If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-23152 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.76,"lon":-82.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Plain Township | |
Operator Name: DERBY OPERATING CORP | |
Well Pad ID: | |
Farm/Lease Name: LADRACH | |
License Status: Producing | |
License Date: 1981-12-17 | |
Spud Date: 1982-03-17 | |
Spud Drilling Contractor: | |
Final Drill Date: 1982-03-21 | |
Well Total Depth: 3148.00 ft | |
Configuration: Vertical | |
Latitude: 40.760000 | |
Longitude: -82.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-12-17 | 2892 DERBY OPERATING CORP GeoDate 12/17/81 |
Original Spud | 1982-03-17 | |
Completed | 1982-03-21 | |
Reached Total Depth | 1982-03-21 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3028 | 3058 | 2 |
3028 | 3058 | 2 | |
3028 | 3058 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 48000 Gal | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DERBY OIL & GAS CORP | 15999.00 | 642.00 | 0 |
1985 | DERBY OIL & GAS CORP | 6294.00 | 210.00 | 309 |
1986 | DERBY OIL & GAS CORP | 3447.00 | 149.00 | 265 |
1988 | DERBY OPERATING CORP | 2515.00 | 76.00 | 365 |
1989 | DERBY OPERATING CORP | 1964.00 | 74.00 | 365 |
1990 | DERBY OPERATING CORP | 1808.00 | 71.00 | 365 |
1991 | DERBY OPERATING CORP | 1172.00 | 0.00 | 365 |
1992 | DERBY OPERATING CORP | 1535.00 | 0.00 | 365 |
1993 | DERBY OPERATING CORP | 1267.00 | 0.00 | 365 |
1994 | DERBY OPERATING CORP | 1181.00 | 77.00 | 365 |
1995 | DERBY OPERATING CORP | 1128.00 | 0.00 | 365 |
1996 | DERBY OPERATING CORP | 833.00 | 73.00 | 365 |
1997 | DERBY OPERATING CORP | 902.00 | 0.00 | 365 |
1998 | DERBY OPERATING CORP | 1182.00 | 78.00 | 365 |
1999 | DERBY OPERATING CORP | 764.00 | 71.00 | 365 |
2000 | DERBY OPERATING CORP | 1210.00 | 68.00 | 365 |
2001 | DERBY OPERATING CORP | 1225.00 | 70.00 | 365 |
2002 | DERBY OPERATING CORP | 1430.00 | 70.00 | 365 |
2003 | DERBY OPERATING CORP | 1137.00 | 55.00 | 365 |
2004 | DERBY OPERATING CORP | 897.00 | 73.00 | 365 |
2005 | DERBY OPERATING CORP | 734.00 | 67.00 | 365 |
2006 | DERBY OPERATING CORP | 670.00 | 0.00 | 365 |
2007 | DERBY OPERATING CORP | 605.00 | 0.00 | 365 |
2008 | DERBY OPERATING CORP | 714.00 | 63.00 | 365 |
2010 | DERBY OPERATING CORP | 708.00 | 0.00 | 365 |
2011 | DERBY OPERATING CORP | 538.00 | 0.00 | 365 |
2012 | DERBY OPERATING CORP | 648.00 | 61.00 | 366 |
2013 | DERBY OPERATING CORP | 708.00 | 65.00 | 365 |
2014 | DERBY OPERATING CORP | 589.00 | 74.00 | 365 |
2015 | DERBY OPERATING CORP | 662.00 | 56.00 | 365 |
2016 | DERBY OPERATING CORP | 728.00 | 71.00 | 365 |
2017 | DERBY OPERATING CORP | 686.00 | 0.00 | 365 |
2018 | DERBY OPERATING CORP | 876.00 | 73.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DERBY OIL & GAS CORP | Brine | 138 | 0 |
1985 | DERBY OIL & GAS CORP | Brine | 87 | 309 |
1986 | DERBY OIL & GAS CORP | Brine | 24 | 265 |
1988 | DERBY OPERATING CORP | Brine | 20 | 365 |
1989 | DERBY OPERATING CORP | Brine | 21 | 365 |
1990 | DERBY OPERATING CORP | Brine | 13 | 365 |
1991 | DERBY OPERATING CORP | Brine | 13 | 365 |
1992 | DERBY OPERATING CORP | Brine | 13 | 365 |
1993 | DERBY OPERATING CORP | Brine | 14 | 365 |
1994 | DERBY OPERATING CORP | Brine | 11 | 365 |
1995 | DERBY OPERATING CORP | Brine | 0 | 365 |
1996 | DERBY OPERATING CORP | Brine | 3 | 365 |
1997 | DERBY OPERATING CORP | Brine | 16 | 365 |
1998 | DERBY OPERATING CORP | Brine | 0 | 365 |
1999 | DERBY OPERATING CORP | Brine | 0 | 365 |
2000 | DERBY OPERATING CORP | Brine | 0 | 365 |
2001 | DERBY OPERATING CORP | Brine | 0 | 365 |
2002 | DERBY OPERATING CORP | Brine | 0 | 365 |
2003 | DERBY OPERATING CORP | Brine | 0 | 365 |
2004 | DERBY OPERATING CORP | Brine | 0 | 365 |
2005 | DERBY OPERATING CORP | Brine | 0 | 365 |
2006 | DERBY OPERATING CORP | Brine | 0 | 365 |
2007 | DERBY OPERATING CORP | Brine | 25 | 365 |
2008 | DERBY OPERATING CORP | Brine | 0 | 365 |
2010 | DERBY OPERATING CORP | Brine | 0 | 365 |
2011 | DERBY OPERATING CORP | Brine | 0 | 365 |
2012 | DERBY OPERATING CORP | Brine | 0 | 366 |
2013 | DERBY OPERATING CORP | Brine | 0 | 365 |
2014 | DERBY OPERATING CORP | Brine | 0 | 365 |
2015 | DERBY OPERATING CORP | Brine | 0 | 365 |
2016 | DERBY OPERATING CORP | Brine | 0 | 365 |
2017 | DERBY OPERATING CORP | Brine | 0 | 365 |
2018 | DERBY OPERATING CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-127638818 | 2014-7-3 0:00:0 | PW | No Violations | 0.50 |
-6347754 | 2015-7-20 0:00: | PW | No Violations | 0.50 |
-716180911 | 2017-8-21 0:00: | PW | No Violations | |
-737663361 | 2018-10-30 0:00 | PW | No Violations | |
0006347754 | 2015-07-20 | Production Wells | No Violations | This is a pump jack well. No apparent problems nor compliance issues at this time. |
0127638818 | 2014-07-03 | Production Wells | No Violations | Pumping unit well with no apparent problems at time of inspection. |
0716180911 | 2017-08-21 | Production Wells | No Violations | Inspected production well on 08/21/2017. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, and a drip, regulator, and meter. No problems were noted at the time of the inspection. |
0737663361 | 2018-10-30 | Production Wells | No Violations | Inspected production well on 10/30/2018. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, and 1-meter with an enclosed drip and regulator. No problems were noted at the time of the inspection. |
1049189234 | 2020-5-11 0:00: | PW | No Violations | |
1154326106 | 2016-10-06 | Production Wells | No Violations | Inspected production well on 10/06/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |
1339463728 | 2013-02-07 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
1810318413 | 2016-03-16 | Production Wells | No Violations | Inspected production well on 03/16/2016. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection. |