X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-31109

Well Details

Well ID: 37-005-31109
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Plumcreek Township
Operator Name: EQT PROD CO
Well Pad ID: 145134
Farm/Lease Name: GIRTY 591635
License Status:
Spud Date:
Permit Date: 2012-12-05
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.687378
Longitude: -79.366286

For data sources see[1][2][3]

Well History

Date Event
2012-12-05 New Permit Application
2013-02-05 Performed Spud Operation
2013-03-22 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-06-06 2014-03-04 7,306 12,597,100 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP Breaker Halliburton Breaker Sodium Persulfate 7775-27-1 100 0.00405998 4799.68
BE-9 Halliburton Biocide Tributyl Tetradecyl Phosphonium Chloride 81741-28-8 10 0.00455298 5382.49
Water Halliburton Carrier/Base Fluid Water 7732-18-5 100 88.9223 105,123,000.0
WG-36 Gelling Agent Halliburton Gel Guar Gum 9000-30-0 100 0.230134 272062
LP-65 Halliburton Scale inhibitor Ammonium Chloride 12125-02-9 10 0.00370569 4380.83
Hydrochloric Acid (15%) Halliburton Acidizing Hydrochloric Acid 7647-01-0 15 0.0456129 53923.1
Sand (Proppant) Halliburton Proppant Silica Substrate 14808-60-7 100 10.2885 12,163,000.0
FR-66 Halliburton Friction reducer Hydrotreated Petroleum Distillate 64742-47-8 30 0.0504921 59691.4

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 1,092,053.00 302 0.00 0 0.00 0
2015 EQT PROD CO 732,934.00 365 0.00 0 0.00 0
2016 EQT PROD CO 544,776.00 366 0.00 0 0.00 0
2017 EQT PROD CO 445,954.00 365 0.00 0 0.00 0
2018 EQT PROD CO 368,579.00 361 0.00 0 0.00 0
2019 EQT PROD CO 324,633.00 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 EQT PROD CO Drilling Fluid Waste 480.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Fracing Fluid Waste 1,030.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EQT PROD CO Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 EQT PROD CO Produced Fluid 47,942.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Produced Fluid 353.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014 EQT PROD CO Produced Fluid 310.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014 EQT PROD CO Produced Fluid 206.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014 EQT PROD CO Produced Fluid 512.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2014 EQT PROD CO Produced Fluid 7,266.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2014 EQT PROD CO Produced Fluid 103.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2014 EQT PROD CO Produced Fluid 1,029.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 EQT PROD CO Produced Fluid 203.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-099-2-1956
2014 EQT PROD CO Produced Fluid 111.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2015 EQT PROD CO Produced Fluid 303.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2015 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-167-29395
2015 EQT PROD CO Produced Fluid 316.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2015 EQT PROD CO Produced Fluid 216.00 Bbl INJECTION DISPOSAL WELL 34-155-24076
2015 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2015 EQT PROD CO Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2015 EQT PROD CO Produced Fluid 814.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 EQT PROD CO Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 EQT PROD CO Produced Fluid 858.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2015 EQT PROD CO Produced Fluid 281.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 EQT PROD CO Produced Fluid 1,563.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2015 EQT PROD CO Produced Fluid 693.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2015 EQT PROD CO Produced Fluid 281.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2015 EQT PROD CO Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 EQT PROD CO Produced Fluid 25,059.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 16,980.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016 EQT PROD CO Produced Fluid 1,674.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 260.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 2,241.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EQT PROD CO Produced Fluid 345.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Produced Fluid 1,999.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO Other Oil & Gas Wastes 318.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 3,847.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO 2,982.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO 700.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO 1,779.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EQT PROD CO 345.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Produced Fluid 1,550.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 1,167.51 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 1,475.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 3,054.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 EQT PROD CO Produced Fluid 189.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 EQT PROD CO Produced Fluid 206.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 217.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 23.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EQT PROD CO Produced Fluid 93.46 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 65.00 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 2,009.49 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 298.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EQT PROD CO Produced Fluid 136.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 27.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2132930 Primary Facility 2013-01-24 Routine/Complete Inspection No Violations Noted Met with operator representative Bruce Gallick onsite. Site construction was underway. All perimeter and access road eorsion controls had been implemented as outlined in the Girty Project ESCGP (ESX12-005-0015). There were no observed accelerated erosion or sedimentation issues observed in relation to the site or access road.
2140178 Primary Facility 2013-02-08 Drilling/Alteration No Violations Noted Conductor set
2140253 Primary Facility 2013-02-14 Drilling/Alteration No Violations Noted Conductor set
2146780 Primary Facility 2013-02-26 Drilling/Alteration No Violations Noted WOC @ 885'
2150768 Primary Facility 2013-03-12 Drilling/Alteration No Violations Noted moving rig off location
2159280 Primary Facility 2013-04-16 Drilling/Alteration No Violations Noted at 8800'
2164892 Primary Facility 2013-04-24 Drilling/Alteration No Violations Noted production casing installed and cemented
2179814 Primary Facility 2013-07-01 Routine/Complete Inspection No Violations Noted Well development activities were onogin on the well-pad at the time of the inspection. Site containment was in place and appeared to be in sound condition. Eight Baker tanks were located onsite and all eight were located on containment. Both the (as labeled) Reserve pit and the Freshwater Impoundment contained fluids and had more than two feet of lined freeboard. Site and access road erosion controls appeared to be functioning properly, properly maintained and there was no observed evidence of accelerated erosion or sedimentation in relation to the site or access road. All soil stockpiles and slopes had been temporarily stabilized with vegetation.
2200256 Primary Facility 2013-08-30 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was not equipped for production. Site containment was still ocated onsite, however no well development equipment was located onsite. Both the (as labeled) Reserve and Freshwater Impoundment contained fluids and had more than two feet of lined freeboard. Site and access road erosion controls appeared to be functioning properly, properly maintained and there was no observed evidence of accelerated erosion or sedimentation in relation to the site or access road. All soil stockpiles and slopes had been temporarily stabilized with vegetation.
2211837 Primary Facility 2013-10-09 Routine/Complete Inspection No Violations Noted Drilling had been completed, well was in the process of being equipped for production. Both the (as labeled) Reserve and the Freshwater Impoundments contained fluids and had more than two feet of lined freeboard. Site and access road erosion controls appeared to be functioning properly, properly maintained and there was no observed evidence of accelerated erosion or sedimentation in relation to the site or access road. All soil stockpiles and slopes had been temporarily stabilized with vegetation.
2225603 Primary Facility 2013-11-27 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater and flowback impoundments located onsite and both had more than two feet of freeboard. There was no accelerated erosion or sedimentation observed in relation to the site. Site and access road erosion controls appeared to have been maintained and were functioning as intended.
2250969 Primary Facility 2014-03-05 Complaint Inspection No Violations Noted 3 wells drilled and being equipped.
2258802 Primary Facility 2014-04-01 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater and flowback impoundments located onsite and both had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2290461 Primary Facility 2014-07-25 Routine/Complete Inspection No Violations Noted operating ; ID OK
2291249 Primary Facility 2014-07-29 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater and flowback impoundments located onsite and both had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2295451 Primary Facility 2014-08-12 Complaint Inspection No Violations Noted 3 wells drilled and equipped. 1 conductor set. 3 tanks and 1 roll-off onsite.
2296968 Primary Facility 2014-08-05 Routine/Complete Inspection No Violations Noted operating ID OK
2304361 Primary Facility 2014-09-05 Routine/Complete Inspection No Violations Noted operating: under Alpha Hunter rig
2313399 Primary Facility 2014-10-16 Routine/Complete Inspection No Violations Noted Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater and flowback impoundments located onsite and both had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2313989 Primary Facility 2014-10-21 Complaint Inspection No Violations Noted Frac underway.
2330949 Primary Facility 2014-12-19 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater and flowback impoundments located onsite and both had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2353748 Primary Facility 2015-03-10 Complaint Inspection No Violations Noted operating ID OK Prod Presssure = 406 psig
2359998 Primary Facility 2015-04-09 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road.
2404174 Primary Facility 2015-09-01 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All implemented site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road.
2435452 Primary Facility 2015-12-23 Routine/Complete Inspection No Violations Noted Well tagged-in production. Equipment-tanks-dike-E&S controls-well site look good.
2546434 Primary Facility 2016-12-15 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All implemented site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Site had been regraded to meet the PCSM drawing and it had been temporarily stabilized with mulch, the vegetation had not germinated and had subsequently not reached 70% uniform vegetative cover.
2587884 Primary Facility 2017-04-27 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite within secondary containment. Brine tank appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2617147 Primary Facility 2017-07-20 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Site had been effectively restored. The majority of the site had attained 70% uniform perennial vegetation and the remainder has been returned to agricultural activities by the landowner.
2627352 Primary Facility 2017-08-18 Routine/Complete Inspection No Violations Noted system running. no issues
2636295 Primary Facility 2017-09-15 Routine/Complete Inspection No Violations Noted
2664953 Primary Facility 2017-11-29 Routine/Complete Inspection No Violations Noted Multi-well pad. At time of inspection, well drilled and appears equipped for production. The three other wells on this pad are also drilled and appear equipped for production.
2788663 Primary Facility 2018-10-15 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2821715 Primary Facility 2019-01-03 Routine/Complete Inspection No Violations Noted This well is tagged and in production with the annulus open. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[8]

References