34-169-25060

Well Details

Well ID: 34-169-25060
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Canaan Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: WOLF RICHARD & JUDY
License Status: Producing
License Date: 1995-08-08
Spud Date: 1995-10-01
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1995-10-06
Well Total Depth: 5432.00 ft
Configuration: Vertical
Latitude: 40.950000
Longitude: -81.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1995-08-08 Issued Date 8/8/95 Expired Date 8/7/96 Acres 0079140 Tool Type RTAF Proposed Formation CL/TREMPEALEAU Proposed Depth 05432 Proposed Drill Depth 05432
Original Spud 1995-09-30
Completed 1995-10-06
Reached Total Depth 1995-10-06
CO 1995-11-16 461 OBERMILLER PAUL J GeoDate 8/8/95
Completion Report Received 1996-03-25
Construction Permit Expires 1996-08-07
Change of Owner 2013-09-12 Operator changed from 461, OBERMILLER PAUL J to 627, KENOIL
Change of Owner 2017-06-14 Operator changed from 627, KENOIL to 337, HARLEY DRILLING & PRODUCING
Record Last Modified 2017-06-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5428 0
5428 0
5428 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 NONOE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 OBERMILLER PAUL J 0.00 0.00 0
1996 OBERMILLER PAUL J 145331.00 477.00 365
1997 OBERMILLER PAUL J 30392.00 308.00 365
1998 OBERMILLER PAUL J 6878.00 150.00 365
1999 OBERMILLER PAUL J 2963.00 74.00 365
2000 OBERMILLER PAUL J 640.00 0.00 365
2001 OBERMILLER PAUL J 594.00 156.00 365
2002 OBERMILLER PAUL J 3658.00 158.00 365
2003 OBERMILLER PAUL J 3331.00 78.00 365
2004 OBERMILLER PAUL J 3171.00 119.00 365
2005 OBERMILLER PAUL J 2501.00 0.00 365
2006 OBERMILLER PAUL J 1737.00 84.00 365
2007 OBERMILLER PAUL J 1708.00 0.00 365
2008 OBERMILLER PAUL J 1398.00 77.00 365
2009 OBERMILLER PAUL J 1299.00 0.00 365
2010 OBERMILLER PAUL J 1250.00 68.00 365
2011 OBERMILLER PAUL J 1236.00 0.00 365
2012 OBERMILLER PAUL J 1268.00 60.00 366
2013 OBERMILLER PAUL J 865.00 42.00 365
2014 KENOIL LLC 871.00 0.00 365
2015 KENOIL LLC 941.00 0.00 365
2016 KENOIL LLC 1084.00 0.00 365
2017 HARLEY DRILLING & PRODUCING LT 171.00 0.00 365
2018 HARLEY DRILLING & PRODUCING LT 856.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 OBERMILLER PAUL J Brine 1490 0
1996 OBERMILLER PAUL J Brine 0 365
1997 OBERMILLER PAUL J Brine 0 365
1998 OBERMILLER PAUL J Brine 0 365
1999 OBERMILLER PAUL J Brine 0 365
2000 OBERMILLER PAUL J Brine 0 365
2001 OBERMILLER PAUL J Brine 0 365
2002 OBERMILLER PAUL J Brine 0 365
2003 OBERMILLER PAUL J Brine 0 365
2004 OBERMILLER PAUL J Brine 0 365
2005 OBERMILLER PAUL J Brine 0 365
2006 OBERMILLER PAUL J Brine 0 365
2007 OBERMILLER PAUL J Brine 0 365
2008 OBERMILLER PAUL J Brine 0 365
2009 OBERMILLER PAUL J Brine 0 365
2010 OBERMILLER PAUL J Brine 0 365
2011 OBERMILLER PAUL J Brine 0 365
2012 OBERMILLER PAUL J Brine 0 366
2013 OBERMILLER PAUL J Brine 0 365
2014 KENOIL LLC Brine 0 365
2015 KENOIL LLC Brine 0 365
2016 KENOIL LLC Brine 7 365
2017 HARLEY DRILLING & PRODUCING LT Brine 0 365
2018 HARLEY DRILLING & PRODUCING LT Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1202739335 2020-6-19 0:00: PW No Violations
-1329591908 2015-11-2 0:00: PW No Violations
-1373883950 2019-9-27 0:00: PW No Violations
-1397372118 2014-8-22 0:00: PW No Violations 0.50
-1981312474 2018-6-1 0:00:0 PW No Violations
-445098263 2017-1-30 0:00: PW No Violations
-506824940 2015-8-27 0:00: PW No Violations 0.50
-715994297 2013-7-31 0:00: PW No Violations 0.50
0000003265 Preliminary Restoration No Violations PASSED Y WITNESSED 7/18/96 INSPECTOR MARK MORELAND DATE 07/1819/96 DATA FROM OLD VAX INFO
0445098263 2017-01-30 Production Wells No Violations Inspected production well on 01/30/2017. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0506824940 2015-08-27 Production Wells No Violations This producing pumping unit well has no apparent problems nor compliance issues at this time.
0715994297 2013-07-31 Production Wells No Violations This is a pump jack well. No apparent problems at this time.
1329591908 2015-11-02 Production Wells No Violations Inspected production well on 11/02/2015. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1397372118 2014-08-22 Production Wells No Violations This is a pumping unit well. There are no obvious problems at time of inspection.
1635556598 2017-01-30 Preliminary Restoration No Violations Inspected production well on 01/30/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1981312474 2018-06-01 Production Wells No Violations Inspected production well on 06/01/2018. The tank battery consists of 1-100 bbl steel tank, 1-vertical separator, 1-drip, 1-meter with a drip and regulator, and 1-meter box, located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
3265 PL No Violations

For data sources see[9]

References