X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-003-22455

Well Details

Well ID: 37-003-22455
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Avalon Borough
Operator Name: UNKNOWN OPR
Well Pad ID:
Farm/Lease Name: SPRUCE RUN
License Status: Plugged and Abandoned
Spud Date:
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Undetermined
Conservation: No
Latitude: 40.505194
Longitude: -80.073306

For data sources see[1][2][3]

Well History

Date Event
2017-05-01 Begin Plugging
2017-07-06 Finished Plugging
2019-06-26 Fully Plugged

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2602637 Primary Facility 2017-03-31 Follow-up Inspection No Violations Noted Followup to yesterday's DEP response to stray gas reported by Columbia Gas at residence, 343 Spruce Run Road, Pittsburgh (Avalon). Columbia currently purging the soil of gas, using test holes in yard near the high gas readings they found in basement wall and porch floor cracks. A 2 3/8" tubing against house next to high readings can be seen venting a significant amount of gas. Digging was done at the base of the vent pipe, revealing an elbow and lateral pipe leading away from house into yard. Test results of gas indicate it is not pipeline gas.
2602642 Primary Facility 2017-04-04 Follow-up Inspection No Violations Noted DEP representatives on site to meet w/ representative from Allegheny Well Service to propose how to proceed with an evaluation of the vent and how to excavate to locate the source of the stray gas/vent gas. Got consent form signed by property owner. Ran DEP metal detector, found possible source near house, but a lot of stray readings.
2602653 Primary Facility 2017-04-10 Plugging(Includes Plugged/Mined Through) In Compliance with Schedule A state emergency contract was issued to evaluate this site for remediation or plugging. The evaluation phase of the contract given to Allegheny Well Service, who subcontracted an excavation operator to dig around the vent. The vent was found to lead a few feet from the house, then lead down ~5 feet into the bottom of an overturned bucket set on top of a steel barrel. When the barrel was excavated and removed, a "cellar" about 2' in diameter, ~ 2' deep was found below the barrel with 2 3/8" tubing centered in it. It was partly filled w/ water and gas was bubbling up through the water. The tubing was not gassing. A measuring rod was lowered into cellar and went down ~12 feet before encountering obstruction. Area around well was excavated ~ 8' deep & supported.
2602658 Primary Facility 2017-04-11 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Allegheny ran a wireline into the tubing, hit a solid obstruction @ 815 feet. They pumped the water out of the well cellar to a depth of 5-6 feet. the cellar had some debris, including bottles, metal and some rocks, but was basically open. No wellhead or casing was found.
2602670 Primary Facility 2017-04-14 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T Service & Supply visited site to evaluate for plugging proposal & estimate. (Allegheny provided a plugging proposal & estimate also) Met w/ property owner to discuss possible course of action.
2602683 Primary Facility 2017-04-27 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T vacuumed out the well cellar, redressed threads on tubing and screwed on a new collar. Tried to set 20 feet of 8" casing, but after meeting some resistance when tapped, the casing slipped down and out of sight into annulus area. Then 15" conductor was carefully set & driven into place.
2602702 Primary Facility 2017-05-01 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Visited site before S&T rig mobilization. Hole was completely backfilled, replacing all of the excavated soil & rig pads were placed. Rig on site by mid morning. Ran ~600 feet of 1" tubing into 2 3/8" by 2:30 PM. Shut down for an hour due to heavy rains/storms. Tried to start back up but storms shut down operations again for the rest of the day. Borough of Avalon Public Works Supervisor visited location @ 11:30 AM to check on plugging operations.
2602839 Primary Facility 2017-05-02 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T power swiveled/cleaned out wood obstruction from 830-835 feet. Penetration rate slowed considerably, so pulled string to check bit (bit is 1" collar dressed w/ carbide).
2602840 Primary Facility 2017-05-04 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Rich Freese & I discussed progress of cleanout so far w/ S&T. Current depth is 838 feet. They appear to be drilling on something hard w/ 1" bit, so they plan to fabricate 1 1/2" collar w/carbide to possibly go over obstruction. Well has gassed occasionally through tubing. Well is not taking fluid.
2602841 Primary Facility 2017-05-09 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T TIH w/ new 1 1/2" bit & barrel w/2 grabs. Got hold of fish but lost. TOOH, cut 3 more grabs in barrel, TIH. Current depth is 875 feet.
2602842 Primary Facility 2017-05-11 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T TOOH w/ barrel, got pieces of rope in bit. Rigged up rod socket & TIH. Current depth is 898 feet.
2602843 Primary Facility 2017-05-12 Plugging(Includes Plugged/Mined Through) In Compliance with Policy No activity @ site today. Checked well for flowback-gassing into tank.
2602844 Primary Facility 2017-05-16 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T power swiveling to 880'-890', TOOH to check for rope fillup. They are getting some circulation back up the tubing. As they drill & fish out rope, they lose depth in tubing to rope rising.
2602845 Primary Facility 2017-05-17 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T went in hole w/ rod socket & retrieved pieces of rope. TIH w/ bit to continue to drill/clean out rope, lost ~20 depth to rope rising in tubing. Still gassing through tubing.
2602847 Primary Facility 2017-05-22 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Ran DEP camera in tubing to 700 feet-rope fillup. Ran camera into annulus, got to ~ 60 feet. Could see tubing and possibly the 8" casing that dropped, but visibility was poor. S&T TIH w/ spear.
2602850 Primary Facility 2017-05-26 Plugging(Includes Plugged/Mined Through) In Compliance with Policy No activity @ site, so check well for flowback status. Annulus has plastic vent re-installed, extending to roofline. No detectable gas flow from tubing to tank or up ventpipe.
2602855 Primary Facility 2017-05-30 Plugging(Includes Plugged/Mined Through) In Compliance with Policy No activity at site, shut down for holiday. Check flowback status. All well, w/ no noticeable gas/fluid flow from tubing to tank.
2602861 Primary Facility 2017-06-01 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Shut down for holiday, no activity. Well is quiet, w/ no noticeable gas/fluid flow.
2602862 Primary Facility 2017-06-05 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Checked site (prior to S&T arrival mid morning). No gas/fluid flowback noted.
2602864 Primary Facility 2017-06-05 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T fishing w/ rod socket on tubing, got ~1 foot of rope. Will TIH using sand line & newly fabricated fishing tools.
2602865 Primary Facility 2017-06-06 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T cleaned out to tubing to 1120 feet late yesterday, pulled out a single length of rope 155 feet long. Fishing efforts today have pulled the rope up to 1070 feet. They used a center spear most of the morning, pulling out chunks of rope each trip. Appeared to grab entire fish 2-3 times, moved uphole some, but could not pull out.
2602867 Primary Facility 2017-06-06 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T fishing w/ rod socket on 1" tubing.
2602869 Primary Facility 2017-06-08 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T TIH w/ spear/overshot on tubing, drove ~5 feet, then TOOH, got nothing. Depth: 1200'
2602870 Primary Facility 2017-06-08 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T fishing w/ center spear on sand line, getting chunks of rope.
2608099 Primary Facility 2017-06-13 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T pulled ~8 feet of rope yesterday. Today @ 1235 feet. TIH w/10 foot center spear on work string, TOOH w/ nothing, Put spear on tool string w/ jars on sand line, TIH, snagged some rope, stalled rig pulling, but only got rope chunks. Repeated. Well is gassing today after being dead for several days.
2608105 Primary Facility 2017-06-14 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T @ 1245 feet. TIH w/ rod socket on tubing. TOOH w/ pieces of rope. TIH w/ center spear on tubing.
2608112 Primary Facility 2017-06-15 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T TIH w/ center spear on tubing, got small pieces of rope. Repeated, pulled weight to 490 feet, then broke free. Went in w/ center spear on sand line, pulled fish to 290 feet then broke free, but pulled out ~4 feet of rope. Repeated, pulled out 6 feet of rope, followed by a strong blow of gas. TIH w/ center spear on sandline, back to bottom.
2608117 Primary Facility 2017-06-15 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T fishing w/ center spear on sandline, pulled out ~5 foot section of rope from 1279 feet.
2608121 Primary Facility 2017-06-19 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Surefire Wireline logged well: GR, CCL & CBL. Logger TD:1281'. Appears to be tight spots in annulus @ 240', 316', 358', 505' and possibly 670'-712'. Ratty tubing w/ possible holes @~900'.
2608123 Primary Facility 2017-06-21 Plugging(Includes Plugged/Mined Through) In Compliance with Policy No activity @ site today. Work to resume tomorrow. Well is quiet, w/ no gas or water flowback.
2608126 Primary Facility 2017-06-22 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Surefire cut the 2 3/8" tubing @ 1280'. S&T TIH w/ wireline, tagged obstruction @ 1281', TOOH. TIH w/ 1" tubing w/ angled end, bumped @1281', then continued downhole in annulus to 1390', hit bottom or cavings. (This will be attainable bottom.)
2612818 Primary Facility 2017-06-26 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T pumped an 8 sack bottom-hole plug. TOOH w/all 1"work string. Did repairs to damage on yard from logging truck.
2612819 Primary Facility 2017-06-27 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T tagged bottom-hole plug TOC @ 1340 feet. Loggers will perf tomorrow.
2612821 Primary Facility 2017-06-28 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Surefire perfed 2 3/8" tubing from ~1200' to ~900', 2 shots every 50'. S&T TIH w/ tools on sandline to check hole - all clear to top of plug @ 1340', TOOH. TIH w 1" work string to 1336', could not break circulation, pulled tubing up, then able to break circulation. Pumped a 60 sack plug, w/ a calculated top of 960', based on estimated volume of annulus. Pulled workstring up to 762', circulated bottoms up w/ no cement in returns. TOOH w/ remaining 762' of 1".
2612822 Primary Facility 2017-06-29 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T TIH w/ work string, tagged TOC @ 784'. Well no longer gases after setting this last plug. Will perf & pump next plug tomorrow.
2612865 Primary Facility 2017-07-07 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T has moved rig off location and parked it across the street. They will be doing final work on wellhead and restoring yard next week. Columbia Gas is on site to turn gas back on & take gas readings. They will give their go-ahead to have electric turned back on. Homeowner is on site also.
2614010 Primary Facility 2017-07-10 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Rig has been removed from across the street, and one of two tanks has been removed from location. No activity on site at time of inspection.
2614045 Primary Facility 2017-07-10 Plugging(Includes Plugged/Mined Through) In Compliance with Policy S&T on site mid-morning w/ gravel (for the well conductor) & topsoil for the yard. They cut the conductor off ~2' below grade (~6" below window well), filled several feet w/ gravel and filled to top w/ cement and attached well ID tag. They returned the cement-slab step that was moved for plugging operations, then applied & leveled top soil, seeded & mulched.
2614837 Primary Facility 2017-07-12 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Checked site restoration work after recent heavy rains. No ponding or washouts noted. Mulch remained in place.
2615260 Primary Facility 2017-05-10 Drilling/Alteration No Violations Noted S&T RETRIEVED SOME TYPE OF PACKER ASSEMBLY. WE ARE NOT SURE WHAT IT WAS USED FOR. S&T WENT BACK INTO THE TUBING WITH A SMALL BIT TO TRY AND VERIFY TD. THEY PULLED THE BIT AND WITH IT THEY FOUND PIECES OF STEEL AND ROPE.
2615273 Primary Facility 2017-05-11 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T IS MAKING MULTIPLE RUNS INTO THE WELL TO DETERMIN TD. THE LAST FEW RUNS, WIT A ROD SOCKET, THEY HAVE BEEN PULLING OUT PIECES OF ROPE.
2615276 Primary Facility 2017-05-23 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T IS FISHING ROPE SECTIONS FROM THE 2" TUBING. THEY ARE USING WIRELINE AND 1" PIPE TO RUN THIER FISHING TOOLS. THE DEPTH AT 3 PM IS 945'.
2615365 Primary Facility 2017-06-30 Plugging(Includes Plugged/Mined Through) No Violations Noted SUREFIRE WIRELINE IS ON THE SITE TO CUT THE 2" TUBING AT 750' THEN PERF THIER WAY OUT OF THE TUBING.
2615582 Primary Facility 2017-05-09 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T, FISHING INSIDE 2" TUBING CAME OUT EMPTY. THEY RAN ANOTHER SOCKET AND HOOKED ONTO SOMETHING BUT LOST IT COMING OUT OF THE HOLE. AT 2:30 THEY BEGAN ANOTHER RUN.
2615605 Primary Facility 2017-05-08 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T RAN A NEW ROD SOCKET INTO THE TUBING. THE OBSTRUCTION DROPPED 35' TO A DEPTH OF 875'. GAS AND SOME FLUID CAME OUT OF THE 1" WORK STRING.
2615619 Primary Facility 2017-05-22 Plugging(Includes Plugged/Mined Through) No Violations Noted THE DEP RAN A CAMERA INSIDE OF THE 2" TUBING, BUT WAS NOT ABLE TO ADVANCE TO THE BOTTOM OF THE HOLE. THE CAMERA WAS RUN OUTSIDE THE OF THE TUBING AND GOT TO 58'. NO CASING WAS EVIDENT.
2615626 Primary Facility 2017-05-02 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T DRILLED WITH A CARBIDE SHOE, AND RETRIEVED SPLINTERD WOOD AND PART OR A ROD STRAP. THEY ADAPTED A ROD SOCKET TO 1" PIPE AND RAN IN TO FISH. THE FIRST RUN WAS NOT SUCCESSFUL.
2618689 Primary Facility 2017-07-25 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Visited site to check restoration after recent rains. The grass is growing in nicely with no signs of erosion or uneven settling. The straw mulch remains in place.
2624375 Primary Facility 2017-08-07 Plugging(Includes Plugged/Mined Through) In Compliance with Policy Reclamation of site looks good; grass is filling in & soil settling has been minimal.
2652911 Primary Facility 2017-09-19 Site Restoration In Compliance with Policy Visited site to check on grass growth. Generally looking good, with some thin spots.

For data sources see[5]

References