Well Details

Well ID: 34-169-22797
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Canaan Township
Operator Name: KENOIL LLC
Well Pad ID:
Farm/Lease Name: IRVIN ARTHUR
License Status: Producing
License Date: 1989-05-10
Spud Date: 1989-08-06
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1989-08-11
Well Total Depth: 3385.00 ft
Configuration: Vertical
Latitude: 40.920000
Longitude: -81.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1981-08-06 RI 5-13-89
Oil and Gas 1982-02-18 Issued Date 8/18/82 Expired Date 8/18/82 Acres 0085000 Tool Type CRA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1989-05-10 627 KENOIL GeoDate 5/10/89
Oil and Gas 1989-05-10 Issued Date 5/10/89 Expired Date 5/10/90 Acres 0085180 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 03385 Proposed Drill Depth 03385
Completed 1989-08-11 RI 5-13-89
Reached Total Depth 1989-08-11 RI 5-13-89
CO 1989-10-13 627 KENOIL GeoDate 2/18/82
Completion Report Received 1989-11-15 RI 5-13-89
Construction Permit Expires 1990-05-10 RI 5-13-89
Record Last Modified 2017-02-15 RI 5-13-89

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3221 3284 0
3221 3284 0
2006-09-11 3225 3229 4
3225 3229 4
3221 3284 0
2006-09-11 3269 3271 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3000 Bbl 40000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 KENOIL LLC 0.00 431.00 365
1990 KENOIL LLC 3208.00 676.00 365
1991 KENOIL LLC 3029.00 393.00 365
1992 KENOIL LLC 2779.00 315.00 365
1993 KENOIL LLC 2491.00 309.00 365
1994 KENOIL LLC 1472.00 152.00 0
1995 KENOIL LLC 785.00 78.00 0
1996 KENOIL LLC 572.00 71.00 0
1997 KENOIL LLC 307.00 0.00 365
1998 KENOIL LLC 1096.00 224.00 365
1999 KENOIL LLC 1968.00 298.00 0
2000 KENOIL LLC 1981.00 210.00 365
2001 KENOIL LLC 1510.00 200.00 365
2002 KENOIL LLC 1864.00 204.00 365
2003 KENOIL LLC 1383.00 206.00 365
2004 KENOIL LLC 1526.00 168.00 365
2005 KENOIL LLC 1379.00 280.00 365
2006 KENOIL LLC 1278.00 204.00 365
2007 KENOIL LLC 1422.00 136.00 365
2008 KENOIL LLC 1767.00 204.00 365
2009 KENOIL LLC 1643.00 133.00 365
2010 KENOIL LLC 1494.00 247.00 365
2011 KENOIL LLC 1176.00 117.00 0
2012 KENOIL LLC 1323.00 193.00 366
2013 KENOIL LLC 1496.00 182.00 365
2014 KENOIL LLC 1296.00 182.00 365
2015 KENOIL LLC 1341.00 206.00 365
2016 KENOIL LLC 1359.00 214.00 365
2017 KENOIL LLC 1337.00 133.00 365
2018 KENOIL LLC 1131.00 172.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 KENOIL LLC Brine 1045 365
1990 KENOIL LLC Brine 80 365
1991 KENOIL LLC Brine 40 365
1992 KENOIL LLC Brine 25 365
1993 KENOIL LLC Brine 25 365
1994 KENOIL LLC Brine 0 0
1995 KENOIL LLC Brine 0 0
1996 KENOIL LLC Brine 0 0
1997 KENOIL LLC Brine 10 365
1998 KENOIL LLC Brine 0 365
1999 KENOIL LLC Brine 0
2000 KENOIL LLC Brine 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 36 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 0 365
2006 KENOIL LLC Brine 0 365
2007 KENOIL LLC Brine 0 365
2008 KENOIL LLC Brine 0 365
2009 KENOIL LLC Brine 0 365
2010 KENOIL LLC Brine 0 365
2011 KENOIL LLC Brine 0
2012 KENOIL LLC Brine 39 366
2013 KENOIL LLC Brine 0 365
2014 KENOIL LLC Brine 0 365
2015 KENOIL LLC Brine 0 365
2016 KENOIL LLC Brine 0 365
2017 KENOIL LLC Brine 0 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1312731464 2018-3-16 0:00: PW No Violations
-1914001864 2017-5-16 0:00: PW No Violations
-1968253771 2020-5-13 0:00: PW No Violations
0000PL1116 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0113539170 2016-03-24 Production Wells No Violations Inspected production well on 03/24/2016. The tank battery consists of 3-100 bbl steel tanks and 2-vertical separators located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
113539170 2016-3-24 0:00: PW No Violations
1312731464 2018-03-16 Production Wells No Violations Inspected production well on 03/16/2018. The tank battery consists of 1-100 bbl steel tank, 1-vertical separator, 1-drip, 1-meter with a drip and regulator, and 1-meter box, located within an earthen dike; the diked area is shared with the tank battery for the Wyckoff Unit #4 well (PN: 169-25345). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1598507738 2016-09-15 Production Wells No Violations Inspected production well on 09/15/2016. The tank battery consists of 3-100 bbl steel tanks and 2-vertical separators, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1914001864 2017-05-16 Production Wells No Violations Inspected production well on 05/16/2017. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator, located within an earthen dike; the diked area is shared with the tank battery for the Wyckoff Unit #4 well (PN: 169-25345). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
PL1116 PL No Violations

For data sources see[9]