Well Details

Well ID: 34-169-25217
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: CUTTER OIL LLC
Well Pad ID:
Farm/Lease Name: MAXWELL UNIT
License Status: Producing
License Date: 1997-09-30
Spud Date: 1997-10-03
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 1997-10-10
Well Total Depth: 5550.00 ft
Configuration: Vertical
Latitude: 40.850000
Longitude: -81.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1997-09-30 Proposed Formations:TREMPEALEAU, Issued Date:9/30/97, Expired Date:9/30/98 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1997-10-03 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.
Completed 1997-10-10 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.
Reached Total Depth 1997-10-10 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.
Completion Report Received 1998-03-12 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.
Construction Permit Expires 1998-09-29 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.
Correction to Well 2011-07-22 CORRECTION TO LOCATION INFORMATION: FOOTAGE= 598'SL & 663'EL OF SW QTR., SEC. 18; X= 2,142,459; Y= 435,085; ELEV.= 1148'. UNIT SIZE INCREASED TO 187.17 ACRES.
Change of Owner 2013-09-03 Operator changed from 1249, CUTTER OIL CO to 9178, CUTTER OIL LLC
Record Last Modified 2017-02-15 REVISED UNIT 11-21-97: UNIT CHANGE ONLY.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-05-29 5492 5503 28
5492 5503 28
5492 5503 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 18 1500 Gal 0 FE ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 CUTTER OIL COMPANY 0.00 1258.00 33
1998 CUTTER OIL COMPANY 11983.00 25854.00 365
1999 CUTTER OIL COMPANY 36808.00 14831.00 365
2000 CUTTER OIL COMPANY 52633.00 7325.00 365
2001 CUTTER OIL COMPANY 17173.00 3685.00 365
2002 CUTTER OIL COMPANY 7325.00 2407.00 365
2003 CUTTER OIL COMPANY 3931.00 793.00 365
2004 CUTTER OIL COMPANY 707.00 226.00 365
2005 CUTTER OIL COMPANY 3118.00 433.00 365
2006 CUTTER OIL COMPANY 994.00 406.00 365
2007 CUTTER OIL COMPANY 1767.00 743.00 365
2008 CUTTER OIL COMPANY 1820.00 1505.00 365
2009 CUTTER OIL COMPANY 17248.00 5126.00 365
2010 CUTTER OIL COMPANY 12264.00 3850.00 365
2011 CUTTER OIL COMPANY 11909.00 3223.00 365
2012 CUTTER OIL COMPANY 11089.00 2337.00 366
2013 CUTTER OIL COMPANY 9943.00 2060.00 365
2014 CUTTER OIL LLC 12783.00 4175.00 365
2015 CUTTER OIL LLC 8987.00 2736.00 365
2016 CUTTER OIL LLC 9781.00 2458.00 365
2017 CUTTER OIL LLC 8852.00 2585.00 365
2018 CUTTER OIL LLC 7576.00 2431.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 CUTTER OIL COMPANY Brine 1675 33
1998 CUTTER OIL COMPANY Brine 0 365
1999 CUTTER OIL COMPANY Brine 0 365
2000 CUTTER OIL COMPANY Brine 0 365
2001 CUTTER OIL COMPANY Brine 0 365
2002 CUTTER OIL COMPANY Brine 0 365
2003 CUTTER OIL COMPANY Brine 0 365
2004 CUTTER OIL COMPANY Brine 78 365
2005 CUTTER OIL COMPANY Brine 0 365
2006 CUTTER OIL COMPANY Brine 0 365
2007 CUTTER OIL COMPANY Brine 0 365
2008 CUTTER OIL COMPANY Brine 102 365
2009 CUTTER OIL COMPANY Brine 0 365
2010 CUTTER OIL COMPANY Brine 0 365
2011 CUTTER OIL COMPANY Brine 0 365
2012 CUTTER OIL COMPANY Brine 0 366
2013 CUTTER OIL COMPANY Brine 75 365
2014 CUTTER OIL LLC Brine 30 365
2015 CUTTER OIL LLC Brine 0 365
2016 CUTTER OIL LLC Brine 0 365
2017 CUTTER OIL LLC Brine 0 365
2018 CUTTER OIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1840179269 2009-10-9 0:00: PW No Violations 0.70
-1887272308 2013-7-30 0:00: PW No Violations 0.50
-1925725131 2017-1-13 0:00: PL No Violations
-1958755676 2004-2-5 0:00:0 PW No Violations 1.00
-1998073405 2018-11-14 0:00 PW No Violations
-2023804971 2018-2-8 0:00:0 PW No Violations
-282329746 2019-7-16 0:00: PW No Violations
-408043213 2014-7-14 0:00: PW No Violations 0.50
-496867938 2016-7-14 0:00: PW No Violations
-632985243 2017-10-25 0:00 PW No Violations
-760025400 2020-4-8 0:00:0 PW No Violations
-83561956 2012-11-30 0:00 PW No Violations
-953526073 2013-5-20 0:00: PW No Violations 0.50
0083561956 2012-11-30 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0401220858 2007-01-18 Production Wells Violations Noted The identification is missing on this well .
0408043213 2014-07-14 Production Wells No Violations This is a pumpig unit well. There are no apparent problems at this time.
0496867938 2016-07-14 Production Wells No Violations Inspected production well on 07/14/2016. The tank battery consists of 4-210 bbl steel tanks, 1-100 bbl steel tank, and 2-horizontal separators, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0632985243 2017-10-25 Production Wells No Violations Inspected production well on 10/25/2017 to follow-up on a previously-issued compliance notice. The tank battery consists of 2-210 bbl steel tanks, 1-100 bbl steel tank (shared), and 1-horizontal separator with a drip and meter box, located within an earthen dike; the diked area is shared with the tank battery for the Maxwell #7 well (PN: 169-25664). The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. As proper well identification has been posted and no further problems noted at the time of the inspection, the compliance notice should be closed-out.
0953526073 2013-05-20 Production Wells No Violations Appears to be in compliance. NOV # 1051278293 resolved.
1051278293 2004-02-05 Production Wells Violations Noted Well site is graded and seeded.
1304398212 2017-01-13 Production Wells No Violations Inspected production well on 01/13/2017. The tank battery consists of 2-210 bbl steel tanks, 1-100 bbl steel tank (shared with the Maxwell #7 well; PN: 169-25664), and 1-horizontal separator, located within an earthen dike; the diked area is shared with the tank battery for the Maxwell #7 well (PN: 169-25664). The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1350933918 2015-11-19 Production Wells No Violations Inspected production well on 11/19/2015. The tank battery consists of 4-210 bbl steel tanks, 1-100 bbl steel tank, and 2-horizontal separators located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1360412307 2004-02-05 Production Wells No Violations FOLLOW UP TO NOV # 1051278293 Well site is graded and seeded.
1362506614 2004-02-05 Production Wells No Violations FOLLOW UP TO NOV # 1051278293 Well site is graded and seeded.
1509768314 2013-04-12 Production Wells No Violations Appears to be in compliance. No violations noted at this time. NOV 1051278293 is resolved with this inspection.
1840179269 2009-10-09 Production Wells No Violations Id has been posted , no leaks or spills at well or tanks
1887272308 2013-07-30 Production Wells No Violations NOV for no signage is resloved. No apparent problems at this time.
1925725131 2017-01-13 Preliminary Restoration No Violations Inspected production well on 01/13/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1958755676 2004-02-05 Production Wells No Violations FOLLOW UP TO NOV # 1360412307 FOLLOW UP TO NOV # 1051278293 Well site is graded and seeded.
1998073405 2018-11-14 Production Wells No Violations Inspected production well on 11/14/2018. The tank battery consists of 2-210 bbl steel tanks, 1-100 bbl steel tank (shared), and 1-horizontal separator with a drip and meter box, located within an earthen dike; the diked area and noted equipment are shared with the tank battery for the Maxwell #7 well (PN: 169-25664). The well is equipped with a pump jack with an electric motor; the wellhead is located within a small earthen dike. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
2023804971 2018-02-08 Production Wells No Violations Inspected production well on 02/08/2018. The tank battery consists of 2-210 bbl steel tanks, 1-100 bbl steel tank (shared), and 1-horizontal separator with a drip and meter box, located within an earthen dike (shared). The 100 bbl steel tank and diked area are shared with the Maxwell #7 well (PN: 169-25664). The well is equipped with a pump jack with an electric motor; the wellhead is located within a small earthen dike. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
401220858 2007-1-18 0:00: PW No Violations 0.70

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0401220858 US-OH-124275 2007-01-25 Failure to legibly identify well
1051278293 US-OH-100862 2004-02-06 Failure to legibly identify well

For data sources see[9]