X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-30877

Well Details

Well ID: 37-005-30877
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Gilpin Township
Operator Name: MDS ENERGY DEV LLC
Well Pad ID:
Farm/Lease Name: ROBERT D FRANK JR 1-1
License Status:
Spud Date:
Permit Date: 2011-09-12
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.674908
Longitude: -79.588964

For data sources see[1][2][3]

Well History

Date Event
2011-09-12 New Permit Application
2012-09-05 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 MDS ENERGY LTD 0.00 0 0.00 0 0.00 0
2012 MDS ENERGY LTD 589.00 12 0.00 0 0.00 0
2013 MDS ENERGY LTD 10,808.00 256 0.00 0 0.00 0
2014 MDS ENERGY LTD 6,589.00 337 0.00 0 0.00 0
2015 MDS ENERGY DEV LLC 6,683.00 363 0.00 0 0.00 0
2016 MDS ENERGY DEV LLC 5,448.00 354 0.00 0 0.00 0
2017 MDS ENERGY DEV LLC 5,652.00 365 0.00 0 0.00 0
2018 MDS ENERGY DEV LLC 4,867.00 358 0.00 0 0.00 0
2019 MDS ENERGY DEV LLC 4,607.00 363 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 MDS ENERGY LTD Fracing Fluid Waste 975.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1997971 Primary Facility 2011-08-23 Routine/Complete Inspection No Violations Noted 200' building inspection
2097738 Primary Facility 2012-08-30 Routine/Complete Inspection No Violations Noted Site construction had been completed. Site construction and E&S controls had been implemented as outlined in the approved E&S plan. All disturbed areas not stabilized with rock had been temporarily stabilized with seed & mulch. Entire access road and well pad had been rocked as outlined in the E&S plan. The operator should closely monitor the site and E&S controls to insure the site remains stable until well development activities are completed.
2101351 Primary Facility 2012-09-19 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well site was in the process of being set up for well stimulation. All access road and site erosion controls had functioned properly during the precipitation on 09/18/12 and there was no evidence of accelerated erosion or sedimentation observed in relation to the access road or well-site.
2103402 Primary Facility 2012-09-28 Complaint Inspection No Violations Noted Drilling had been completed and a service rig was located onsite monitoring flowback operations. The frac impoundment and two baker tanks were located onsite. All erosion controls appeared to have been maintained and were functioning properly. There was no observed evidence of accelerated erosion or sedimentation in relation to the access road or well-site. There was evidence observed of sediment transport and deposit on the vegetation in the neighboring yards both abovestream and downstream the well-site indicating that the sediment transport and deposit was part of the normal runoff flow for the area. According to an onsite conversation with MDS personnel the well-site is to be reclaimed within the next 7-10 days.
2108275 Primary Facility 2012-10-17 Routine/Complete Inspection No Violations Noted Drilling had been completed, above grade frac impoundment was in the process of being emptied. Site was being prepped for for final grading and plumbing the well for production. It was noted that th esilt fencing located onsite will be replaced with silt sox until final restoration is completed.
2248997 Primary Facility 2014-02-26 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been restored and the vegetative cover met the 70% uniform coverage criteria.
2644503 Primary Facility 2017-10-06 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.