34-169-25602

Well Details

Well ID: 34-169-25602
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: DERBY OPERATING CORP
Well Pad ID:
Farm/Lease Name: VARNS D
License Status: Producing
License Date: 2009-06-11
Spud Date: 2009-07-18
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 2009-07-27
Well Total Depth: 5525.00 ft
Configuration: Vertical
Latitude: 40.830000
Longitude: -81.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-06-03 Proposed Formations:TREMPEALEAU, Issued Date:6/3/2008, Expired Date:6/3/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2009-06-11 Proposed Formations:TREMPEALEAU, Issued Date:6/11/2009, Expired Date:6/11/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-07-27
Completion Report Received 2009-11-16
Construction Permit Expires 2010-06-11
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 DERBY OPERATING CORP 1941.00 592.00 70
2010 DERBY OPERATING CORP 20094.00 5203.00 365
2011 DERBY OPERATING CORP 20764.00 3728.00 365
2012 DERBY OPERATING CORP 12459.00 2753.00 366
2013 DERBY OPERATING CORP 7680.00 1809.00 365
2014 DERBY OPERATING CORP 7333.00 1480.00 365
2015 DERBY OPERATING CORP 4096.00 1180.00 365
2016 DERBY OPERATING CORP 3225.00 872.00 365
2017 DERBY OPERATING CORP 2808.00 736.00 365
2018 DERBY OPERATING CORP 1840.00 695.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 DERBY OPERATING CORP Brine 0 70
2010 DERBY OPERATING CORP Brine 0 365
2011 DERBY OPERATING CORP Brine 0 365
2012 DERBY OPERATING CORP Brine 0 366
2013 DERBY OPERATING CORP Brine 0 365
2014 DERBY OPERATING CORP Brine 0 365
2015 DERBY OPERATING CORP Brine 0 365
2016 DERBY OPERATING CORP Brine 0 365
2017 DERBY OPERATING CORP Brine 0 365
2018 DERBY OPERATING CORP Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1138405289 2018-2-8 0:00:0 PW No Violations
-1195702654 2009-9-14 0:00: PL No Violations 1.00
-1245507525 2010-4-14 0:00: PL No Violations 1.00
-1424529323 2017-1-13 0:00: PL No Violations
-1490565272 2019-7-16 0:00: PW No Violations
-914743565 2020-4-15 0:00: PW No Violations
0917729828 2017-01-13 Production Wells No Violations Inspected production well on 01/13/2017. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank (shared with the Varns #7 well; PN: 169-25601), and 1-vertical separator, located within an earthen dike; the diked area is shared with the tank battery for the Varns #7 well (PN: 169-25601). The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1138405289 2018-02-08 Production Wells No Violations Inspected production well on 02/08/2018. The tank battery consists of 2-210 bbl steel tanks, 1-50 bbl steel tank, 2-vertical separators, 2-drips, and 2-meter boxes, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, located within cattle fencing. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1195702654 2009-09-14 Preliminary Restoration No Violations Restoration is not ready , been too dry
1245507525 2010-04-14 Preliminary Restoration No Violations
1355664007 2014-08-04 Production Wells No Violations This pumping unit well appears to have no problems at this time.
1424529323 2017-01-13 Preliminary Restoration No Violations Inspected production well on 01/13/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
1669139782 2016-04-18 Production Wells No Violations Inspected production well on 04/18/2016. The tank battery consists of 2-210 bbl steel tanks, 1-50 bbl steel tank, and 2-vertical separators located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, located within cattle fencing. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1938098745 2013-07-03 Production Wells No Violations This is a producing pump jack well running at time of inspection. No apparent problems.
2010011570 2009-07-27 Drill / Deepen / Reopen No Violations Maric Drilling is running 4 inch casing and should finish up tonight and move Tues.
917729828 2017-1-13 0:00: PW No Violations

For data sources see[8]