Well Details

Well ID: 37-005-30046
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Kiskiminetas Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: MORGAN NT137
License Status: ACTIVE
Spud Date: 2008-10-23
Permit Date: 2008-10-06
Well Type: COALBED METHANE
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.554743
Longitude: -79.436549

For data sources see[1][2][3]

Well History

Date Event
2008-10-06 New Permit Application
2008-10-22 Performed Spud Operation
2008-10-25 Drilling Completion
2008-11-04 Perforation
2009-03-25 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2009 CNX GAS CO LLC 10068.24 318 0.00 0 0.00 0
2010 CNX GAS CO LLC 26,679.86 365 0.00 0 0.00 0
2011 CNX GAS CO LLC 21,376.55 365 0.00 0 0.00 0
2012 CNX GAS CO LLC 13,351.00 366 0.00 0 0.00 0
2013 CNX GAS CO LLC 10,724.67 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 9,967.36 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 10,492.69 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 9,182.85 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 7,728.09 365 0.00 0 0.00 0
2018 CNX GAS CO LLC 5,888.07 365 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 6,720.00 273 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CNX GAS CO LLC Brine 7,924.57 Bbl Brine or Industrial Waste Treatment Plt PA0091472
2010 CNX GAS CO LLC Produced Fluid 1,311.00 Bbl IDENTIFY METHOD IN COMMENTS PA0253588
2010 CNX GAS CO LLC Produced Fluid 240.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 CNX GAS CO LLC Produced Fluid 51.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2011 CNX GAS CO LLC Produced Fluid 883.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CNX GAS CO LLC Produced Fluid 37.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2011 CNX GAS CO LLC Produced Fluid 16.00 Bbl INJECTION DISPOSAL WELL 34-133-22523
2011 CNX GAS CO LLC Produced Fluid 76.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 CNX GAS CO LLC Produced Fluid 145.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2012 CNX GAS CO LLC Produced Fluid 1,181.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CNX GAS CO LLC Produced Fluid 993.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 CNX GAS CO LLC Produced Fluid 336.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 CNX GAS CO LLC Produced Fluid 2,680.40 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CNX GAS CO LLC Produced Fluid 325 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 CNX GAS CO LLC Produced Fluid 97,975.16 Bbl CENT WASTE TRT FAC NPDES PA0253588
2015 CNX GAS CO LLC Produced Fluid 97,975.16 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0253588
2015 CNX GAS CO LLC Produced Fluid 325.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2015 CNX GAS CO LLC Produced Fluid 1,453.37 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CNX GAS CO LLC Produced Fluid 40.00 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1746323 Primary Facility 2008-10-28 Drilling/Alteration No Violations Noted drilled, pit e/s ok
1848317 Primary Facility 2009-12-04 Site Restoration No Violations Noted Drilling had been completed on on 10/25/08. Well appeared to be equipped for & in production at the time of the inspection. Pumpjack apparatus located onsite and no fluid discharges were observed. In addition three brine tanks were located onsite and appeared to be in sound condition. Well-site had been regraded, and the vegetative cover met the 70% uniform coverage criteria.
2622332 Primary Facility 2017-08-04 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Two brine tanks were located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the access road.

For data sources see[7]