34-169-25294

Well Details

Well ID: 34-169-25294
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Milton Township
Operator Name: MORTON SALT INC
Well Pad ID:
Farm/Lease Name: MORTON SALT {SMP # 4}
License Status: Final Restoration
License Date: 2009-09-09
Spud Date: 2006-08-03
Spud Drilling Contractor:
Final Drill Date: 1999-09-26
Well Total Depth: 2621.00 ft
Configuration: Vertical
Latitude: 40.950000
Longitude: -81.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-06-28 Proposed Formations:SALINA, Issued Date:6/28/99, Expired Date:6/27/00 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SM, Proposed Well Class:SMP
Original Spud 1999-09-16 PLUGGED AND ABANDONED - 10/15/2009 - TET
Completed 1999-09-26 PLUGGED AND ABANDONED - 10/15/2009 - TET
Reached Total Depth 1999-09-26 PLUGGED AND ABANDONED - 10/15/2009 - TET
Completion Report Received 1999-11-01 PLUGGED AND ABANDONED - 10/15/2009 - TET
APP 2005-08-08 Proposed Formations:SALINA, Issued Date:8/8/2005, Expired Date:8/8/2006 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SM, Proposed Well Class:SMP
Plugged Back 2006-08-03 PLUGGED AND ABANDONED - 10/15/2009 - TET
Last Compliance Report 2006-08-10 PLUGGED AND ABANDONED - 10/15/2009 - TET
APP 2009-09-09 Proposed Formations:SALINA, Issued Date:9/9/2009, Expired Date:9/9/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SM, Proposed Well Class:SMP
Plugged/Abandoned 2009-10-15 PLUGGED AND ABANDONED - 10/15/2009 - TET
Construction Permit Expires 2010-09-09 PLUGGED AND ABANDONED - 10/15/2009 - TET
Record Last Modified 2017-02-15 PLUGGED AND ABANDONED - 10/15/2009 - TET

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-09-14 2520 2590 0
2520 2590 0
2520 2590 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-135166706 2010-3-9 0:00:0 SM No Violations 1.00
-1596567455 2009-10-13 0:00 SM No Violations 1.50
-1611795323 2009-10-19 0:00 SM No Violations 1.00
-1689038723 2009-10-15 0:00 PB No Violations 10.50
-1761383914 2006-8-3 0:00:0 SM No Violations 3.50
-1990434173 2010-6-16 0:00: FR No Violations 1.00
-679566422 2003-12-9 0:00: SM No Violations
-86876942 2010-4-6 0:00:0 SM No Violations 1.00
-978551896 2006-8-2 0:00:0 SM No Violations 4.00
0086876942 2010-04-06 Solution Mining Project No Violations Final restoraton has not been completed
0135166706 2010-03-09 Solution Mining Project No Violations Pits are closed and area needs graded and seeded.Final not ready.
0679566422 2003-12-09 Solution Mining Project No Violations CHECKED ID - OK
0978551896 2006-08-02 Solution Mining Project No Violations Morton Salt is testing ,M.I.T. on this well .Wait on pump truck and then water .Next connect to well and could not fill well to surface .The well continued to leak off and not reach the top to the casing in order to continue test .Test failed and was decided at this time to place cement across the bridge plug and wait and test well again .
1210i46572 2002-03-27 Solution Mining Project No Violations Well appears ok. Accompanied by Tom T. & D ave H..
1210i4657201 2002-3-27 0:00: SM No Violations
1214641716 2006-08-04 Solution Mining Project No Violations Arrive today to Test M.I.T. again after Halliburton cemented bottom 200 ft. - Pump 8 inch casing up to 500 P.S.I and test passed .
1223622763 2013-10-23 Solution Mining Project No Violations There were no violations found at the time of inspection.
1293547870 2010-12-10 Final Restoration No Violations Check this well for Erica Freeman and found that it has been plugged and has correct info on well cap to meet final restoration requirements.
1596567455 2009-10-13 Solution Mining Project No Violations M.I.T. For 15 minute pressure test and test passed. Electric plug at 2400 ft and Halliburton set 200 ft plug on top of it to 2200 ft .
1611795323 2009-10-19 Solution Mining Project No Violations Cement is down 3 ft and there are no leaks at this time
1689038723 2009-10-15 Plug / Plug Back No Violations Tag top of plug at 2208 ft and Halliburton set all plugs thru 2 3/8 tubing in stages to surface .
1761383914 2006-08-03 Solution Mining Project No Violations Arrive today to set plug over the bridge plug .Bridge plug is at 2400 ft. and ran tubing to 2391 and Halliburton set 60 sacks from 2391 to 2191 thru tubing .Next pull up and reverse circulate tubing to make sure it was clear at that depth .
1902552368 2004-10-06 Solution Mining Project No Violations Andy Myers wanted to conduct a test on the annulus of this well today but test failed before it even got started.Tried to pressure up on both sides of the casing and could not get fluid to circulate for test to begin.Had problem down hole.I think that the cavern is now in communication and therefor well would not maintain pressure.
1990434173 2010-06-16 Final Restoration No Violations Check on restoration final and found that it meets requirements for final to be approved .

For data sources see[4]

References