Well History

Date Event
2011-05-18 New Permit Application
2011-05-21 Performed Spud Operation
2011-11-14 Perforation
2012-04-19 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-15 2011-12-15 6,158 4,429,866

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Superior Well Services Propping Agent
Quartz 14808-60-7 99.90 23.16
KR-153SL Superior Well Services Biocide Polyethylene glycol 25322-68-3 5000.00
Ethylene glycol 107-21-1 100.00
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.03
Diethylene glycol 111-46-6
Super Scale Control TSC Superior Well Services Scale Inhibitor
Anionic Copolymer
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
Anionic Polymer
1,2-Propylene glycol 57-55-6 0.02
Water Base Fluid Fresh Water 100.00 76.66
WFR-3B Superior Well Services Friction Reducer Stoddard solvent 8052-41-3 10.00
Ethoxylated C12-16 alcohols 68551-12-2 4.00
1,2-Propylene glycol 57-55-6 25.00
Distillates, petroleum, hydrotreated light 64742-47-8 0.11

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,791,611.33 304 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,013,674.00 361 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 887,491.00 294 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 809,092.51 310 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,091,417.36 358 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 819,367.04 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 680,372.02 356 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 899,643.05 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Drill Cuttings 1,102.65 Tons LANDFILL 301626
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 65.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 157.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 2,460.30 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 594.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 577.55 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 179.80 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 279.16 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 2.26 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 55.34 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 18.38 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 69.32 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1981671 Primary Facility 2011-06-16 Drilling/Alteration No Violations Noted Rig Manager - Patterson 251. Walk around site all OK. 3H completed. Currently spudding 4H with Koder
1990558 Primary Facility 2011-07-25 Routine/Complete Inspection No Violations Noted Conductor and surface casing cut off. No visible bubbling. 0 psi on 9 5/8. No gauge on 13 3/8. Vented to tank.
2051589 Primary Facility 2012-03-14 Routine/Complete Inspection No Violations Noted An incident occured at the site. Was contacted by Ralph Larsen of Chief at 10:15AM. Travelled to site w/ Kevin Costello, and Eric Rooney. When we arrived on site we were informed that the situation had been handled. The company Man on site was Bill Burton, and the Safety Manager was Allicia Cook. Accident occured between 9 & 9:30AM. While cleaning upplastic containment, Site Safe operator hooked on to line at wellhead and broke off 1/2" methanol injection line & pressure guage(see photos). Everyone evacuated site including people in house above site. EMS, Wild Well, CUDD as well as appropiate DEP personel were contacted. Wysox FD and Cudd responded. FD provided fresh water spray and Cudd person shut gate valve on B section of well head to stop flow of gas at about 12 noon. There was no fire or fluids. Gas was flowing out of 1/2" line for about 2 1/2 hrs. Pressure and vol. of gas are unknown. When DEP personel arrived, FD was gone and CUDD was leaving. DEP ER John Erich and Dennis Wolfe also responded. Left site at about 2PM.
2103169 Primary Facility 2012-09-12 Routine/Complete Inspection No Violations Noted Well is producing, 1929 psi.
2298711 Primary Facility 2014-08-11 Routine/Complete Inspection No Violations Noted
2306435 Primary Facility 2014-09-19 Routine/Complete Inspection No Violations Noted While in the process of surveying the site, I observed an area of standing water on the pad surface behind the reuse water tank battery. There was also an area of standing water inside the tank battery. The water inside the tank battery appeared to be sediment laden. It had a rust like appearance to it; orange and brown in color. Based on visual observance of the discolored water in containment and water on the pad surface which appeared to be emanating from under the containment system, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen the water for conductivity. Conductivity readings were in the range of (6-8) milliSiemens/cm in containment. I recorded over the limit conductivity readings on the pad surface just outside containment and in standing water pooled in rocks in the site perimeter ditch. The highest possible recorded reading on this meter is (19.99) milliSiemens/cm.
2308786 Primary Facility 2014-09-26 Follow-up Inspection No Violations Noted I met with (2) employees of Mr. Dirt, the company Chief Oil and Gas has subcontracted to remediate an area of staining and potential contamination of the NW corner of the pad surface. Thus far Mr. Dirt has filled (7) steel containers of excavated material in the general area where I recorded elevated conductivity readings in surface water next to the reuse water and gas buster tank battery. Please see the 9/19/14 inspection report, which describes the details of the conditions observed at the site and the conductivity readings recorded on my meter. The remediation of the pad surface was temporarily halted as Mr. Dirt was waiting for another container as they have planned to continue to excavate the impacted area. The 8th container as part of the remediation process is expected to be the final container as part of the process, according to Mr. Dirt. Mr. Dirt stated that around (250) cubic yards of the pad surface has been excavated and filled into containers up to this point.
2440939 Primary Facility 2016-01-14 Routine/Complete Inspection No Violations Noted
2508231 Primary Facility 2016-08-04 Routine/Complete Inspection No Violations Noted
2518847 Primary Facility 2016-09-13 Site Restoration No Violations Noted
2642792 Primary Facility 2017-10-02 Routine/Complete Inspection No Violations Noted Four wells staged for production. Site has interim restoration. Four separators within containment. One production tank severely corroded. The operator will empty the 1H tank by the afternoon of 10/2/2017. No violations noted at this time.
2803104 Primary Facility 2018-11-13 Routine/Complete Inspection No Violations Noted This site was restored and the NOT was acknowledged 8/8/16.

Four wells are staged for production. Four GPUs are present within secondary containment. This containment was in good condition overall. One steel produced water tank is present and in good condition. The secondary containment around the produced water tank is steel with plastic lining and is in good condition.

A labeled methanol container is present near the well heads. This container sits on top of a black plastic tank. The department recommends more substantial secondary containment for this container. An unlabeled green container is also present near the well heads. The department recommends labeling this container.

Several portions of the pad which had been restored and vegetated have been disturbed by truck traffic. In these areas, the soil has been compacted, some vegetated has died, and water is ponding. The department recommends restabilizing these areas as needed in the spring.

Post Construction Stormwater Management (PCSM) is handle