X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-003-01259

Well Details

Well ID: 37-003-01259
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Kennedy Township
Operator Name: UNKNOWN OPR
Well Pad ID:
Farm/Lease Name: BRIGHTWOOD
License Status: Abandoned
Spud Date:
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.494139
Longitude: -80.108139

For data sources see[1][2][3]

Well History

Date Event
OLD WELL
1901-01-01 Drilling Completion

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2095890 Primary Facility 2012-08-21 Plugging(Includes Plugged/Mined Through) No Violations Noted WELL IS ON THE ABANDONED LIST. HOME OWNERS ACCROSS THE STREET FROM THE WELL ARE CONCERNED ABOUT GAS ODORS. PLUGGING INSPECTOR HAS BEEN UPDATED.
2099812 Primary Facility 2012-09-05 Plugging(Includes Plugged/Mined Through) No Violations Noted FIRE AND GAS CO.S TO ODOR COMPLAINT. NO GAS LINES NEAR THE SITE. THERE WERE NO INCREASE IN ODORS BUT WELL IS STILL LEAKING. THE WELL NEEDS A PROPER VENT.
2428451 Primary Facility 2015-11-30 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Wellhead consists of 6" casing, 3 1/2" casing, 1 1/2" tubing with rods and pumpjack. No tank on site. Well is leaking small amount of gas at casinghead and tubinghead. Hydrocarbon will be rigging up later today or tomorrow to begin plugging.
2428796 Primary Facility 2015-12-01 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon got rig spotted over wellhead, removed pumpjack to prepare to pull rods & tubing.
2429389 Primary Facility 2015-12-02 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon pulling 1 1/2" tubing after getting rods pulled.
2429593 Primary Facility 2015-12-03 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule TIMCO wireline ran Caliper/CCl log. Found TD @ 2121 feet , bottom of 3" casing w/ packer @ 1870 feet. Cut 3" casing above packer @ 1795 feet.
2432086 Primary Facility 2015-12-07 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon ran cement string to 2120 feet, will spot cement plug back to 1800 feet.
2432088 Primary Facility 2015-12-08 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon got all 3" casing pulled, ran cement string and set plug @ 1799 (calculated). TIMCO ran wireline & shot 5 1/2" casing collars @ 1695 feet, 1595 feet and 1486 feet, but casing would not come free. Will continue uphole, cutting collars and attempting to pull.
2432090 Primary Facility 2015-12-09 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon pulling 5 1/2" casing after cutting @ 900 feet.
2432717 Primary Facility 2015-12-14 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon WOC after spotting plug from 898 feet to 458 feet.
2432950 Primary Facility 2015-12-15 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon preparing to spot final plug from top of last plug (538 feet) to surface.
2433805 Primary Facility 2015-12-16 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon plugged well to surface, set monument (no ID plate yet), graded location.
2434572 Primary Facility 2015-12-21 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule Hydrocarbon seeded and mulched location.
2483549 Primary Facility 2016-05-13 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Visited site to check for identification plate, not installed yet. Informed Hydrocarbon.
2483556 Primary Facility 2016-05-04 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Visited site to see if Hydrocarbon had installed the ID plate on the monument pipe; not yet.
2495554 Primary Facility 2016-05-31 Plugging(Includes Plugged/Mined Through) No Adverse Event or Action Reported Visited site to see if Hydrocarbon had installed the ID plate on the monument pipe; not yet. Contacted Hydrocarbon.
2511869 Primary Facility 2016-07-12 Routine/Partial Inspection No Adverse Event or Action Reported Hydrocarbon still needs to attach well marker plate on monument pipe.
2773910 Primary Facility 2018-08-31 Routine/Partial Inspection No Viols - Permanently Shut Down Checked this plugged well to see if an ID plate had been attached after marker was set. I still needs ID plate.

For data sources see[5]

References