X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-25268

Well Details

Well ID: 34-169-25268
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Franklin Township
Operator Name: FRANKLIN GAS & OIL CO LLC
Well Pad ID:
Farm/Lease Name: GILMOR-BRICKER
License Status: Producing
License Date: 1998-11-03
Spud Date: 1998-12-02
Spud Drilling Contractor: UNION DRLG
Final Drill Date: 1998-12-10
Well Total Depth: 5588.00 ft
Configuration: Vertical
Latitude: 40.720000
Longitude: -81.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1998-11-03 Proposed Formations:TREMPEALEAU, Issued Date:11/3/98, Expired Date:11/3/99 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
Original Spud 1998-12-02 RBDMS Rec
Completed 1998-12-10 RBDMS Rec
Reached Total Depth 1998-12-10 RBDMS Rec
Completion Report Received 1999-06-07 RBDMS Rec
Construction Permit Expires 1999-11-03 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-09-07 5398 5442 72
5398 5442 72
5398 5442 72

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 2300 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 JAMES R SMAIL INC 0.00 159.00 365
1999 FRANKLIN GAS & OIL CO LLC 14993.00 12521.00 0
2000 FRANKLIN GAS & OIL CO LLC 29987.00 19314.00 0
2001 FRANKLIN GAS & OIL CO LLC 32270.00 18497.00 365
2002 FRANKLIN GAS & OIL CO LLC 38477.00 19022.00 0
2003 FRANKLIN GAS & OIL CO LLC 40493.00 14962.00 0
2004 FRANKLIN GAS & OIL CO LLC 43373.00 13566.00 0
2005 FRANKLIN GAS & OIL CO LLC 41808.00 11182.00 365
2006 FRANKLIN GAS & OIL CO LLC 47927.00 10972.00 365
2007 FRANKLIN GAS & OIL CO LLC 47758.00 8764.00 365
2008 FRANKLIN GAS & OIL CO LLC 54591.00 8179.00 365
2009 FRANKLIN GAS & OIL CO LLC 47654.00 7043.00 365
2010 FRANKLIN GAS & OIL CO LLC 40677.00 7155.00 365
2011 FRANKLIN GAS & OIL CO LLC 27906.00 6171.00 365
2012 FRANKLIN GAS & OIL CO LLC 20617.00 4367.00 366
2013 FRANKLIN GAS & OIL CO LLC 25846.00 5401.00 365
2014 FRANKLIN GAS & OIL CO LLC 36904.00 5782.00 365
2015 FRANKLIN GAS & OIL CO LLC 21660.00 3485.00 365
2016 FRANKLIN GAS & OIL CO LLC 9404.00 1797.00 365
2017 FRANKLIN GAS & OIL CO LLC 3376.00 874.00 365
2018 FRANKLIN GAS & OIL CO LLC 9424.00 1516.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 JAMES R SMAIL INC Brine 0 365
1999 FRANKLIN GAS & OIL CO LLC Brine 2720
2000 FRANKLIN GAS & OIL CO LLC Brine 30
2001 FRANKLIN GAS & OIL CO LLC Brine 0 365
2002 FRANKLIN GAS & OIL CO LLC Brine 30
2003 FRANKLIN GAS & OIL CO LLC Brine 0
2004 FRANKLIN GAS & OIL CO LLC Brine 0
2005 FRANKLIN GAS & OIL CO LLC Brine 0 365
2006 FRANKLIN GAS & OIL CO LLC Brine 0 365
2007 FRANKLIN GAS & OIL CO LLC Brine 80 365
2008 FRANKLIN GAS & OIL CO LLC Brine 0 365
2009 FRANKLIN GAS & OIL CO LLC Brine 5 365
2010 FRANKLIN GAS & OIL CO LLC Brine 0 365
2011 FRANKLIN GAS & OIL CO LLC Brine 50 365
2012 FRANKLIN GAS & OIL CO LLC Brine 0 366
2013 FRANKLIN GAS & OIL CO LLC Brine 0 365
2014 FRANKLIN GAS & OIL CO LLC Brine 0 365
2015 FRANKLIN GAS & OIL CO LLC Brine 0 365
2016 FRANKLIN GAS & OIL CO LLC Brine 0 365
2017 FRANKLIN GAS & OIL CO LLC Brine 0 365
2018 FRANKLIN GAS & OIL CO LLC Brine 160 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2131815449 2016-6-13 0:00: PW No Violations
-668642346 2018-7-19 0:00: PW No Violations
0130255358 2017-05-09 Production Wells No Violations Inspected production well on 05/09/2017. The tank battery consists of 2-210 bbl steel tanks and 1-1,550 gal plastic tank, located within an earthen dike; 1-horizontal separator is located within a separate earthen dike nearby. Both diked areas are located within locked metal fences. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor, located within a locked metal fence. No problems were noted at the time of the inspection.
0242494023 2015-07-27 Production Wells No Violations This pumping unit well, equipped with chemical injection, has no apparent problems nor compliance isues at this time.
0349795751 2017-05-09 Preliminary Restoration No Violations Inspected production well on 05/09/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0668642346 2018-07-19 Production Wells No Violations Inspected production well on 07/19/2018. The tank battery consists of 2-210 bbl steel tanks and 1-1,550 gal plastic tank, located within an earthen dike; the diked area is located within a locked metal fence. 1-horizontal separator with a drip, and 2-drips with 1-regulator are located within a separate earthen dike nearby; the diked area is also located within a locked metal fence. The well is equipped with a pump jack with an electric motor and 1-steel diesel tank, located within a locked metal fence. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection.
1136582298 2013-05-23 Production Wells No Violations This pump jack well was pumping at time of inspection. No apparent problems at this time.
1161391397 2020-5-5 0:00:0 PW No Violations
130255358 2017-5-9 0:00:0 PW No Violations
1403699765 2014-06-25 Production Wells No Violations This pumping unit well was in operation at time of inspection. There are no apparent problems at this time.
1582895876 2020-2-28 0:00: PW No Violations 0.50
2131815449 2016-06-13 Production Wells No Violations Inspected production well on 06/13/2016. The tank battery consists of 2-210 bbl steel tanks and 1-1,600 gal plastic tank, located within an earthen dike. The diked area is located within a locked metal fence. Well identification is clearly displayed at the tank battery. 1-horizontal separator is located within a separate earthen dike and locked metal fence nearby. The well is equipped with a pump jack with an electric motor, located within a locked metal fence. No problems were noted at the time of the inspection.
242494023 2015-7-27 0:00: PW No Violations 0.50
349795751 2017-5-9 0:00:0 PL No Violations
iDIAN00140 1999-05-17 Preliminary Restoration No Violations
iDIAN001407 1999-5-17 0:00: PL No Violations

For data sources see[9]

References