If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25520 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.79,"lon":-81.85,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: East Union Township | |
Operator Name: KENOIL LLC | |
Well Pad ID: | |
Farm/Lease Name: HODGE DANIEL | |
License Status: Producing | |
License Date: 2007-02-06 | |
Spud Date: 2007-07-15 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-07-20 | |
Well Total Depth: 3800.00 ft | |
Configuration: Vertical | |
Latitude: 40.790000 | |
Longitude: -81.850000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-05-17 | Proposed Formations:CLINTON, Issued Date:5/17/2005, Expired Date:5/17/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2007-02-06 | Proposed Formations:CLINTON, Issued Date:2/6/2007, Expired Date:2/6/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-07-20 | RBDMS Rec |
Reached Total Depth | 2007-07-20 | RBDMS Rec |
Completion Report Received | 2007-12-14 | RBDMS Rec |
Construction Permit Expires | 2008-02-06 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-02-22 | 3640 | 3698 | 0 |
3640 | 3698 | 0 | |
3640 | 3698 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1800 Bbl | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | KENOIL LLC | 0.00 | 72.00 | 0 |
2008 | KENOIL LLC | 614.00 | 1586.00 | 365 |
2009 | KENOIL LLC | 859.00 | 937.00 | 365 |
2010 | KENOIL LLC | 615.00 | 967.00 | 365 |
2011 | KENOIL LLC | 173.00 | 425.00 | 0 |
2012 | KENOIL LLC | 149.00 | 450.00 | 366 |
2013 | KENOIL LLC | 1235.00 | 412.00 | 365 |
2014 | KENOIL LLC | 636.00 | 294.00 | 365 |
2015 | KENOIL LLC | 348.00 | 273.00 | 365 |
2016 | KENOIL LLC | 282.00 | 220.00 | 365 |
2017 | KENOIL LLC | 212.00 | 233.00 | 365 |
2018 | KENOIL LLC | 350.00 | 162.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | KENOIL LLC | Brine | 1110 | |
2008 | KENOIL LLC | Brine | 327 | 365 |
2009 | KENOIL LLC | Brine | 141 | 365 |
2010 | KENOIL LLC | Brine | 125 | 365 |
2011 | KENOIL LLC | Brine | 242 | |
2012 | KENOIL LLC | Brine | 249 | 366 |
2013 | KENOIL LLC | Brine | 171 | 365 |
2014 | KENOIL LLC | Brine | 92 | 365 |
2015 | KENOIL LLC | Brine | 74 | 365 |
2016 | KENOIL LLC | Brine | 64 | 365 |
2017 | KENOIL LLC | Brine | 74 | 365 |
2018 | KENOIL LLC | Brine | 160 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-124617881 | 2017-7-11 0:00: | PL | No Violations | |
-1249640770 | 2017-7-11 0:00: | PW | No Violations | |
-1290415508 | 2020-4-16 0:00: | PW | No Violations | |
-1790911717 | 2016-4-14 0:00: | PW | No Violations | |
-474843223 | 2007-7-23 0:00: | DD | No Violations | 1.00 |
-527696457 | 2015-6-22 0:00: | PW | No Violations | 0.50 |
-790624960 | 2007-7-16 0:00: | DD | No Violations | 4.50 |
-907674968 | 2016-12-2 0:00: | PW | No Violations | |
0124617881 | 2017-07-11 | Preliminary Restoration | No Violations | Inspected production well on 07/11/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0474843223 | 2007-07-23 | Drill / Deepen / Reopen | No Violations | Rig has finished up and the pit level and the liner are good . |
0527696457 | 2015-06-22 | Production Wells | No Violations | Pumping unit well. No apparent problems at this time. |
0550554190 | 2013-07-15 | Production Wells | No Violations | This is a pumping unit well in operation at time of inspection. There appears to be no problems at this time. |
0760424648 | 2018-07-23 | Production Wells | No Violations | Inspected production well on 07/23/2018. The tank battery consists of 1-210 bbl steel tank, 2-100 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; 1-drip is located nearby. The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. The well is located ~140 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Gregg Miller and Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection. |
0790624960 | 2007-07-16 | Drill / Deepen / Reopen | No Violations | Capstar Drilling set 443 ft. of 8 5/8 casing c/w 200 sks - 11 hole to 488 ft. Petroset -Rich |
0907674968 | 2016-12-02 | Production Wells | No Violations | Inspected production well on 12/02/2016. The tank battery consists of 1-210 bbl steel tank, 2-100 bbl steel tanks, and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1188403202 | 2007-07-18 | Drill / Deepen / Reopen | No Violations | Capastar Drilling at 2180 ft. on 7 7/8 hole . |
1249640770 | 2017-07-11 | Production Wells | No Violations | Inspected production well on 07/11/2017. The tank battery consists of 1-210 bbl steel tank, 2-100 bbl steel tanks, 1-vertical separator, 2-drips, and 1-meter box, located within an earthen dike. The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. A small earthen dike is present around the wellhead. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1338568944 | 2012-04-24 | Preliminary Restoration | No Violations | Meets requirements for Preliminary Restoration. |
1403532219 | 2014-06-20 | Production Wells | No Violations | This is a pumping unit well that appears to have no problems at time of inspection. |
1634270714 | 2007-10-17 | Preliminary Restoration | No Violations | Meets requirements for Prilim restoration. |
1790911717 | 2016-04-14 | Production Wells | No Violations | Inspected production well on 04/14/2016. The tank battery consists of 1-210 bbl steel tank, 2-100 bbl steel tanks, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (3), however well identification is only posted for one of the wells. Martha Morris with Kenoil was notified of this issue and will pass it on to the field staff to be addressed. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No other problems were noted at the time of the inspection. |
2124414857 | 2016-12-02 | Preliminary Restoration | No Violations | Inspected production well on 12/02/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
550554190 | 2013-7-15 0:00: | PW | No Violations | 0.50 |
760424648 | 2018-7-23 0:00: | PW | No Violations |
For data sources see[9]