34-169-24596

Well Details

Well ID: 34-169-24596
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Clinton Township
Operator Name: CAPSTONE OIL PRODUCING LLC
Well Pad ID:
Farm/Lease Name: TROUTMAN WILLIAM
License Status: Producing
License Date: 1988-02-17
Spud Date: 1988-05-04
Spud Drilling Contractor: KIDD DRILLING
Final Drill Date: 1988-05-31
Well Total Depth: 3179.00 ft
Configuration: Vertical
Latitude: 40.720000
Longitude: -82.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-02-17 Issued Date 2/17/88 Expired Date 2/16/89 Acres 0045390 Tool Type CT Proposed Formation CLINTON Proposed Depth 03179 Proposed Drill Depth 03179
Original Spud 1988-05-04 CHG. ACG. 7-23-88
Completed 1988-05-31 CHG. ACG. 7-23-88
Reached Total Depth 1988-05-31 CHG. ACG. 7-23-88
CO 1988-07-22 627 KENOIL GeoDate 2/17/88
Completion Report Received 1988-08-11 CHG. ACG. 7-23-88
Construction Permit Expires 1989-02-16 CHG. ACG. 7-23-88
Change of Owner 2018-12-18 Operator changed from 627, KENOIL LLC to 9349, CAPSTONE OIL PRODUCING LLC
Record Last Modified 2018-12-18 CHG. ACG. 7-23-88

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3070 3172 0
3070 3172 0
2006-09-11 3145 3154 8
3145 3154 8
3070 3172 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 35000 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 KENOIL LLC 8487.00 3043.00 365
1989 KENOIL LLC 28922.00 3665.00 365
1990 KENOIL LLC 8819.00 1450.00 365
1991 KENOIL LLC 10469.00 1420.00 365
1992 KENOIL LLC 6929.00 767.00 365
1993 KENOIL LLC 4685.00 544.00 365
1994 KENOIL LLC 4515.00 396.00 0
1995 KENOIL LLC 3465.00 236.00 0
1996 KENOIL LLC 2311.00 388.00 0
1997 KENOIL LLC 1702.00 148.00 365
1998 KENOIL LLC 1579.00 287.00 365
1999 KENOIL LLC 1401.00 132.00 0
2000 KENOIL LLC 1005.00 140.00 365
2001 KENOIL LLC 843.00 145.00 365
2002 KENOIL LLC 781.00 141.00 365
2003 KENOIL LLC 912.00 131.00 365
2004 KENOIL LLC 822.00 68.00 365
2005 KENOIL LLC 557.00 199.00 365
2006 KENOIL LLC 672.00 56.00 365
2007 KENOIL LLC 591.00 74.00 365
2008 KENOIL LLC 445.00 124.00 365
2009 KENOIL LLC 700.00 126.00 365
2010 KENOIL LLC 655.00 55.00 365
2011 KENOIL LLC 328.00 56.00 0
2012 KENOIL LLC 494.00 0.00 366
2013 KENOIL LLC 344.00 74.00 365
2014 KENOIL LLC 598.00 106.00 365
2015 KENOIL LLC 495.00 51.00 365
2016 KENOIL LLC 398.00 41.00 365
2017 KENOIL LLC 455.00 66.00 365
2018 KENOIL LLC 198.00 25.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 KENOIL LLC Brine 1053 365
1989 KENOIL LLC Brine 165 365
1990 KENOIL LLC Brine 120 365
1991 KENOIL LLC Brine 155 365
1992 KENOIL LLC Brine 86 365
1993 KENOIL LLC Brine 105 365
1994 KENOIL LLC Brine 28 0
1995 KENOIL LLC Brine 60 0
1996 KENOIL LLC Brine 0 0
1997 KENOIL LLC Brine 30 365
1998 KENOIL LLC Brine 60 365
1999 KENOIL LLC Brine 15
2000 KENOIL LLC Brine 115 365
2001 KENOIL LLC Brine 75 365
2002 KENOIL LLC Brine 20 365
2003 KENOIL LLC Brine 60 365
2004 KENOIL LLC Brine 62 365
2005 KENOIL LLC Brine 0 365
2006 KENOIL LLC Brine 75 365
2007 KENOIL LLC Brine 30 365
2008 KENOIL LLC Brine 22 365
2009 KENOIL LLC Brine 110 365
2010 KENOIL LLC Brine 45 365
2011 KENOIL LLC Brine 64
2012 KENOIL LLC Brine 5 366
2013 KENOIL LLC Brine 69 365
2014 KENOIL LLC Brine 37 365
2015 KENOIL LLC Brine 30 365
2016 KENOIL LLC Brine 37 365
2017 KENOIL LLC Brine 8 365
2018 KENOIL LLC Brine 63 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1740406795 2015-7-9 0:00:0 PW No Violations 0.50
-1904280020 2017-6-30 0:00: PW No Violations
-565882479 2016-9-27 0:00: PW No Violations
00000PL180 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0565882479 2016-09-27 Production Wells No Violations Inspected production well on 09/27/2016. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, and 1-vertical separator, located within an earthen dike; 1-methanol tank and 1-compressor are located nearvy. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1404217836 2014-07-01 Production Wells No Violations This pumping unit well has no apparent problems at time of inspection. Tank battery is equipped with a small compressor in operation at time of inspection.
1740406795 2015-07-09 Production Wells No Violations This is a pumping unit well. There are no evident problems nor compliance issues at this time.
1765070034 2016-03-14 Production Wells No Violations Inspected production well on 03/14/2016. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, and 1-vertical separator located within an earthen dike. 1-compressor is located nearby; a small gas leak was noted at the compressor. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The area around the wellhead needs cleaned-up. Martha Morris with Kenoil was notified of these issues and will have them addressed promptly. No other problems were noted at the time of the inspection.
1904280020 2017-06-30 Production Wells No Violations Inspected production well on 06/30/2017. The tank battery consists of 1-100 bbl steel tank, 1-1,600 gal plastic tank, 1-vertical separator, 2-drips, 1-meter, and 1-meter box, located within an earthen dike; 1-compressor is located nearby. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
2092362306 2020-5-8 0:00:0 PW No Violations
PL180 PL No Violations

For data sources see[9]

References