Well Details

Well ID: 34-169-25329
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Chester Township
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name: HERSHEY TED
License Status: Producing
License Date: 2000-03-01
Spud Date: 2000-03-27
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 2000-03-30
Well Total Depth: 3201.00 ft
Configuration: Vertical
Latitude: 40.850000
Longitude: -82.110000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-03-01 Proposed Formations:CLINTON, Issued Date:03/01/2000, Expired Date:03/01/2001 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2000-03-27 RBDMS Rec
Completed 2000-03-30 RBDMS Rec
Reached Total Depth 2000-03-30 RBDMS Rec
Completion Report Received 2000-09-25 RBDMS Rec
Construction Permit Expires 2001-03-01 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-12-08 3049 3060 24
3049 3060 24
3049 3060 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 91500 Gal 37500 300 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2000 MFC DRILLING INC 577.00 0.00 365
2001 MFC DRILLING INC 0.00 0.00 365
2002 MFC DRILLING INC 3758.00 0.00 365
2003 MFC DRILLING INC 4199.00 0.00 365
2004 MFC DRILLING INC 4650.00 0.00 365
2005 MFC DRILLING INC 4104.00 0.00 365
2006 MFC DRILLING INC 3926.00 0.00 365
2007 MFC DRILLING INC 3931.00 0.00 365
2008 MFC DRILLING INC 3505.00 0.00 365
2009 MFC DRILLING INC 3215.00 0.00 365
2010 MFC DRILLING INC 2794.00 0.00 365
2011 MFC DRILLING INC 3097.00 0.00 365
2012 MFC DRILLING INC 2939.00 0.00 366
2013 MFC DRILLING INC 2602.00 0.00 365
2014 MFC DRILLING INC 2184.00 0.00 365
2015 MFC DRILLING INC 1881.00 0.00 365
2016 MFC DRILLING INC 1996.00 0.00 365
2017 MFC DRILLING INC 1783.00 0.00 365
2018 MFC DRILLING INC 1956.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2000 MFC DRILLING INC Brine 0 365
2001 MFC DRILLING INC Brine 62 365
2002 MFC DRILLING INC Brine 0 365
2003 MFC DRILLING INC Brine 58 365
2004 MFC DRILLING INC Brine 0 365
2005 MFC DRILLING INC Brine 0 365
2006 MFC DRILLING INC Brine 52 365
2007 MFC DRILLING INC Brine 0 365
2008 MFC DRILLING INC Brine 0 365
2009 MFC DRILLING INC Brine 0 365
2010 MFC DRILLING INC Brine 0 365
2011 MFC DRILLING INC Brine 0 365
2012 MFC DRILLING INC Brine 55 366
2013 MFC DRILLING INC Brine 0 365
2014 MFC DRILLING INC Brine 0 365
2015 MFC DRILLING INC Brine 0 365
2016 MFC DRILLING INC Brine 0 365
2017 MFC DRILLING INC Brine 0 365
2018 MFC DRILLING INC Brine 11 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1561595442 2018-5-25 0:00: PW No Violations
-1879407498 2016-5-31 0:00: PW No Violations
-2012169809 2015-7-7 0:00:0 PW No Violations 0.50
-299716359 2014-7-10 0:00: PW No Violations 0.50
-322587561 2020-8-25 0:00: PW No Violations
0299716359 2014-07-10 Production Wells No Violations This is a pumping unit well. There are no apparent problems at this time.
1170809228 2017-10-04 Preliminary Restoration No Violations Inspected production well on 10/04/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1486383792 2016-12-19 Preliminary Restoration No Violations Inspected production well on 12/19/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1561595442 2018-05-25 Production Wells No Violations Inspected production well on 05/25/2018. The tank battery consists of 1-100 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter with a regulator, located within a shallow earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1618319819 2016-12-19 Production Wells No Violations Inspected production well on 12/19/2016. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator - no earthen dike is present around the tank battery. Ted Hershey with MFC Drilling was notified of this issue and will address it as promptly as weather permits. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No other problems were noted at the time of the inspection.
1823863191 2017-10-04 Production Wells No Violations Inspected production well on 10/04/2017. The tank battery consists of 1-100 bbl steel tank, 1-vertical separator, 1-drip, and 1-meter, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1879407498 2016-05-31 Production Wells No Violations Inspected production well on 05/31/2016. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator; no dike is present. Ted Hershey, pumper for MFC Drilling, was notified of this issue and will address it promptly. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No other problems were noted at the time of the inspection.
2012169809 2015-07-07 Production Wells No Violations This is a pumping unit well that has no apparent problems nor compliance issues at time of inspection.
iDIAN00460 2000-06-15 Preliminary Restoration No Violations
iDIAN004603 2000-6-15 0:00: PL No Violations