37-015-22120

Well Details

Well ID: 37-015-22120
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Windham Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149211
Farm/Lease Name: ROGERS 05 235 03 H 3H
License Status:
Spud Date:
Permit Date: 2012-02-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.987283
Longitude: -76.313036

For data sources see[1][2][3]

Well History

Date Event
2012-02-16 New Permit Application
2012-07-11 Performed Spud Operation
2013-03-13 Perforation
2014-02-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-03-12 2013-03-12 4,850 5,731,488

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer Water Water 7732-18-5 100.0 85.36187
FEAC-20 Trican Iron Control Citric acid 77-92-9 30.0 0.00025
Acetic acid 64-19-7 45.0 0.00038
BioClear 5000 Trican Biocide Polyethylene glycol 25322-68-3 70.0 0.01874
2,2-dibromo-3-nitrilopropionamide 10222-01-2 10.0 0.00268
HCl 7.5 Trican Acid Hydrochloric acid 7647-01-0 7.5 0.00463
WG-111L Trican Gelling Agent polysaccharide blend 9000-30-0 60.0 0.00306
light hydrotreated petroleum distillate 64742-47-8 60.0 0.00306
Frac Sand - regular Trican Proppant Crystalline silica 14808-60-7 100.0 14.39482
AI-7NR Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1.0 None
HCl 3.5 Trican Acid Hydrochloric acid 7647-01-0 3.5 0.00209
GBO-1 Trican Breaker Sodium perBorate tetrahydrate 10486-00-7 100.0 0.00025
LSI-21 Trican Scale Inhibitor Sodium Salt of Phosphate Ester 68131-72-6 15.0 0.0038
Acrylic Polymer 28205-96-1 15.0 0.0038
FR-8 Trican Friction Reducer Petroleum distillates, dewaxed heavy paraffinic 64742-65-0 8.0 0.00506
Petroleum distillates, hydrotreated heavy paraffinic 64742-54-7 8.0 0.00506
Petroleum distillate hydrotreated light 64742-47-8 28.0 0.01772
Ammonium chloride 12125-02-9 1.5 0.00095

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 974,777.10 316 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 742,488.60 362 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 606,064.80 364 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 483,371.70 365 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 399,791.30 365 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 347,266.30 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 REPSOL OIL & GAS USA LLC Drill Cuttings 1,272.62 Tons LANDFILL 8-0728-0004/013
2012 REPSOL OIL & GAS USA LLC Drill Cuttings 75.79 Tons LANDFILL NY31346244
2013 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 22.09 Tons LANDFILL 100361
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 1,355.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 REPSOL OIL & GAS USA LLC Produced Fluid 6,371.93 Bbl REUSE OTHER THAN ROAD SPREADING
2015 REPSOL OIL & GAS USA LLC Produced Fluid 715.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 820.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 REPSOL OIL & GAS USA LLC Produced Fluid 205.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 865.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 REPSOL OIL & GAS USA LLC Produced Fluid 410.00 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 410.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 410.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2117649 Primary Facility 2012-08-15 Routine/Complete Inspection No Violations Noted Well drilled, mouse hole covered with 2X4. Well shut-in. No gauges on annuli. Contact rep concerning mousehole.
2156126 Primary Facility 2013-04-11 Routine/Complete Inspection No Violations Noted
2249185 Primary Facility 2014-02-25 Routine/Complete Inspection No Violations Noted
2351150 Primary Facility 2014-11-10 Routine/Complete Inspection No Violations Noted No gauges on annuli. Well in production. Cellar filled with water, no visible bubbling.
2352393 Primary Facility 2014-11-10 Routine/Complete Inspection No Violations Noted 3 wells on pad. Unable to determine if the conductor was set on wells 1H and 2H as cellar was covered with cement and manhole. Rogers 3 well was in production, however no gauges on any of the annuli. Cellar filled with water, with no visible bubbling.
2465417 Primary Facility 2016-03-16 Routine/Complete Inspection No Violations Noted
2627754 Primary Facility 2017-08-16 Routine/Complete Inspection No Violations Noted On August 16, 2017, the Department conducted a routine inspection at the Repsol Oil and Gas USA LLC, Rogers H (05-235) well site in Windham Township, Bradford County. Andrew Hobbins, Water Quality Specialist represented the Department. Nobody was present for Repsol.

The site sign, E & S plan and weekly inspection logs were on site and available for review. No erosion or sedimentation issues were observed. PCSM has been addressed at the site.

One well was in production during the inspection. The well was labeled and no bubbling was observed in the well cellar. On GPU and One production tank were in secondary containment. Liquid within the containment was low in specific conductivity. Puddles on the pad were also low in specific conductivity. No staining was observed.

Two infiltration basins were installed at the site to address PCSM. The well pad has not been reduced in size. A two year restoration extension was approved by the Department on 12/2/2016. No violations were observed during the

2810389 Primary Facility 2018-12-04 Site Restoration No Violations Noted NOT approval.

Electrical conductivity readings taken from pooled water with an Oakton PCSTestr 35. A puddle on the pad surface near the production tanks is 0.06 mS/cm. JLP