34-169-24669

Well Details

Well ID: 34-169-24669
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Salt Creek Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: MILLER ELLA
License Status: Producing
License Date: 1988-12-12
Spud Date: 1989-02-07
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1989-02-09
Well Total Depth: 3967.00 ft
Configuration: Vertical
Latitude: 40.700000
Longitude: -81.820000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-12-12 Issued Date 12/12/88 Expired Date 12/12/89 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03967 Proposed Drill Depth 03967
Original Spud 1989-02-06
Completed 1989-02-09
Reached Total Depth 1989-02-09
CO 1989-06-01 139 MB OPERATING CO INC GeoDate 12/12/88
Completion Report Received 1989-06-28
Construction Permit Expires 1989-12-12
Change of Owner 2000-06-30 Operator changed from 139, MB OPERATING CO INC to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2010-04-08 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC
Change of Owner 2017-05-01 Operator changed from 7578, ENERVEST OPERATING LLC, to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-05-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3857 3914 0
3857 3914 0
2006-09-11 3862 3925 24
3862 3925 24
3857 3914 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3781 Bbl 0 SLICKWATER FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 MB OPERATING CO INC 11777.00 0.00 365
1990 MB OPERATING CO INC 20519.00 0.00 365
1992 MB OPERATING CO INC 10516.00 0.00 366
1993 MB OPERATING CO INC 8910.00 0.00 365
1994 MB OPERATING CO INC 8271.00 0.00 365
1995 MB OPERATING CO INC 7824.00 0.00 365
1996 MB OPERATING CO INC 6726.00 0.00 366
1997 MB OPERATING CO INC 5823.00 0.00 365
1999 MB OPERATING CO INC 2973.00 0.00 273
2000 RANGE RESOURCES-APPALACHIA LLC 3718.00 0.00 365
2001 RANGE RESOURCES-APPALACHIA LLC 3896.00 0.00 365
2002 RANGE RESOURCES-APPALACHIA LLC 3626.00 0.00 365
2003 RANGE RESOURCES-APPALACHIA LLC 3571.00 0.00 365
2004 RANGE RESOURCES-APPALACHIA LLC 3421.00 0.00 365
2005 RANGE RESOURCES-APPALACHIA LLC 3226.00 0.00 365
2006 RANGE RESOURCES-APPALACHIA LLC 3263.00 0.00 365
2007 RANGE RESOURCES-APPALACHIA LLC 3176.00 0.00 365
2008 RANGE RESOURCES-APPALACHIA LLC 2706.00 0.00 365
2009 RANGE RESOURCES-APPALACHIA LLC 1439.00 0.00 365
2010 ENERVEST OPERATING LLC 1770.00 0.00 365
2011 ENERVEST OPERATING LLC 2686.00 0.00 0
2012 ENERVEST OPERATING LLC 2765.00 0.00 366
2013 ENERVEST OPERATING LLC 1994.00 0.00 365
2014 ENERVEST OPERATING LLC 1609.00 0.00 365
2015 ENERVEST OPERATING LLC 1428.00 0.00 365
2016 ENERVEST OPERATING LLC 1064.00 33.00 366
2017 ENERVEST OPERATING LLC 386.00 0.00 181
2018 M & R INVESTMENTS OHIO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 MB OPERATING CO INC Brine 55 365
1990 MB OPERATING CO INC Brine 70 365
1992 MB OPERATING CO INC Brine 0 366
1993 MB OPERATING CO INC Brine 0 365
1994 MB OPERATING CO INC Brine 70 365
1995 MB OPERATING CO INC Brine 0 365
1996 MB OPERATING CO INC Brine 0 366
1997 MB OPERATING CO INC Brine 0 365
1999 MB OPERATING CO INC Brine 0 273
2000 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2001 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2002 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2003 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2004 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2005 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2006 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2008 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2009 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 60 365
2011 ENERVEST OPERATING LLC Brine 0
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 42 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 31 366
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1568285546 2017-6-7 0:00:0 PW No Violations
00000PL121 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1452485495 2015-03-18 Production Wells No Violations This pumping unit well has no apparent issues at this time.
1568285546 2017-06-07 Production Wells No Violations Inspected production well on 06/07/2017. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, 2-drips, 1-meter, and 1-meter box, located within an earthen dike. The 50 bbl steel tank was noted to be rusted through in spots, but did not appear to be in-use at the time of the inspection. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
2110001326 2014-02-12 Production Wells No Violations This is a producing pumping unit well. No apparent problems at time of inspection.
2138805107 2016-07-26 Production Wells No Violations Inspected production well on 07/26/2016. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, and 1-drip, located within an earthen dike. The 50 bbl tank is rusted through in spots, and needs emptied and removed. Tim McConaha, Enervests Field Superintendent, was notified of this issue and will have it addressed promptly. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No other problems were noted at the time of the inspection.
PL121 PL No Violations

For data sources see[9]