34-169-25667

Well Details

Well ID: 34-169-25667
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Canaan Township
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name: RICHARD ALLEN
License Status: Producing
License Date: 2012-05-24
Spud Date: 2012-08-18
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2012-08-24
Well Total Depth: 3381.00 ft
Configuration: Vertical
Latitude: 40.950000
Longitude: -81.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-05-24 Proposed Formations:TREMPEALEAU, Issued Date:5/24/2012, Expired Date:5/24/2014 12:00:00 PM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2012-08-10 CHANGE IN PROPOSED TOTAL DEPTH, PROPOSED GEOLOGICAL FORMATION & CASING PROGRAM. CORRECTION TO X,Y CORRDINATES.
Reached Total Depth 2012-08-24
Completion Report Received 2012-10-10
Construction Permit Expires 2014-05-24
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-10-11 3170 3175 8
2012-10-11 3205 3210 16
3170 3175 8
3205 3210 16
3220 3225 16
3170 3175 8
2012-10-11 3220 3225 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-09-18 H2O 15 98961 Gal 27500 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 MFC DRILLING INC 0.00 0.00 92
2013 MFC DRILLING INC 1265.00 0.00 365
2014 MFC DRILLING INC 2775.00 0.00 365
2015 MFC DRILLING INC 1879.00 0.00 365
2016 MFC DRILLING INC 1667.00 0.00 365
2017 MFC DRILLING INC 1665.00 0.00 365
2018 MFC DRILLING INC 1086.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 MFC DRILLING INC Brine 0 92
2013 MFC DRILLING INC Brine 126 365
2014 MFC DRILLING INC Brine 64 365
2015 MFC DRILLING INC Brine 0 365
2016 MFC DRILLING INC Brine 71 365
2017 MFC DRILLING INC Brine 0 365
2018 MFC DRILLING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1020994164 2015-3-4 0:00:0 PW No Violations 0.50
-1152678211 2012-8-20 0:00: DD No Violations
-1251476219 2012-11-15 0:00 PL No Violations
-1286652756 2017-1-25 0:00: PW No Violations
-1339563292 2014-1-7 0:00:0 PW No Violations 0.50
-1991896618 2012-8-13 0:00: DD No Violations
-2031884077 2016-10-28 0:00 PW No Violations
-2053866182 2012-8-18 0:00: DD No Violations
-2073021891 2017-1-25 0:00: PL No Violations
-489152031 2012-9-19 0:00: DD No Violations
-60353561 2015-11-2 0:00: PW No Violations
-822247656 2016-10-28 0:00 PL No Violations
-861482341 2018-2-27 0:00: PW No Violations
0060353561 2015-11-02 Production Wells No Violations Inspected production well on 11/02/2015. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
0397691460 2012-10-01 Drill / Deepen / Reopen No Violations The well is complete. The pump jack is on location but has not yet been installed. The tank battery has been set. The gas and flow lines have been installed. The well is not yet producing.
0489152031 2012-09-19 Drill / Deepen / Reopen No Violations The well was fractured on 9/18/12. The well was sand pumped and the tubing was run this date. The pits have been closed. There were no problems noted.
0822247656 2016-10-28 Preliminary Restoration No Violations Inspected production well on 10/28/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0861482341 2018-02-27 Production Wells No Violations Inspected production well on 02/27/2018. The tank battery consists of 2-100 bbl steel tanks, 1-vertical separator, 1-drip, and 1-meter box, located within an earthen dike. Well identification is clearly displayed. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1020994164 2015-03-04 Production Wells No Violations This is a pumping unit well. There appears to be no problems at this time.
1152678211 2012-08-20 Drill / Deepen / Reopen No Violations Drilling ahead at 1319, on fluid.
1251476219 2012-11-15 Preliminary Restoration No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection. The location has been put back to grade. It is in cropland and will be planted in the spring.
1286652756 2017-01-25 Production Wells No Violations Inspected production well on 01/25/2017. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
1339563292 2014-01-07 Production Wells No Violations This pumping unit well has no apparent problems at time of inspection.
1482883654 2012-10-10 Drill / Deepen / Reopen No Violations This well is complete. They are setting the pumping unit today. They will hook up the flow and sales lines as well. They are waiting on an electric hook up.
1991896618 2012-08-13 Drill / Deepen / Reopen No Violations No activity on cutting the location.
2031884077 2016-10-28 Production Wells No Violations Inspected production well on 10/28/2016. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator, located within an earthen dike. Well identification is clearly displayed at the tank battery. The well is equipped with a pump jack with an electric motor. No problems were noted at the time of the inspection.
2053866182 2012-08-18 Drill / Deepen / Reopen No Violations Ran 10 joints of 8-5/8 20# casing to 432. Universal cemented with 55 sacks of lite and 65 sacks of regular Class A cement. Good returns. See Casing Ticket for details.
2073021891 2017-01-25 Preliminary Restoration No Violations Inspected production well on 01/25/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes.
397691460 2012-10-1 0:00: DD No Violations
878356402 2020-4-14 0:00: PW No Violations

For data sources see[9]

References