X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-23559

Well Details

Well ID: 34-169-23559
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Milton Township
Operator Name: D & D ENERGY COMPANY
Well Pad ID:
Farm/Lease Name: LENGACHER ROBERT & WAMDA
License Status: Producing
License Date: 1983-05-17
Spud Date: 1983-08-26
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1983-10-13
Well Total Depth: 3587.00 ft
Configuration: Vertical
Latitude: 40.970000
Longitude: -81.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-05-17 265 CSAPO FRANK A JR GeoDate 5/17/83
Oil and Gas 1983-05-17 Issued Date 5/17/83 Expired Date 11/13/83 Acres 0114360 Tool Type CT Proposed Formation CLINTON Proposed Depth 03587 Proposed Drill Depth 03587
Original Spud 1983-08-26
Completed 1983-10-13
Reached Total Depth 1983-10-13
Construction Permit Expires 1983-11-13
Completion Report Received 1985-01-11
Change of Owner 2013-01-07 Operator changed from 265, CSAPO LIMITED to 8423, C & C PRODUCING LLC
Change of Owner 2016-11-14 Operator changed from 8423, C & C PRODUCING LLC to 5569, D & D ENERGY COMPANY
Record Last Modified 2016-11-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 0 0
0 0
2006-09-11 3450 3510 32
3450 3510 32
0 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 30000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 CSAPO LIMITED 4177.00 1159.00 0
1985 CSAPO LIMITED 3810.00 500.00 365
1986 CSAPO LIMITED 0.00 0.00 365
1987 CSAPO LIMITED 1090.00 180.00 365
1988 CSAPO LIMITED 706.00 158.00 365
1989 CSAPO LIMITED 0.00 0.00 365
1990 CSAPO LIMITED 0.00 0.00 0
1991 CSAPO LIMITED 0.00 0.00 365
1992 CSAPO LIMITED 0.00 0.00 0
1993 CSAPO LIMITED 0.00 0.00 0
1994 CSAPO LIMITED 1491.00 39.00 365
1995 CSAPO LIMITED 387.00 36.00 365
1996 CSAPO LIMITED 1297.00 36.00 365
1997 CSAPO LIMITED 900.00 49.00 365
1998 CSAPO LIMITED 374.00 0.00 365
2000 CSAPO LIMITED 137.00 36.00 365
2001 CSAPO LIMITED 230.00 0.00 365
2002 CSAPO LIMITED 181.00 36.00 365
2003 CSAPO LIMITED 185.00 0.00 365
2004 CSAPO LIMITED 148.00 38.00 365
2005 CSAPO LIMITED 66.00 0.00 365
2006 CSAPO LIMITED 54.00 35.00 365
2007 CSAPO LIMITED 84.00 35.00 365
2008 CSAPO LIMITED 140.00 0.00 365
2009 CSAPO LIMITED 63.00 36.00 365
2010 CSAPO LIMITED 0.00 23.00 365
2012 CSAPO LIMITED 0.00 43.00 366
2013 C & C PRODUCING LLC 0.00 15.00 365
2014 C & C PRODUCING LLC 0.00 14.00 365
2015 C & C PRODUCING LLC 0.00 0.00 0
2016 D & D ENERGY COMPANY 0.00 0.00 0
2017 D & D ENERGY COMPANY 0.00 0.00 0
2018 D & D ENERGY COMPANY 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 CSAPO LIMITED Brine 0 0
1985 CSAPO LIMITED Brine 52 365
1986 CSAPO LIMITED Brine 0 365
1987 CSAPO LIMITED Brine 71 365
1988 CSAPO LIMITED Brine 22 365
1989 CSAPO LIMITED Brine 0 365
1990 CSAPO LIMITED Brine 0 0
1991 CSAPO LIMITED Brine 0 365
1992 CSAPO LIMITED Brine 0 0
1993 CSAPO LIMITED Brine 0 0
1994 CSAPO LIMITED Brine 12 365
1995 CSAPO LIMITED Brine 0 365
1996 CSAPO LIMITED Brine 0 365
1997 CSAPO LIMITED Brine 0 365
1998 CSAPO LIMITED Brine 20 365
2000 CSAPO LIMITED Brine 15 365
2001 CSAPO LIMITED Brine 0 365
2002 CSAPO LIMITED Brine 20 365
2003 CSAPO LIMITED Brine 0 365
2004 CSAPO LIMITED Brine 0 365
2005 CSAPO LIMITED Brine 17 365
2006 CSAPO LIMITED Brine 22 365
2007 CSAPO LIMITED Brine 28 365
2008 CSAPO LIMITED Brine 9 365
2009 CSAPO LIMITED Brine 19 365
2010 CSAPO LIMITED Brine 14 365
2012 CSAPO LIMITED Brine 17 366
2013 C & C PRODUCING LLC Brine 9 365
2014 C & C PRODUCING LLC Brine 14 365
2015 C & C PRODUCING LLC Brine 13 0
2016 D & D ENERGY COMPANY Brine 0 0
2017 D & D ENERGY COMPANY Brine 0 0
2018 D & D ENERGY COMPANY Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1004192347 2015-5-22 0:00: PW No Violations 0.50
-1633535817 2020-6-17 0:00: PW No Violations
-1813999646 2013-5-24 0:00: PW No Violations 0.50
-2091883617 2018-8-7 0:00:0 PW No Violations
00000PL858 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1004192347 2015-05-22 Production Wells No Violations This is a pumping unit well. There are no evident issues at time of inspection.
1069882090 2016-09-08 Production Wells No Violations Inspected production well on 09/08/2016. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1552937544 2014-05-07 Production Wells No Violations This is a pumping unit well. There are no apparent problems at this time.
1697701247 2017-06-14 Production Wells No Violations Inspected production well on 06/14/2017. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1813999646 2013-05-24 Production Wells No Violations This is a pump jack well. There are no apparent problems at this time.
2091883617 2018-08-07 Production Wells No Violations Inspected production well on 08/07/2018. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
PL858 PL No Violations

For data sources see[9]

References