Well ID: 34-169-25051 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.91,"lon":-81.94,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Canaan Township | |
Operator Name: PETRO EVALUATION SERVICES INC | |
Well Pad ID: | |
Farm/Lease Name: BEYELER LOWELL | |
License Status: Producing | |
License Date: 1995-07-03 | |
Spud Date: 1995-08-10 | |
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]] | |
Final Drill Date: 1995-08-16 | |
Well Total Depth: 5615.00 ft | |
Configuration: Vertical | |
Latitude: 40.910000 | |
Longitude: -81.940000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1995-07-03 | Issued Date 7/3/95 Expired Date 7/2/96 Acres 0045126 Tool Type RTAF Proposed Formation CLINTON/TPLU Proposed Depth 05615 Proposed Drill Depth 05615 |
Original Spud | 1995-08-11 | |
Completed | 1995-08-16 | |
Reached Total Depth | 1995-08-16 | |
CO | 1995-11-01 | 164 PETRO EVALUATION SERV INC GeoDate 7/3/95 |
Construction Permit Expires | 1996-07-02 | |
Completion Report Received | 1996-07-31 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5537 | 0 | |
5537 | 0 | ||
2006-09-11 | 5551 | 5555 | 33 |
5551 | 5555 | 33 | |
5537 | 0 | ||
2006-09-11 | 5585 | 5590 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 2000 Gal | 0 | TREATED W/2000 GAL HCL ACID |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1173348181 | 2015-12-9 0:00: | PW | No Violations | |
-943612900 | 2016-9-14 0:00: | PW | No Violations | |
0000014960 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 12/15/95 INSPECTOR MARK MORELAND DATE 12/1519/95 DATA FROM OLD VAX INFO | |
0943612900 | 2016-09-14 | Production Wells | No Violations | Inspected production well on 09/14/2016. The tank battery consists of 2-100 bbl steel tanks and 1-horizontal separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection. |
1049755770 | 2017-02-02 | Production Wells | No Violations | Inspected production well on 02/02/2017. The tank battery consists of 2-100 bbl steel tanks and 1-horizontal separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. A small stuffing box leak was noted at the time of the inspection. Petro Evaluations office was notified of this issue, and planned to mobilize field staff immediately to correct the issue. No other problems were noted at the time of the inspection. |
1173348181 | 2015-12-09 | Production Wells | No Violations | Inspected production well on 12/09/2015. The tank battery consists of 2-100 bbl steel tanks and 1-horizontal separator located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection. |
14960 | PL | No Violations | ||
1754771827 | 2017-02-02 | Preliminary Restoration | No Violations | Inspected production well on 02/02/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
For data sources see[9]