X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-25629

Well Details

Well ID: 34-169-25629
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Wayne Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: STARR FAMILY TRUST
License Status: Producing
License Date: 2008-12-08
Spud Date: 2009-06-25
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2009-07-07
Well Total Depth: 5587.00 ft
Configuration: Vertical
Latitude: 40.860000
Longitude: -81.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-08 Proposed Formations:QUEENSTON THRU TREMPEALEAU (MAY NOT PRODUCE CLINTON), Issued Date:12/8/2008, Expired Date:12/8/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-07-07
Completion Report Received 2009-09-30
Construction Permit Expires 2009-12-08
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-29 5484 5500 33
5484 5500 33
5484 5500 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 648 Bbl 20900

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 ENERVEST OPERATING LLC 9215.00 3447.00 365
2010 ENERVEST OPERATING LLC 16649.00 6045.00 365
2011 ENERVEST OPERATING LLC 11200.00 4174.00 0
2012 ENERVEST OPERATING LLC 5741.00 2069.00 366
2013 ENERVEST OPERATING LLC 4523.00 2372.00 365
2014 ENERVEST OPERATING LLC 3819.00 1760.00 365
2015 ENERVEST OPERATING LLC 2901.00 1015.00 365
2016 ENERVEST OPERATING LLC 2398.00 845.00 366
2017 ENERVEST OPERATING LLC 1722.00 647.00 365
2018 ENERVEST OPERATING LLC 1458.00 481.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 ENERVEST OPERATING LLC Brine 375 365
2010 ENERVEST OPERATING LLC Brine 136 365
2011 ENERVEST OPERATING LLC Brine 330
2012 ENERVEST OPERATING LLC Brine 419 366
2013 ENERVEST OPERATING LLC Brine 73 365
2014 ENERVEST OPERATING LLC Brine 7 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 15 365
2018 ENERVEST OPERATING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1093955768 2017-2-3 0:00:0 PW No Violations
-109746519 2009-6-29 0:00: DD No Violations 1.50
-148896284 2015-12-15 0:00 PW No Violations
-1647739638 2009-6-26 0:00: DD No Violations 1.50
-1771540340 2020-4-9 0:00:0 PW No Violations
-193827493 2013-7-5 0:00:0 PW No Violations 0.50
-1993286773 2018-3-8 0:00:0 PW No Violations
-33214047 2009-7-2 0:00:0 DD No Violations 1.50
-696066135 2017-2-3 0:00:0 PL No Violations
-803827716 2012-4-25 0:00: PW No Violations 1.00
0012005631 2009-06-30 Drill / Deepen / Reopen No Violations Capstar at 3400 ft soaping on 7 7/8 hole with still a odor of H2S
0033214047 2009-07-02 Drill / Deepen / Reopen No Violations Capstar at 4260 ft soaping , did not notice H2S today.
0068067964 2016-10-19 Production Wells No Violations Inspected production well on 10/19/2016. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank (shared with the Starr #1 well, PN: 169-25166), and 1-vertical separator, located within an earthen dike. The diked area is shared with the remaining production equipment for the Starr #1 well. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0109746519 2009-06-29 Drill / Deepen / Reopen No Violations Capstar Drilling is at 2672 ft on 7 7/8 hole- some smell of H2 S
0148896284 2015-12-15 Production Wells No Violations Inspected production well on 12/15/2015. The tank battery consists of 2-210 bbl steel tanks, 1-50 bbl steel tank, and 2-vertical separators located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0193827493 2013-07-05 Production Wells No Violations This pump jack well was in operation at time of inspection and has no apparent problems at this time.
0260962253 2016-10-19 Preliminary Restoration No Violations Inspected production well on 10/19/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0353650141 2009-06-24 Drill / Deepen / Reopen No Violations Rig was to move in today .No rig yet , location is built .GPS reading
0696066135 2017-02-03 Preliminary Restoration No Violations Inspected production well on 02/03/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0803827716 2012-04-25 Production Wells No Violations This well is in operation.
1093955768 2017-02-03 Production Wells No Violations Inspected production well on 02/03/2017. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank (shared with the Starr #1; PN: 169-25166), and 1-vertical separator, located within an earthen dike; the diked area is shared with the tank battery for the Starr #1 well (PN: 169-25166). The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1126667128 2014-10-16 Production Wells No Violations Pumping unit well that appears to have no problems or violations.
12005631 2009-6-30 0:00: DD No Violations 1.50
1263905518 2009-06-23 Drill / Deepen / Reopen No Violations Pit construction on HB 278 well - Met with Vic of Capstar for placement of pits and construction.
1421893454 2009-07-06 Drill / Deepen / Reopen No Violations Capstar is logging - run casing tonight and move Tuesday
1575106481 2010-04-12 Preliminary Restoration No Violations Meets requirements for Primary restoration.
1647739638 2009-06-26 Drill / Deepen / Reopen No Violations Capstar @ 400 ft on 11 surface hole, ready to set in moring.Had to switch over to fluid.
1993286773 2018-03-08 Production Wells No Violations Inspected production well on 03/08/2018. The tank battery consists of 1-210 bbl steel tank, 1-50 bbl steel tank (shared), 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike; the diked area and noted equipment are shared with the Starr #1 well (PN: 169-25166). The well is equipped with a pump jack with an electric motor. The well was pumping at the time of the inspection. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
2055976453 2019-8-6 0:00:0 PW No Violations
260962253 2016-10-19 0:00 PL No Violations
353650141 2009-6-24 0:00: DD No Violations 1.00
68067964 2016-10-19 0:00 PW No Violations

For data sources see[9]

References