34-169-25491

Well Details

Well ID: 34-169-25491
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Milton Township
Operator Name: KENOIL LLC
Well Pad ID:
Farm/Lease Name: DOTTERER
License Status: Producing
License Date: 2004-05-14
Spud Date: 2004-06-01
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-06-05
Well Total Depth: 3569.00 ft
Configuration: Vertical
Latitude: 40.950000
Longitude: -81.790000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-05-14 Proposed Formations:CLINTON, Issued Date:5/14/2004, Expired Date:5/14/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-06-01 RBDMS Rec
Completed 2004-06-05 RBDMS Rec
Reached Total Depth 2004-06-05 RBDMS Rec
Completion Report Received 2004-10-25 RBDMS Rec
Construction Permit Expires 2005-05-14 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-11-24 3379 3401 45
3379 3401 45
3379 3401 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 KENOIL LLC 460.00 75.00 365
2005 KENOIL LLC 1707.00 393.00 365
2006 KENOIL LLC 1059.00 139.00 365
2007 KENOIL LLC 1058.00 140.00 0
2008 KENOIL LLC 1246.00 108.00 365
2009 KENOIL LLC 1172.00 100.00 365
2010 KENOIL LLC 1411.00 128.00 365
2011 KENOIL LLC 1433.00 65.00 0
2012 KENOIL LLC 1415.00 101.00 366
2013 KENOIL LLC 901.00 60.00 365
2014 KENOIL LLC 338.00 0.00 365
2015 KENOIL LLC 85.00 35.00 365
2016 KENOIL LLC 55.00 0.00 365
2017 KENOIL LLC 1155.00 115.00 365
2018 KENOIL LLC 1668.00 55.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 KENOIL LLC Brine 239 365
2005 KENOIL LLC Brine 65 365
2006 KENOIL LLC Brine 0 365
2007 KENOIL LLC Brine 33
2008 KENOIL LLC Brine 17 365
2009 KENOIL LLC Brine 35 365
2010 KENOIL LLC Brine 6 365
2011 KENOIL LLC Brine 0
2012 KENOIL LLC Brine 0 366
2013 KENOIL LLC Brine 0 365
2014 KENOIL LLC Brine 0 365
2015 KENOIL LLC Brine 35 365
2016 KENOIL LLC Brine 0 365
2017 KENOIL LLC Brine 24 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1002133559 2005-2-15 0:00: PL No Violations 1.00
-1066014601 2016-12-1 0:00: PL No Violations
-1363738962 2015-3-12 0:00: PW No Violations 0.50
-1408999639 2017-6-14 0:00: PL No Violations
-1583989560 2017-6-14 0:00: PW No Violations
-1719643241 2016-5-26 0:00: PW No Violations
-221146782 2004-6-2 0:00:0 DD No Violations 4.50
-274803436 2004-6-1 0:00:0 DD No Violations 0.50
-318850057 2004-6-4 0:00:0 DD No Violations 1.50
-639378930 2016-12-1 0:00: PW No Violations
0221146782 2004-06-02 Drill / Deepen / Reopen No Violations Capstar Drilling set 409ft. 8 5/8 casing c/w 175 sks.
0274803436 2004-06-01 Drill / Deepen / Reopen No Violations Had meeting set today with Ron Grosjean and Paul Hessey to review permit info and two stage cement job required if they incounter brine flow from Morton Salt.
0318850057 2004-06-04 Drill / Deepen / Reopen No Violations Capstar Drilling at 2742 ft. and past the salt section and did not encounter the flow which would require two stage cement job. Log still required.
0371026182 2012-10-30 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0639378930 2016-12-01 Production Wells No Violations Inspected production well on 12/01/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection.
1000783956 2020-6-17 0:00: PW No Violations
1002133559 2005-02-15 Preliminary Restoration No Violations Meets requirements for Primary Restoration.
1066014601 2016-12-01 Preliminary Restoration No Violations Inspected production well on 12/01/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1100697298 2004-09-23 Preliminary Restoration No Violations Pits closed area graded and seeded.
1363738962 2015-03-12 Production Wells No Violations This production pumping unit well has no evident issues at this time.
1405939775 2004-06-01 Drill / Deepen / Reopen No Violations Capstar Drilling moving in today next to Morton Salt field and advise on problems that may occur when drilling near a solution mine.
1405939775125422 2004-6-1 0:00:0 PW No Violations 1.50
1405939775137131 2004-6-1 0:00:0 DD No Violations 1.50
1408999639 2017-06-14 Preliminary Restoration No Violations Inspected production well on 06/14/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1583989560 2017-06-14 Production Wells No Violations Inspected production well on 06/14/2017. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. No problems were noted at the time of the inspection.
1600100065 2004-06-03 Drill / Deepen / Reopen No Violations Capstar Drilling dusting on 7 7/8 hole at 1540ft. All safety equipment in place.
1680898305 2014-02-21 Production Wells No Violations This is a producing pump jack well with no apparent problems at time of inspection.
1719643241 2016-05-26 Production Wells No Violations Inspected production well on 05/26/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1960928903 2018-06-26 Production Wells No Violations Inspected production well on 06/26/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
371026182 2012-10-30 0:00 PW No Violations

For data sources see[9]