If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25029 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.9,"lon":-81.92,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wayne Township | |
Operator Name: PETRO EVALUATION SERVICES INC | |
Well Pad ID: | |
Farm/Lease Name: JAQUET UNIT | |
License Status: Producing | |
License Date: 1995-03-15 | |
Spud Date: 1995-03-31 | |
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]] | |
Final Drill Date: 1995-04-07 | |
Well Total Depth: 5676.00 ft | |
Configuration: Vertical | |
Latitude: 40.900000 | |
Longitude: -81.920000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1995-03-15 | Issued Date 3/15/95 Expired Date 3/14/96 Acres 0050130 Tool Type RTAF Proposed Formation TREMPEALEAU Proposed Depth 05676 Proposed Drill Depth 05676 |
Original Spud | 1995-04-01 | |
Completed | 1995-04-07 | |
Reached Total Depth | 1995-04-07 | |
CO | 1995-07-01 | 164 PETRO EVALUATION SERV INC GeoDate 3/15/95 |
Completion Report Received | 1995-12-18 | |
Construction Permit Expires | 1996-03-14 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5596 | 0 | |
5596 | 0 | ||
5596 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 2000 Gal | 0 | ACIDIZED W/2000 GAL 15% HCL |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1411698404 | 2015-12-9 0:00: | PW | No Violations | |
-1675489434 | 2019-9-26 0:00: | PW | No Violations | |
-1996498428 | 2017-3-20 0:00: | PW | No Violations | |
-442422993 | 2017-3-13 0:00: | PW | No Violations | |
-921405628 | 2017-3-13 0:00: | PL | No Violations | |
0000017649 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 7/24/95 INSPECTOR MARK MORELAND DATE 07/2419/95 DATA FROM OLD VAX INFO | |
0442422993 | 2017-03-13 | Production Wells | No Violations | Inspected production well on 03/13/2017. The tank battery consists of 1-210 bbl steel tank, 1-100 bbl steel tank, and 1-vertical separator - no earthen dike is present. A small fluid leak was noted at the separator, which will need to be repaired and cleaned-up. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. The well was noted to have blown a valve off, and was leaking gas and fluids. Petro Evaluations office was notified of these issues and dispatched Steve Franks to the location. These issues were discussed on-site with Mr. Franks, and will be addressed by the end of the week. Will follow-up to ensure issues have been addressed. No other problems were noted at the time of the inspection. |
0921405628 | 2017-03-13 | Preliminary Restoration | No Violations | Inspected production well on 03/13/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1411698404 | 2015-12-09 | Production Wells | No Violations | Inspected production well on 12/09/2015. The tank battery consists of 1-210 bbl steel tank, 1-100 bbl steel tank, and 1-vertical separator located within a shallow earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection. |
17649 | PL | No Violations | ||
1996498428 | 2017-03-20 | Production Wells | No Violations | Visited location on 03/20/2017 to follow-up on clean-up operations at both the tank battery and the wellhead. All oil has been removed from the tank battery, fresh stone laid where needed, and an earthen dike constructed. All affected soil has been removed from the wellhead area and fresh stone laid. All clean-up has been completed, and no further issues were noted at the time of the inspection. |
935191866 | 2020-5-26 0:00: | PW | No Violations |
For data sources see[9]