Well Details

Well ID: 34-169-25278
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Canaan Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: SAVAGE
License Status: Producing
License Date: 1999-03-30
Spud Date: 1999-04-29
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 1999-05-09
Well Total Depth: 5579.00 ft
Configuration: Vertical
Latitude: 40.910000
Longitude: -81.940000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-03-30 627 KENOIL Proposed Formation TREMPEALEAU Issued Date 3/30/99 Expired Date 3/29/00 6:00:00 AM
Original Spud 1999-04-29 RBDMS Rec
Completed 1999-05-09 RBDMS Rec
Reached Total Depth 1999-05-09 RBDMS Rec
Completion Report Received 1999-07-28 RBDMS Rec
Construction Permit Expires 2000-03-29 RBDMS Rec
Change of Owner 2017-09-13 Operator changed from 627, KENOIL to 337, HARLEY DRILLING & PRODUCING LTD
Record Last Modified 2017-09-13 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-10-22 5524 5534 21
5524 5534 21
5539 5544 11
5550 5558 17
1999-10-22 5539 5544 11
5524 5534 21
1999-10-22 5550 5558 17

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 KENOIL LLC 6846.00 57.00 0
2000 KENOIL LLC 9094.00 27.00 365
2001 KENOIL LLC 5096.00 0.00 365
2002 KENOIL LLC 5012.00 31.00 365
2003 KENOIL LLC 4391.00 0.00 365
2004 KENOIL LLC 3677.00 0.00 365
2005 KENOIL LLC 2419.00 24.00 365
2006 KENOIL LLC 2420.00 0.00 365
2007 KENOIL LLC 1925.00 0.00 365
2008 KENOIL LLC 1292.00 0.00 365
2009 KENOIL LLC 1289.00 22.00 365
2010 KENOIL LLC 1592.00 0.00 365
2011 KENOIL LLC 1674.00 18.00 0
2012 KENOIL LLC 1013.00 0.00 366
2013 KENOIL LLC 1386.00 0.00 365
2014 KENOIL LLC 1348.00 0.00 365
2015 KENOIL LLC 1289.00 0.00 365
2016 KENOIL LLC 651.00 0.00 365
2017 HARLEY DRILLING & PRODUCING LT 35.00 0.00 365
2018 HARLEY DRILLING & PRODUCING LT 746.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 KENOIL LLC Brine 436
2000 KENOIL LLC Brine 128 365
2001 KENOIL LLC Brine 82 365
2002 KENOIL LLC Brine 168 365
2003 KENOIL LLC Brine 132 365
2004 KENOIL LLC Brine 127 365
2005 KENOIL LLC Brine 62 365
2006 KENOIL LLC Brine 117 365
2007 KENOIL LLC Brine 90 365
2008 KENOIL LLC Brine 88 365
2009 KENOIL LLC Brine 94 365
2010 KENOIL LLC Brine 88 365
2011 KENOIL LLC Brine 78
2012 KENOIL LLC Brine 89 366
2013 KENOIL LLC Brine 98 365
2014 KENOIL LLC Brine 110 365
2015 KENOIL LLC Brine 137 365
2016 KENOIL LLC Brine 0 365
2017 HARLEY DRILLING & PRODUCING LT Brine 0 365
2018 HARLEY DRILLING & PRODUCING LT Brine 100 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1056660994 2014-5-16 0:00: PW No Violations 0.50
-184322385 2017-2-2 0:00:0 PL No Violations
-417203162 2017-2-2 0:00:0 PW No Violations
-929771606 2016-9-15 0:00: PW No Violations
0184322385 2017-02-02 Preliminary Restoration No Violations Inspected production well on 02/02/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0417203162 2017-02-02 Production Wells No Violations Inspected production well on 02/02/2017. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike; 1-underground brine vault is located within a separate earthen dike nearby. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0929771606 2016-09-15 Production Wells No Violations Inspected production well on 09/15/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. 1-underground brine vault is located within a separate earthen dike nearby. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0951715193 2018-05-22 Production Wells No Violations Inspected production well on 05/22/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-drip, 1-meter with a regulator, and 2-meter boxes, located within an earthen dike; 1-drip and 1-underground brine vault are located within a separate earthen dike nearby. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1056660994 2014-05-16 Production Wells No Violations This pumping unit well has no apparent problems at this time.
345672378 2020-4-23 0:00: PW No Violations
951715193 2018-5-22 0:00: PW No Violations
iDIAN00141 1999-07-06 Preliminary Restoration No Violations
iDIAN001412 1999-7-6 0:00:0 PL No Violations
iDIAN00217 1999-08-28 Preliminary Restoration No Violations
iDIAN002177 1999-8-28 0:00: PL No Violations

For data sources see[9]