X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-173-61145

Well Details

Well ID: 34-173-61145
Loading map...
Country: United States
State: Ohio
County: Wood
Municipality: Henry Township
Operator Name: UNREGISTERED OWNER
Well Pad ID:
Farm/Lease Name: SMC FOUNDRY
License Status: Final Restoration
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.180000
Longitude: -83.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2006-03-29 INSPECTED BY KEN PIISPANEN ON 2/23/06. THIS WELL IS LOCATED ON A PROPERTY WHOSE OWNERSHIP IS BEING DECIDED IN PROBATE COURT. THE TWO PARTIES INVOLVED, DONNA CARLTON AND JAMES ATKINS'- COMPANY SMC FOUNDRY - USED GAS FROM THE WELL IN THE PAST. GAS FROM THE WELL APPARENTLY WAS ALSO USED TO HEAT THE CARLTON HOME. GAS IS CURRENTLY NOT BEING USED FROM THE WELL. THE WELL IS LEAKING WHICH RESULTED IN GAS AND HYDROGEN SULFIDE BEING RELEASED IN A RESIDENTIAL NEIGHBORHOOD.
Plugged by Orphan Well Program 2006-05-16 Plugged by Orphan Well Program
Plugged/Abandoned 2006-05-16 INSPECTED BY KEN PIISPANEN ON 2/23/06. THIS WELL IS LOCATED ON A PROPERTY WHOSE OWNERSHIP IS BEING DECIDED IN PROBATE COURT. THE TWO PARTIES INVOLVED, DONNA CARLTON AND JAMES ATKINS'- COMPANY SMC FOUNDRY - USED GAS FROM THE WELL IN THE PAST. GAS FROM THE WELL APPARENTLY WAS ALSO USED TO HEAT THE CARLTON HOME. GAS IS CURRENTLY NOT BEING USED FROM THE WELL. THE WELL IS LEAKING WHICH RESULTED IN GAS AND HYDROGEN SULFIDE BEING RELEASED IN A RESIDENTIAL NEIGHBORHOOD.

I&O CN 2006 04 027

Record Last Modified 2013-03-14 INSPECTED BY KEN PIISPANEN ON 2/23/06. THIS WELL IS LOCATED ON A PROPERTY WHOSE OWNERSHIP IS BEING DECIDED IN PROBATE COURT. THE TWO PARTIES INVOLVED, DONNA CARLTON AND JAMES ATKINS'- COMPANY SMC FOUNDRY - USED GAS FROM THE WELL IN THE PAST. GAS FROM THE WELL APPARENTLY WAS ALSO USED TO HEAT THE CARLTON HOME. GAS IS CURRENTLY NOT BEING USED FROM THE WELL. THE WELL IS LEAKING WHICH RESULTED IN GAS AND HYDROGEN SULFIDE BEING RELEASED IN A RESIDENTIAL NEIGHBORHOOD.

I&O CN 2006 04 027

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1654039866 2006-4-17 0:00: PW No Violations
-2087762513 2006-3-28 0:00: PW No Violations
-704718795186131 2006-2-27 0:00: PW No Violations
-719016136186135 2006-2-23 0:00: PW No Violations
1023716391 2006-06-06 Orphan No Violations Well was cut off below ground and hole backfilled. Area was seeded and vegetation is growing. Fence behind carryout has not been replaced. Dave Barndt said that pieces to repair fence were left on site but were gone when he returned to complete the work. New parts will be obtained and fence repaired. Employees at carryout said that respiratory problems and headaches have stopped since well was plugged.
1141059004 2006-02-22 Production Wells No Violations Received phone call from Harry Parsons of 209 East Broadway Street in North Baltimore. Gas well located behind his property was leaking natural gas. A drive thru carryout is located at the above address. Since vehicles turn to enter the drive thru at the back of his property, he was concerned of a chance of fire or explosion. Empolyees at the carryout were also complaining of headaches. Gas was escaping around a cap on the top of the well and made a shrill whistling sound as it escaped. The odor of gas and hydrogen sulfide was evident in the area. Spoke to Donna Carlton who lives on the property where the gas well is located. She indicated that ownership of the property is in probate court. She also indicated that a business adjacent to the property where the wells are located used the natural gas from the wells at one time. The business SMC, located at 100 Peters Street, is an aluminum foundry. Mrs. Carlton gave me the name (James Atkins) and phone number of the owner of the business. A call to Mr. Atkins resulted in a message left on his answering machine. The inspector called the city fire department to make them aware of the situation and to check if a gas detector was available. The fire department did not have a gas meter and the inspectors meter was not functioning properly. Discussed situation with Jeff Fry. Will return in AM to further evaluate the situation.
1141059004186132 2006-2-22 0:00: PW No Violations
1141075332 2006-02-23 Production Wells No Violations Inspection of leaking gas well with supervisor Jeff Fry. Odor of gas and hydrogen sulfide was evident in the area. Check with gas meter resulted in no excessive levels except when placed near the gas escaping at the top of the well. Numerous complaints of odor were received from neighbors in the area. Spoke to Fire Chief, Don Baltz, who released pressure from the well last night due to complaints of shrill whistling resulting from gas escaping from the well. Spoke to James Atkins and Donna Carlton who both admitted that gas from the well was used in the past for operation of an aluminum foundry and home heating. Mrs. Carltons late husband, Franz Carlton, was a 50% partner with Mr. Atkins in the foundry business. The Carlton home located next to the foundry, had utilities including gas, that were connected to the foundry. North Baltimore Village Administrator, Henry DeJulia, also stopped to express his concern for public health and safety due to the leaking gas
1141075332186136 2006-2-23 0:00: PW No Violations
1144845742 2006-03-30 Production Wells No Violations AM inspection. Follow up to inspection on 3/28/06 that well behind carryout was leaking again. No repairs have been made to the well yet. Spoke to Dave Barndt who indicated that he will make repairs today.
1146151523 2006-04-27 Production Wells No Violations Took Right of Entry form to SMC Foundry. Left copy with employee since Mr. Atkins was not available at the time. Requested Mr. Atkins be given Right of Entry form and return to inspector. Also took Right of Entry form to Mrs. Carlton who signed form while on site. Well was leaking gas from the top of the casing at time of inspection and odor was noticable when approaching well. The Division will plug the 3 wells on the property on emergency contract since there is a public health and safety issue.
1146669087 2006-05-03 Production Wells No Violations Well still leaking. Odor of H2S noted around well. Stopped at Mrs. Carltons house to deliver copy of letter from ODNR MRM dated 4/19/06 concerning plugging of well. Nobody was home at the time. During inspection on 4/27/06, discussion with Mrs. Carlton indicated that she did not receive a copy of the letter. Obtained a State of Ohio Orphan Well Program Plugging Application and Right of Entry Release from Mrs. Carlton at that time and explained that the State would plug the 3 oil/gas wells on the properties on an emergency basis and then seek compensation through the probate court from the responsible parties as detailed in the letter.
1146761247 2006-05-04 Production Wells No Violations Spoke to Mrs. Carlton and son Diamond Carlton on site. Delivered copies of letter from ODNR MRM dated 4/19/06 concerning plugging of 3 wells on site. Revised State of Ohio Orphan Well Program Plugging Application and Right of Entry Release obtained from Mrs. Carlton on 4/27/06. Odor of gas from well still evident.
1147718065 2006-05-15 Production Wells No Violations Operator on site to plug well. Well depth is 1260 feet. A 4 inch casing is cemented to a 6 inch casing at the surface. A 10 inch drive pipe was also noted at the surface. There was no fluid in the well casing. Approximately 4-5 yards of 9 sack grout with 2% CaCl was gravity fed into the 4 inch casing. Additional cement will be gravity fed into the well tomorrow to complete the plugging.
1147807696 2006-05-16 Production Wells No Violations Well was cut off 4 feet below ground elevation. A 4 inch and 6 inch casing were noted. There was no cement between the 4 and 6 inch as noted at the surface. Nine sack grout was gravity fed into the 4 and 6 inch casing on top of the approximately 4-5 yards of 9 sack grout poured on 5/15/06. Nine additional yards of cement were gravity fed into the casings before cement level appeared at the surface.Cement levels remained in the top of the casing.
1151341178 2006-06-21 Orphan No Violations Repair to fence behind carryout has not yet been completed. Will talk to operator about when work will be completed.
1153150847 2006-07-13 Final Restoration No Violations Fence has been repaired behind the carryout. Grass is growing on the well site. Spoke to Ben Carlton who was satisfied with the work done. Final restoration will be recommended for approval.
1223787415 2006-03-30 Production Wells No Violations PM inspection. Repairs have been made to the well. No odor of hydrogen sulfide as noted in the morning. Dave Barndt indicated that he was going to install a rubber plug in the casing to try to reduce the gas pressure. A slight hissing sound was evident but no odor. Also noted a pressure gauge on the casing. Employee at carryout said that the volunteer fire department had been at the well site in the afternoon.
1654039866 2006-04-17 Production Wells No Violations Responded to phone message from North Baltimore Village Administrator, Henry DeJulia concerning gas leaking from well located behind the North Baltimore Beverage Center. The odor of hydrogen sulfide was noted as approaching the well. Inspection of the well casing found no hissing gas as noted in previous inspections, in fact there was no odor of gas noted at the wellhead. However, when standing several feet away from the well the odor of hydrogen sulfide was evident. It is possible that gas is leaking from the casing below ground. Spoke to Jeff Fry, Mrs. Carlton and Bill at carryout during inspection.
2087762513 2006-03-28 Production Wells No Violations Received phone call from Bill at carryout to report that well behind business is leaking again. The odor of hydrogen sulfide was evident at the well and gas could be heard leaking from the top of the well in the same place as before. Spoke to Mrs. Carlton while on site to inform her of the problem. Gave her phone number for Dave Barndt who repaired the well on 2/24/06. Inspector also called Dave Barndt at time of inspection to inform him of the problem. Contacted village administrator Henry DeJulia to let him know well was leaking again.
7047187951 2006-02-27 Production Wells No Violations Follow up to complaint on 2/22/06. There was no gas leaking from the well at time of inspection nor was there any odor of gas in the area. Repairs to well made by Dave Barndt on 2/23/06 were not successful so he returned the next day (2/24/06) to make additional repairs. Noted that gas supply pipe from well that went into ground had been removed. Discussion with employees at carryout located next to the well indicated that there has been no further escape of gas since repairs were completed on 2/24/06. Followed up on several complaints from neighbors concerned about health and safety from gas leak. Conditions appear to have returned to those prior to leak.
7190161361 2006-02-23 Production Wells No Violations The well is located on property whose ownership is currently being decided in probate court. The 2 parties involved, Donna Carlton and James Atkins whose company, SMC, an aluminum foundry, used gas from the well in the past. Gas from the well apparently was also used to heat the Carlton home. The well is not permitted or bonded with the State of Ohio. According to both parties noted above, gas in not currently being used from the well. This well developed a leak which resulted in gas and hydrogen sulfide being released in a residential neighborhood. Enforcement action will be taken after further discussion with the Columbus office.

For data sources see[3]

References