X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-23381

Well Details

Well ID: 37-015-23381
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Stevens Township
Operator Name: SWN PROD CO LLC
Well Pad ID:
Farm/Lease Name: SEYMOUR 5H
License Status:
Spud Date:
Permit Date: 2017-12-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.790364
Longitude: -76.129175

For data sources see[1][2][3]

Well History

Date Event
2017-12-15 New Permit Application
2019-01-04 Permit Renewal Application

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2675747 Primary Facility 2017-12-27 Routine/Complete Inspection No Violations Noted On December 27, 2017, the Department conducted a routine inspection at the SWN Production Company LLC GU-X-Seymour-Pad in Stevens Township, Bradford County. Andrew Hobbins represented the Department. Nobody was present for SWN.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The site has perennial vegetation starting to grow, but does not yet meet the 70% requirement. PCSM has been addressed with the recent installation of two infiltration berms. The berms and surrounding disturbed earth were temporarily stabilized with mulch and erosion control matting.

The 1H and 3H wells were in production during the inspection. Both wells were labeled. The 2H and 4H wells had conductor casing set, but were not drilled to total depth. Liner and rig mats were installed around the well heads. One production tank and two GPUs were observed in secondary containment. Stormwater within the containment structures was observed to be frozen. All puddles on the pad were f

2700484 Primary Facility 2018-02-20 Incident- Response to Accident or Event No Violations Noted On February 20, 2018, the Department conducted an incident response inspection at the SWN Production Company LLC, GU-X-Seymour-Pad in Stevens Township, Bradford County. Andrew Hobbins, Water Quality Specialist, and Jon Sassi, Environmental Protection Specialist, represented the Department. Tommy Howard, well site supervisor, and Tracy Gregory, Regulatory Analyst, were on site for SWN. The Department was notified by Steve Moyer on February 18, 2018 that approximately 130 gallons of diesel spilled onto containment. A tear was found in the liner and diesel made its way under the liner and onto the surface of the pad. Mr. Moyer also noted that SWN had contracted Environmental Resource Recovery to remediate the spill.

The Department arrived on site at 1030 hrs. and observed 6 roll-off containers staged on secondary containment. Five containers contained contaminated soil, and one container was filled with liner material. The Department then observed the site of the spill. The excavation area was covere

2718014 Primary Facility 2018-04-13 Follow-up Inspection No Violations Noted Site being prepped for stimulation activities. Felt backed 30 mil liner being installed at his time. Water storage tank on location. No spills detected. Site stable. Residual clean-up operation remain for spilled diesel from February 2018 (insp 2696952). No issues detected.

For data sources see[5]

References