If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25241 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.87,"lon":-82,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Chester Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: MCCONAHAY | |
License Status: Producing | |
License Date: 1998-03-11 | |
Spud Date: 1998-03-13 | |
Spud Drilling Contractor: UNION DRLG | |
Final Drill Date: 1998-03-22 | |
Well Total Depth: 5346.00 ft | |
Configuration: Directional | |
Latitude: 40.870000 | |
Longitude: -82.000000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1998-03-11 | Proposed Formations:QUEENSTON thru MT. SIMON, Issued Date:3/11/98, Expired Date:3/11/99 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 1998-03-13 | RBDMS Rec |
Completed | 1998-03-22 | RBDMS Rec |
Reached Total Depth | 1998-03-22 | RBDMS Rec |
Completion Report Received | 1998-05-06 | RBDMS Rec |
Correction to Well | 1998-06-05 | CHANGE TARGET LOCATION TO: 802'NL & 505'EL OF NW 1/4 SEC 13(E). CHANGE X & Y COORDS. X = 2,136,650, Y = 438,800. CHANGE ELEVATION TO: 890 |
Construction Permit Expires | 1999-03-11 | RBDMS Rec |
Change of Owner | 2007-04-27 | Operator changed from 28, CGAS EXPLORATION to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1998-07-29 | 5196 | 5234 | 62 |
5196 | 5234 | 62 | |
5196 | 5234 | 62 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1000 Gal | 0 | ALSO USED 114 BBL WATER |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | CGAS EXPLORATION | 191946.00 | 662.00 | 365 |
1999 | CGAS EXPLORATION | 290768.00 | 285.00 | 365 |
2000 | CGAS EXPLORATION | 95655.00 | 66.00 | 365 |
2001 | CGAS EXPLORATION | 23823.00 | 0.00 | 365 |
2002 | CGAS EXPLORATION | 9423.00 | 0.00 | 365 |
2003 | CGAS EXPLORATION | 9586.00 | 0.00 | 365 |
2004 | CGAS EXPLORATION | 7665.00 | 0.00 | 365 |
2005 | CGAS EXPLORATION | 2528.00 | 0.00 | 365 |
2006 | CGAS EXPLORATION | 4032.00 | 0.00 | 365 |
2007 | ENERVEST OPERATING LLC | 3050.00 | 0.00 | 365 |
2008 | ENERVEST OPERATING LLC | 725.00 | 0.00 | 365 |
2009 | ENERVEST OPERATING LLC | 20088.00 | 86.00 | 365 |
2010 | ENERVEST OPERATING LLC | 15642.00 | 52.00 | 365 |
2011 | ENERVEST OPERATING LLC | 6430.00 | 0.00 | 0 |
2012 | ENERVEST OPERATING LLC | 4583.00 | 0.00 | 366 |
2013 | ENERVEST OPERATING LLC | 1909.00 | 44.00 | 365 |
2014 | ENERVEST OPERATING LLC | 1158.00 | 0.00 | 365 |
2015 | ENERVEST OPERATING LLC | 595.00 | 0.00 | 193 |
2016 | ENERVEST OPERATING LLC | 623.00 | 0.00 | 180 |
2017 | ENERVEST OPERATING LLC | 553.00 | 0.00 | 189 |
2018 | ENERVEST OPERATING LLC | 527.00 | 0.00 | 202 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | CGAS EXPLORATION | Brine | 50 | 365 |
1999 | CGAS EXPLORATION | Brine | 81 | 365 |
2000 | CGAS EXPLORATION | Brine | 30 | 365 |
2001 | CGAS EXPLORATION | Brine | 0 | 365 |
2002 | CGAS EXPLORATION | Brine | 77 | 365 |
2003 | CGAS EXPLORATION | Brine | 0 | 365 |
2004 | CGAS EXPLORATION | Brine | 0 | 365 |
2005 | CGAS EXPLORATION | Brine | 0 | 365 |
2006 | CGAS EXPLORATION | Brine | 0 | 365 |
2007 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2008 | ENERVEST OPERATING LLC | Brine | 64 | 365 |
2009 | ENERVEST OPERATING LLC | Brine | 1923 | 365 |
2010 | ENERVEST OPERATING LLC | Brine | 1070 | 365 |
2011 | ENERVEST OPERATING LLC | Brine | 828 | |
2012 | ENERVEST OPERATING LLC | Brine | 523 | 366 |
2013 | ENERVEST OPERATING LLC | Brine | 435 | 365 |
2014 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2015 | ENERVEST OPERATING LLC | Brine | 0 | 193 |
2016 | ENERVEST OPERATING LLC | Brine | 0 | 180 |
2017 | ENERVEST OPERATING LLC | Brine | 0 | 189 |
2018 | ENERVEST OPERATING LLC | Brine | 0 | 202 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1001072392 | 2016-10-19 0:00 | PL | No Violations | |
-1652230606 | 2015-6-23 0:00: | PW | No Violations | 0.50 |
-1658122605 | 2017-2-1 0:00:0 | PW | No Violations | |
-518069722 | 2012-11-30 0:00 | PW | No Violations | |
0518069722 | 2012-11-30 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
0581940787 | 2016-10-19 | Production Wells | No Violations | Inspected production well on 10/19/2016. The tank battery consists of 1-210 bbl steel tank and 1-100 bbl steel tank, located within an earthen dike; 1-vertical separator is located within a separate earthen dike. The 210 bbl tank is rusted through in spots, and needs to be removed. Tim McConaha, Enervests field superintendent, was notified of this issue and will address it with management. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No other problems were noted at the time of the inspection. |
1001072392 | 2016-10-19 | Preliminary Restoration | No Violations | Inspected production well on 10/19/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1093123266 | 2014-07-15 | Production Wells | No Violations | This pumping unit well has no apparent problems at this time. |
1432986072 | 2017-02-01 | Preliminary Restoration | No Violations | Inspected production well on 02/01/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1652230606 | 2015-06-23 | Production Wells | No Violations | Pumping unit well with no apparent problems at this time. |
1658122605 | 2017-02-01 | Production Wells | No Violations | Inspected production well on 02/01/2017. The tank battery consists of 1-210 bbl steel tank and 1-100 bbl steel tank, located within an earthen dike; 1-vertical separator is located within a separate earthen dike nearby. The 210 bbl steel tank is rusted through in several spots, and must be removed. Bill Gallatin with Enervest was notified of this issue, and plans to address it when moving the tank battery this spring/summer. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No other problems were noted at the time of the inspection. |
1681568139 | 2016-03-09 | Production Wells | No Violations | Inspected production well on 03/09/2016. The tank battery consists of 1-210 bbl steel tank and 1-100 bbl steel tank located within an earthen dike; 1-vertical separator is located in a separate earthen dike nearby. The 210 bbl steel tank is rusted through and not in use, and it must be removed. Bill Barns, pumper for Enervest, was notified of this issue and will pass it along to management to be addressed. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No other problems were noted at the time of the inspection. |
581940787 | 2016-10-19 0:00 | PW | No Violations | |
iANGE00161 | 1998-06-03 | Preliminary Restoration | No Violations | |
iANGE001614 | 1998-6-3 0:00:0 | PL | No Violations |
For data sources see[9]