X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-23790

Well Details

Well ID: 34-169-23790
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Chester Township
Operator Name: CUTTER OIL LLC
Well Pad ID:
Farm/Lease Name: GEORGE
License Status: Producing
License Date: 1985-05-29
Spud Date: 1985-09-19
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1985-09-22
Well Total Depth: 3302.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-03-30 442 ORION ENERGY CORP GeoDate 3/30/84
Oil and Gas 1984-03-30 Issued Date 3/30/84 Expired Date 9/26/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1985-05-29 2050 ORION PETRO CORP GeoDate 5/29/85
Oil and Gas 1985-05-29 Issued Date 5/29/85 Expired Date 5/29/86 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03302 Proposed Drill Depth 03302
Original Spud 1985-09-19 R.I. 6-1-85 IP.AF. S/WATER
Completed 1985-09-22 R.I. 6-1-85 IP.AF. S/WATER
Reached Total Depth 1985-09-22 R.I. 6-1-85 IP.AF. S/WATER
Completion Report Received 1985-11-20 R.I. 6-1-85 IP.AF. S/WATER
Construction Permit Expires 1986-05-29 R.I. 6-1-85 IP.AF. S/WATER
CO 1995-02-13 169 SMAIL JAMES R GeoDate 5/29/85
Change of Owner 2012-10-29 Operator changed from 169, SMAIL JAMES R INC to 8837, HARD ROCK DRILLING & PROD LLC
Change of Owner 2013-09-03 Operator changed from 8837, HARD ROCK DRILLING & PROD LLC to 9178, CUTTER OIL LLC
Record Last Modified 2017-02-15 R.I. 6-1-85 IP.AF. S/WATER

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3226 3240 29
3226 3240 29
3226 3240 29

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 44000 Gal 20000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 ORION PETRO CORP 128.00 524.00 42
1986 ORION PETRO CORP 10218.00 1353.00 333
1987 ORION PETRO CORP 4969.00 685.00 365
1988 ORION PETRO CORP 4153.00 455.00 365
1989 ORION PETRO CORP 4.00 291.00 365
1990 ORION PETRO CORP 2573.00 273.00 365
1991 ORION PETRO CORP 2022.00 124.00 365
1992 ORION PETRO CORP 1704.00 173.00 365
1993 ORION PETRO CORP 1251.00 79.00 365
1994 ORION PETRO CORP 472.00 86.00 212
1995 JAMES R SMAIL INC 449.00 77.00 210
1996 JAMES R SMAIL INC 277.00 46.00 365
1997 JAMES R SMAIL INC 1075.00 82.00 365
1998 JAMES R SMAIL INC 868.00 0.00 365
1999 JAMES R SMAIL INC 907.00 77.00 365
2000 JAMES R SMAIL INC 1025.00 93.00 365
2001 JAMES R SMAIL INC 1274.00 0.00 365
2002 JAMES R SMAIL INC 505.00 74.00 365
2003 JAMES R SMAIL INC 457.00 47.00 365
2004 JAMES R SMAIL INC 469.00 49.00 365
2005 JAMES R SMAIL INC 383.00 39.00 365
2006 JAMES R SMAIL INC 149.00 0.00 365
2007 JAMES R SMAIL INC 347.00 75.00 365
2008 JAMES R SMAIL INC 336.00 0.00 365
2009 JAMES R SMAIL INC 322.00 78.00 365
2010 JAMES R SMAIL INC 364.00 0.00 365
2011 JAMES R SMAIL INC 304.00 0.00 365
2012 JAMES R SMAIL INC 334.00 70.00 366
2013 CUTTER OIL COMPANY 241.00 15.00 365
2014 CUTTER OIL LLC 331.00 0.00 365
2015 CUTTER OIL LLC 239.00 0.00 365
2016 CUTTER OIL LLC 145.00 0.00 365
2017 CUTTER OIL LLC 12.00 0.00 365
2018 CUTTER OIL LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 ORION PETRO CORP Brine 91 42
1986 ORION PETRO CORP Brine 21 333
1987 ORION PETRO CORP Brine 3 365
1988 ORION PETRO CORP Brine 9 365
1989 ORION PETRO CORP Brine 7 365
1990 ORION PETRO CORP Brine 7 365
1991 ORION PETRO CORP Brine 15 365
1992 ORION PETRO CORP Brine 0 365
1993 ORION PETRO CORP Brine 0 365
1994 ORION PETRO CORP Brine 0 212
1995 JAMES R SMAIL INC Brine 0 210
1996 JAMES R SMAIL INC Brine 0 365
1997 JAMES R SMAIL INC Brine 0 365
1998 JAMES R SMAIL INC Brine 0 365
1999 JAMES R SMAIL INC Brine 365
2000 JAMES R SMAIL INC Brine 365
2001 JAMES R SMAIL INC Brine 365
2002 JAMES R SMAIL INC Brine 0 365
2003 JAMES R SMAIL INC Brine 0 365
2004 JAMES R SMAIL INC Brine 8 365
2005 JAMES R SMAIL INC Brine 0 365
2006 JAMES R SMAIL INC Brine 0 365
2007 JAMES R SMAIL INC Brine 0 365
2008 JAMES R SMAIL INC Brine 0 365
2009 JAMES R SMAIL INC Brine 30 365
2010 JAMES R SMAIL INC Brine 0 365
2011 JAMES R SMAIL INC Brine 0 365
2012 JAMES R SMAIL INC Brine 0 366
2013 CUTTER OIL COMPANY Brine 0 365
2014 CUTTER OIL LLC Brine 0 365
2015 CUTTER OIL LLC Brine 0 365
2016 CUTTER OIL LLC Brine 0 365
2017 CUTTER OIL LLC Brine 0 365
2018 CUTTER OIL LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1151816066 2013-4-18 0:00: PW No Violations 0.50
-1539033787 2016-8-18 0:00: PW No Violations
-1676909494 2016-3-2 0:00:0 PW No Violations
-814585876 2018-3-16 0:00: PW No Violations
-923787550 2014-7-11 0:00: PW No Violations 0.50
00000PL706 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0814585876 2018-03-16 Production Wells No Violations Inspected production well on 03/16/2018. The tank battery consists of 1-100 bbl steel tank, 1-1,300 gal plastic tank (shared), 1-vertical separator, 1-drip (shared), and 1-meter box (shared), located within an earthen dike; the diked area and noted equipment is shared with the George #5 well (PN: 169-23789). Additionally, 1-drip and 1-meter box labelled as belonging to the Peacock #4 well also shares the diked area. The well is equipped with a pump jack with a natural gas-powered motor and 1-10 bbl steel tank. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0923787550 2014-07-11 Production Wells No Violations This pumping unit well has no apparent problems at time of inspection.
1151816066 2013-04-18 Production Wells No Violations This is a producing pumping unit. There appears to be no problems at time of inspection.
1204211280 2017-03-22 Production Wells No Violations Inspected production well on 03/22/2017. The tank battery consists of 1-100 bbl steel tank, 1-1,300 gal plastic tank (shared), and 1-vertical separator, located within an earthen dike; the diked area is shared with the George #5 tank battery (PN: 169-23789). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a natural gas-powered motor, and 1-25 bbl steel tank. No dike is present around the steel tank at the wellhead. CJ Cutter with Cutter Oil was notified of this issue and will address it as promptly as weather permits. No other problems were noted at the time of the inspection.
1539033787 2016-08-18 Production Wells No Violations Inspected production well on 08/18/2016. The tank battery consists of 1-100 bbl stee ltank and 1-vertical separator, located within an earthen dike. The diked area is shared with the tank battery for the George #5 well (PN: 169-23789). Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with a natural gas-powered motor. No problems were noted at the time of the inspection.
1676909494 2016-03-02 Production Wells No Violations Inspected production well on 03/02/2016. The tank battery consists of 2-100 bbl steel tanks, 1-1,300 gal plastic tank, and 2-vertical separators located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with a gas-powered motor, and 1-25 bbl steel tank. No dike is present around the tank, nor is well identification posted at the wellhead as required. CJ Cutter with Cutter Oil was notified of these issues and will have them addressed promptly. No other problems were noted at the time of the inspection.
2058901117 2015-07-09 Production Wells No Violations This pumping unit well has no apparent problems nor compliance issues at this time.
2131455391 2020-8-12 0:00: PW No Violations
PL706 PL No Violations

For data sources see[9]

References