr. Green stated the contract between Seneca and HAD Drilling had been terminated. Mr. Green stated Falcon Drilling will be moving onto location around May 21, 2018. The access road is in good repair. Glenn O. Hawbaker (GOH) is still working on pad for the temporary facility. There are no violations at this time.
1527087076 2018-05-23 Drill / Deepen / Reopen No Violations
1529595427 2018-06-21 Drill / Deepen / Reopen No Violations
1531312758 2018-07-10 Drill / Deepen / Reopen No Violations I was on location to witness Highland acid treat the well. Haliburton was contracted to pump the acid. Haliburton pump 1,000 gallons (23.8 bbl.) of 15% acid to the bottom of the well and shut-in with a wellhead pressure reading of 1,297 psi. After 30 minutes, the wellhead pressure dropped to 1,082 psi. Next, Haliburton pumped 165,773 gallons (3,946.9 bbl.) of 10 lb. brine reaching a rate of 50 bbl/min. I observed no leaks or spills from the wellhead.
1531916117 2018-07-17 Drill / Deepen / Reopen No Violations I was on location to witness the setting of the packer and permit a mechanical integrity test (MIT). Excel Site Rental was the contracted rig (#832) and Formation Cementing supplied the pump truck. Halliburton supplied a Versa-Set Retrievable Packer (V--in at 5:00 pm. After 15 minutes, the pressure gauge had a reading of 2,160 psi. I observed no leaks. The MIT passed. Pressure on the annulus was dropped to 600 psi.
1532705967 2018-07-27 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) performing dirt work for the proposed temporary facility and off-loading pad.
1533562489 2018-08-06 Salt Water Injection Well No Violations I found M & B Services pouring concrete for the Off-loading pads. The injection well is in good condition and shut-in while the temporary facility is being constructed.
1534343004 2018-08-15 Salt Water Injection Well No Violations I found M & B Services pouring concrete on the last section for the off-loading pads. The injection well is currently shut-in while the temporary facility is under construction. The well pad and access road are stable and in good repair. I observed Rt. 7 at the entrance of the access road clean and free of all debris.
1536242062 2018-09-05 Salt Water Injection Well No Violations I found Seneca Resources/Highland still working of the construction of the temporary facility. A chain link fence with barb wire has been installed around the facility area and well pad
1539786357 2018-10-09 Salt Water Injection Well No Violations


0 minutes: 1904 psi 5 minutes: 1905 psi 10 minutes: 1906 psi 15 minutes: 1906 psi

There was zero drop in pressure during the test; passed.

1543334384 2018-11-27 Salt Water Injection Well No Violations I found the injection well in operation on the day of my inspection. A facility operator was on location. The digital display read Highland was injecting at 755 psi and the pressure on the annulus was 139 psi. Highland is pumping at a rate of 1.4 BPM. I observed no leaks or spills. While on location, three (3) Beimel Transportation brine trucks arrived on location with the proper UIC number displayed (#25-436). An identification sign is posted on the fencing.
1543932991 2018-12-04 Salt Water Injection Well No Violations I received a call from Marisa Dollinger from Seneca/Highland at 6:29 am concerning a pump failure at the Highland #5 facility with approximately 1 bbl. of brine spilled inside of the containment dike. Ms. Dollinger stated the injection well has been shut-in until repairs are completed. Upon arrival, I found the injection well shut-in. The source of the brine spill was a failed flange gasket from the CoorsTek Stabilizer Cartridge installed on the injection line right after the injection pump located in the diked tank battery. The brine spill was already cleaned up. The brine spill was contained to inside of the dike. I spoke with the facility operator on location. Seneca was in process of obtaining a new gasket. The injection well will remain shut-in until repairs are completed. A follow-up inspection will be conducted.
1544031845 2018-12-05 Salt Water Injection Well No Violations I found Seneca has replaced the gasket on the CoorsTek Stabilizer Cartridge. The injection well was in operation. According to the digital display, the injection well was 1,135 psi and the annulus was 141 psi. There were facility operators on location. I observed no leaks or spills.
1546277883 2018-12-31 Salt Water Injection Well No Violations I was on location due to receiving a call from Marissa Dollinger from Seneca/Highland on 12/28/2018 concerning an issue with the CoorsTek Stabilizer Cartridge on the injection line located inside of the diked tank battery. Ms. Dollinger stated there was a break in the weld; however, there was no brine spill. Upon arrival, I found Seneca/Highland has repaired the CoorsTek Stabilizer Cartridge and installed additional bracing. I observed no evidence to spills or leaks inside of the tank battery. There was a Beimel brine truck off-loading on location with the proper identification on the trailer (#25-436). Two (2) Beimel brine trucks arrived on location with the proper identification.
1551192996 2019-02-25 Salt Water Injection Well No Violations
1551292139 2019-02-27 Salt Water Injection Well No Violations

-in temporarily due to the main hydraulic pump stopped working. CC Forbes will resume tripping into the well once the new hydraulic pump arrives.

1551886086 2019-03-06 Salt Water Injection Well No Violations I found the CC Forbes rigging down and moving equipment off site. The injection well is shut-
1577198086 2019-12-24 0:00 SW No Violations
1578327696 2020-1-6 0:00:0 SW No Violations 2.00
1591194038 2018-06-11 Drill / Deepen / Reopen No Violations
1630450032 2019-03-15 Salt Water Injection Well No Violations I found the injection well shut-in. The injection line is disconnected from the injection well. There are no spills or leaks.
1633928080 2018-09-26 Salt Water Injection Well No Violations I found Seneca Resources/Highland still working of the construction of the temporary facility. The plumbing and electrical were being connected. The chain link fencing around the facility and well has been completed. The injection line from the facility to the injection well has not been ran at this time.
165032842 2019-8-29 0:00: SW No Violations 0.50
1659199742 2018-01-11 Salt Water Injection Well No Violations I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time.
1695693804 2019-01-16 Salt Water Injection Well No Violations I found the injection well not operating during my inspection. I observed no leaks or spills. Identification signs are posted.
1799333988 2019-4-24 0:00: SW No Violations 0.30
1953842728 2018-06-20 Drill / Deepen / Reopen No Violations
2015423586 2019-02-11 Salt Water Injection Well No Violations I found injection well shut-
209640194 2018-8-3 0:00:0 SW No Violations 1.70
2116097950 2019-01-07 Salt Water Injection Well No Violations I found the injection well operating during my inspection. The injection well and facility are in good repair. I observed no leaks or spills. Identification signs are posted. There were two (2) Beimel Transportation brine trucks on location with the proper UIC numbers displayed (#25-436).
287105872 2018-2-16 0:00: SW No Violations 0.30
310235793 2019-1-2 0:00:0 SW No Violations 1.70
329929608 2020-8-24 0:00: SW No Violations 1.00
352637268 2019-10-3 0:00: SW No Violations 0.50
398990959 2018-3-28 0:00: SW No Violations 2.00
399457442 2018-11-8 0:00: SW No Violations 0.80
419609204 2019-7-3 0:00:0 SW No Violations 0.30
435227131 2019-8-20 0:00: SW No Violations 1.00
473191958 2018-5-18 0:00: DD No Violations 2.50
794753008 2017-11-27 0:00 SW No Violations 0.40
918225664 2018-6-4 0:00:0 SW No Violations
950224719 2018-8-8 0:00:0 SW No Violations 0.90

For data sources see[4]

References