{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.87,"lon":-82,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Chester Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: HOFFMAN INC | |
License Status: Producing | |
License Date: 2004-06-04 | |
Spud Date: 2004-08-31 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2004-09-07 | |
Well Total Depth: 5390.00 ft | |
Configuration: Vertical | |
Latitude: 40.870000 | |
Longitude: -82.000000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2004-06-04 | Proposed Formations:OHIO SHALE-PACKER SHELL; QUEENSTON THRU TREMPEALEAU (MAY NOT PRODUCE CLINTON), Issued Date:6/4/2004, Expired Date:6/4/2005 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-08-31 | RBDMS Rec |
Completed | 2004-09-07 | RBDMS Rec |
Reached Total Depth | 2004-09-07 | RBDMS Rec |
Construction Permit Expires | 2005-06-04 | RBDMS Rec |
Completion Report Received | 2005-10-12 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-12-20 | 5329 | 5342 | 40 |
5329 | 5342 | 40 | |
5329 | 5342 | 40 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1200 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | CGAS EXPLORATION | 730.00 | 0.00 | 365 |
2006 | CGAS EXPLORATION | 1007.00 | 0.00 | 365 |
2007 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 365 |
2008 | ENERVEST OPERATING LLC | 1350.00 | 0.00 | 365 |
2009 | ENERVEST OPERATING LLC | 1722.00 | 0.00 | 365 |
2010 | ENERVEST OPERATING LLC | 889.00 | 0.00 | 365 |
2011 | ENERVEST OPERATING LLC | 220.00 | 0.00 | 0 |
2012 | ENERVEST OPERATING LLC | 622.00 | 0.00 | 366 |
2013 | ENERVEST OPERATING LLC | 862.00 | 0.00 | 365 |
2014 | ENERVEST OPERATING LLC | 606.00 | 0.00 | 365 |
2015 | ENERVEST OPERATING LLC | 296.00 | 0.00 | 193 |
2016 | ENERVEST OPERATING LLC | 310.00 | 0.00 | 185 |
2017 | ENERVEST OPERATING LLC | 285.00 | 0.00 | 189 |
2018 | ENERVEST OPERATING LLC | 259.00 | 0.00 | 202 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | CGAS EXPLORATION | Brine | 0 | 365 |
2006 | CGAS EXPLORATION | Brine | 0 | 365 |
2007 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2008 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2009 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2010 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2011 | ENERVEST OPERATING LLC | Brine | 0 | |
2012 | ENERVEST OPERATING LLC | Brine | 0 | 366 |
2013 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2014 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2015 | ENERVEST OPERATING LLC | Brine | 0 | 193 |
2016 | ENERVEST OPERATING LLC | Brine | 0 | 185 |
2017 | ENERVEST OPERATING LLC | Brine | 0 | 189 |
2018 | ENERVEST OPERATING LLC | Brine | 0 | 202 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1015761663 | 2017-2-1 0:00:0 | PL | No Violations | |
-1106763508 | 2004-9-1 0:00:0 | DD | No Violations | 5.50 |
-112099889 | 2004-9-7 0:00:0 | DD | No Violations | 1.50 |
-1290070172 | 2004-9-11 0:00: | DD | No Violations | 1.00 |
-1364135342 | 2016-10-19 0:00 | PW | No Violations | |
-1422823994 | 2008-3-24 0:00: | PL | No Violations | 1.00 |
-1423495864 | 2016-3-9 0:00:0 | PW | No Violations | |
-1557812992 | 2017-2-1 0:00:0 | PW | No Violations | |
-696011586 | 2018-7-3 0:00:0 | PW | No Violations | |
-87436526 | 2004-9-27 0:00: | PL | No Violations | 1.20 |
0087436526 | 2004-09-27 | Preliminary Restoration | No Violations | Pits being pumped off to close.Area needs graded and seeded. |
0112099889 | 2004-09-07 | Drill / Deepen / Reopen | No Violations | Check on drilling status and found Capstar at 5433ft. Drilling on fluid.All safety equipment in place. |
0354688791 | 2004-08-31 | Drill / Deepen / Reopen | No Violations | Capstar Drilling is at 390 ft. on 11 inch surface hole. |
0693126251 | 2016-10-19 | Preliminary Restoration | No Violations | Inspected production well on 10/19/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0696011586 | 2018-07-03 | Production Wells | No Violations | Inspected production well on 07/03/2018. The well is equipped with a flanged wellhead with 1-master valve, a pressure gauge, elbow, and flowline. Well identification is clearly displayed at the wellhead. No tanks are associated with the well. No problems were noted at the time of the inspection. |
1015761663 | 2017-02-01 | Preliminary Restoration | No Violations | Inspected production well on 02/01/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1106153423 | 2004-08-31 | Drill / Deepen / Reopen | No Violations | Capstar at 320 ft. on 11 inch surface hole.Return Later that night and set 806 ft. of 8 5/8 casing c/w 260 sks. |
1106763508 | 2004-09-01 | Drill / Deepen / Reopen | No Violations | Capstar Drilling set 806 ft. of 85/8 casing c/w 260 sks. |
1247343875 | 2004-09-02 | Drill / Deepen / Reopen | No Violations | Capstar dusting at 2275ft. On 7 7/8 hole. |
1290070172 | 2004-09-11 | Drill / Deepen / Reopen | No Violations | Check on drilling status and found rig has moved and pits are good for level and liners in place.Water truck is hauling fluid off pits today. |
1364135342 | 2016-10-19 | Production Wells | No Violations | Inspected production well on 10/19/2016. The well is equipped with a flanged wellhead with 1-master valve and a flowline. Well identification is posted at the wellhead. No tanks are associated with the well. No problems were noted at the time of the inspection. |
1405603379 | 2014-07-16 | Production Wells | No Violations | Production well with no apparent problems at time of inspection. |
1422823994 | 2008-03-24 | Preliminary Restoration | No Violations | Meets requirements for Primary Restoration. |
1423495864 | 2016-03-09 | Production Wells | No Violations | Inspected production well on 03/09/2016. The well is equipped with a flanged wellhead with 1-master valve and flowlines. Well identification is clearly displayed. No tanks were noted nearby. No problems were noted at the time of the inspection. |
1557812992 | 2017-02-01 | Production Wells | No Violations | Inspected production well on 02/01/2017. The well is equipped with a flanged wellhead with 1-master valve, and a flowline. Well identification is clearly displayed. There are no tanks associated with the well. No problems were noted at the time of the inspection. |
1653823956 | 2020-7-2 0:00:0 | PW | No Violations | |
1870906248 | 2004-09-07 | Drill / Deepen / Reopen | No Violations | Capstar drilling in on fluid at 5433ft. Wait to see if well is dry and found that they will run pipe.All safey equipment was in place during my inspection . |
354688791 | 2004-8-31 0:00: | DD | No Violations | 1.50 |
693126251 | 2016-10-19 0:00 | PL | No Violations |