X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-25055

Well Details

Well ID: 34-169-25055
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Congress Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: MEISNER H #1
License Status: Producing
License Date: 1995-07-17
Spud Date: 1995-09-05
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1995-09-12
Well Total Depth: 5301.00 ft
Configuration: Vertical
Latitude: 40.940000
Longitude: -82.040000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1995-07-17 182 BELDEN & BLAKE CO GeoDate 7/17/95
Oil and Gas 1995-07-17 Issued Date 7/17/95 Expired Date 7/16/96 Acres 0040000 Tool Type RTAF Proposed Formation COPPER RIDGE Proposed Depth 05301 Proposed Drill Depth 05301
Original Spud 1995-09-05
Completed 1995-09-12
Reached Total Depth 1995-09-12
Completion Report Received 1995-09-22
Construction Permit Expires 1996-07-16
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5202 0
5202 0
2006-09-11 5247 5257 40
5247 5257 40
5202 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 500 Gal 0 TREATED W/500 GAL 15% FE ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION 16302.00 817.00 130
1996 BELDEN & BLAKE CORPORATION 175202.00 3568.00 335
1997 BELDEN & BLAKE CORPORATION 142486.00 1945.00 339
1998 BELDEN & BLAKE CORPORATION 53682.00 656.00 255
1999 BELDEN & BLAKE CORPORATION 33731.00 618.00 351
2000 BELDEN & BLAKE CORPORATION 23125.00 938.00 361
2001 BELDEN & BLAKE CORPORATION 17433.00 1211.00 358
2002 BELDEN & BLAKE CORPORATION 12911.00 1022.00 360
2003 BELDEN & BLAKE CORPORATION 9223.00 803.00 358
2004 BELDEN & BLAKE CORPORATION 7611.00 1078.00 363
2005 BELDEN & BLAKE CORPORATION 7052.00 1051.00 362
2006 BELDEN & BLAKE CORPORATION 7488.00 702.00 362
2007 ENERVEST OPERATING LLC 6241.00 992.00 365
2008 ENERVEST OPERATING LLC 7309.00 1345.00 365
2009 ENERVEST OPERATING LLC 20825.00 2483.00 365
2010 ENERVEST OPERATING LLC 9780.00 707.00 365
2011 ENERVEST OPERATING LLC 7320.00 520.00 0
2012 ENERVEST OPERATING LLC 4437.00 592.00 366
2013 ENERVEST OPERATING LLC 5266.00 585.00 365
2014 ENERVEST OPERATING LLC 5263.00 728.00 365
2015 ENERVEST OPERATING LLC 4463.00 481.00 365
2016 ENERVEST OPERATING LLC 4949.00 504.00 366
2017 ENERVEST OPERATING LLC 5842.00 457.00 365
2018 ENERVEST OPERATING LLC 5075.00 362.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION Brine 0 130
1996 BELDEN & BLAKE CORPORATION Brine 127 335
1997 BELDEN & BLAKE CORPORATION Brine 1 339
1998 BELDEN & BLAKE CORPORATION Brine 0 255
1999 BELDEN & BLAKE CORPORATION Brine 0 351
2000 BELDEN & BLAKE CORPORATION Brine 0 361
2001 BELDEN & BLAKE CORPORATION Brine 7 358
2002 BELDEN & BLAKE CORPORATION Brine 0 360
2003 BELDEN & BLAKE CORPORATION Brine 42 358
2004 BELDEN & BLAKE CORPORATION Brine 87 363
2005 BELDEN & BLAKE CORPORATION Brine 61 362
2006 BELDEN & BLAKE CORPORATION Brine 47 362
2007 ENERVEST OPERATING LLC Brine 87 365
2008 ENERVEST OPERATING LLC Brine 980 365
2009 ENERVEST OPERATING LLC Brine 1576 365
2010 ENERVEST OPERATING LLC Brine 720 365
2011 ENERVEST OPERATING LLC Brine 784
2012 ENERVEST OPERATING LLC Brine 1153 366
2013 ENERVEST OPERATING LLC Brine 922 365
2014 ENERVEST OPERATING LLC Brine 759 365
2015 ENERVEST OPERATING LLC Brine 649 365
2016 ENERVEST OPERATING LLC Brine 593 366
2017 ENERVEST OPERATING LLC Brine 489 365
2018 ENERVEST OPERATING LLC Brine 480 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1028285723 2018-11-13 0:00 PW No Violations
-1103687445 2017-3-8 0:00:0 PL No Violations
-1187611560 2016-11-29 0:00 PW No Violations
-1602536186 2011-9-28 0:00: PW No Violations 2.00
-1671650737 2012-11-8 0:00: PW No Violations
-445428406 2011-10-5 0:00: PW No Violations 2.00
-531960967 2016-11-29 0:00 PL No Violations
-789903742 2013-4-9 0:00:0 PW No Violations 0.50
-842719656 2011-10-5 0:00: PW No Violations 2.00
-925465901 2011-10-5 0:00: PW No Violations 2.00
-963017250 2018-3-15 0:00: PW No Violations
0000006637 Preliminary Restoration No Violations PASSED Y WITNESSED 10/31/95 INSPECTOR MARK MORELAND DATE 10/3119/95 DATA FROM OLD VAX INFO
0027681307 2017-10-27 Production Wells No Violations Inspected production well on 10/27/2017 to follow-up on a previously-issued compliance notice. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; 1-heater unit is located within a separate earthen dike nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. As proper well identification has been posted and no further problems were noted at the time of the inspection, the compliance notice should be closed out.
0037963651 2011-09-27 Production Wells No Violations There are three wells which are close enough to the complaint area to be inspected initially. Found several production tanks which had just been replaced. Check several cycles from the seperator and did not detect any natural gas odor. Checked additional wells in the area to try and locate gas leak. I did not locate the source of the reported leak/odor.
0112382419 2013-04-24 Production Wells No Violations Checking well site for Columbus. NOV for signage was resolved 10/19/2011. I inspected well on 4/9 and today, signage is still in place. Weather has taken a small toll on numbers, left well tender note to freshen up the name, permit number, etc.
0193675474 2017-03-08 Production Wells No Violations Inspected production well on 03/08/2017. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike; 1-heater unit is located within a separate earthen dike nearby. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0445428406 2011-10-05 Production Wells No Violations FOLLOW UP TO NOV # 1318343666 While looking for gas leak I found that there has been a spill inside the dike at the well head. Contact Enervest and advise of approximately 10 gallons of oil released on area approximately 14 x 8. I was told that someon
0531960967 2016-11-29 Preliminary Restoration No Violations Inspected production well on 11/29/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0585721209 2011-09-28 Production Wells Violations Noted FOLLOW UP TO NOV # 1317751115 Received a call from Bob Wright (West Salem Fire Dept.) who reported that they responded to gas complaint. Bob told me that he did find an odor of gas near this tank battery but the tanks did not have proper ID. I completed an inspection of the tanks and seperator and did not find any gas odor today. I was present for several cycles where the well flowed to the seperator and into the tanks but I did not detect any gas odor. I did not find any identification at the well or tank battery - will notify owner.
0635738659 2014-11-19 Production Wells No Violations Pumping unit well that appears to have no issues.
0781728212 2013-07-31 Production Wells No Violations NOV for signage previously cleared. No other problems at time of inspection.
0789903742 2013-04-09 Production Wells No Violations Legible signage is in place. No other problems noted at time of inspection.
0842719656 2011-10-05 Production Wells No Violations FOLLOW UP TO NOV # 1318343666 While looking for gas leak I found that there has been a spill inside the dike at the well head. Contact Enervest and advise of approximately 10 gallons of oil released on area approximately 14 x 8. I was told that someone would be dispatched very soon. Met pumper on site and went over clean up and advise of gas complaint.
0925465901 2011-10-05 Production Wells No Violations FOLLOW UP TO NOV # -445428406 FOLLOW UP TO NOV # 1318343666 While looking for gas leak I found that there has been a spill inside the dike at the well head. Contact Enervest and advise of approximately 10 gallons of oil released on area approximately 14 x 8. I was told that someon
0963017250 2018-03-15 Production Wells No Violations Inspected production well on 03/15/2018. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; 1-heater unit is located nearby. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1028285723 2018-11-13 Production Wells No Violations Inspected production well on 11/13/2018. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; 1-heater unit is located within a separate earthen dike nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1103687445 2017-03-08 Preliminary Restoration No Violations Inspected production well on 03/08/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
112382419 2013-4-24 0:00: PW No Violations 0.50
1128408425 2011-09-28 Production Wells No Violations Check this well along with other wells in the area and could nopt locate any gas odor or leaks.
1187611560 2016-11-29 Production Wells No Violations Inspected production well on 11/29/2016. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator, located within an earthen dike; 1-heater unit is located nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1295323651 2011-09-28 Production Wells No Violations FOLLOW UP TO NOV # 1317751115 Received a call from Bob Wright (West Salem Fire Dept.) who reported that they responded to gas complaint. Bob told me that he did find an odor of gas near this tank battery but the tanks did not have proper ID. I complete
1317751115 2011-09-28 Production Wells Violations Noted Received a call from Bob Wright (West Salem Fire Dept.) who reported that they responded to gas complaint. Bob told me that he did find an odor of gas near this tank battery but the tanks did not have proper ID. I completed an inspection of the tanks and seperator and did not find any gas odor today. I was present for several cycles where the well flowed to the seperator and into the tanks but I did not detect any gas odor. I did not find any identification at the well or tank battery - will notify owner.
1318343666 2011-10-05 Production Wells Violations Noted While looking for gas leak I found that there has been a spill inside the dike at the well head. Contact Enervest and advise of approximately 10 gallons of oil released on area approximately 14 x 8. I was told that someone would be dispatched very soon. Met pumper on site and went over clean up and advise of gas complaint.
1325255560 2016-02-23 Production Wells No Violations Inspected production well on 02/23/2016. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike; 1-heater is located nearby. The dike needs built-up on the back side in order to effectively serve as containment in case of a release. The well is equipped with a pump jack with an electric motor. A stuffing box leak was noted at the wellhead, which will need to be cleaned-up. Bill, Enervests pumper, was notified of these issues and will have them addressed promptly. Well identification is clearly displayed at both the tank battery and the wellhead. No other problems were noted at the time of the inspection.
1379633521 2011-10-19 Production Wells No Violations Identification has been posted and clean up is complete. Violation corrected.
1602536186 2011-09-28 Production Wells No Violations FOLLOW UP TO NOV # 1295323651 FOLLOW UP TO NOV # 1317751115 Received a call from Bob Wright (West Salem Fire Dept.) who reported that they responded to gas complaint. Bob told me that he did find an odor of gas near this tank battery but the tanks did not have proper ID. I complete
1671650737 2012-11-08 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
193675474 2017-3-8 0:00:0 PW No Violations
27681307 2017-10-27 0:00 PW No Violations
37963651 2011-9-27 0:00: PW No Violations 2.50
585721209 2011-9-28 0:00: PW No Violations 2.00
635738659 2014-11-19 0:00 PW No Violations 0.50
6637 PL No Violations
781728212 2013-7-31 0:00: PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0585721209 US-OH-126581 2017-04-27 Failure to legibly identify well
1317751115 US-OH-109079 2011-10-04 Failure to legibly identify well
1318343666 US-OH-109090 2011-10-11 Well operation causing pollution and contamination

For data sources see[9]

References