37-019-00637

Well Details

Well ID: 37-019-00637
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Washington Township
Operator Name: KING HARRY L
Well Pad ID:
Farm/Lease Name: BURNS 5
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.056639
Longitude: -79.8335

For data sources see[1][2][3]

Well History

Date Event
1890-01-01 Drilling Completion
1986-01-01 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1990 KING HARRY L 0.00 0 261.33 365 0.00 0
1991 KING HARRY L 0.00 0 218.00 365 0.00 0
1992 KING HARRY L 0.00 0 161.50 365 0.00 0
1993 KING HARRY L 0.00 0 129.33 365 0.00 0
1994 KING HARRY L 0.00 0 80.00 365 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
212104 Primary Facility 1990-02-26 Routine/Complete Inspection No Violations Noted
2661492 Primary Facility 2017-11-09 Routine/Partial Inspection No Violations Noted At the time of inspection, unable to determine if well has produced within the year. I did not see a sheen on the rods. There were 2 tanks within an earthen dike. A 100 bbl steel tank and a 50 bbl poly tank. A separator was made up and hooked up to the steel tank. The tanks sounded empty. A small pump jack is hooked up to electric. I did not see a label on the well and production has not been reported to the Department since 1993.
2763535 Primary Facility 2018-08-09 Routine/Partial Inspection Violation(s) Noted At the time of inspection, well does not appear to have produced within the past year. A phone call was received concerning the well and would like something done with the well. They stated that the well is a liability in its current condition. The well was inspected in 2017 and the inspection stated that I was unable to determine if it had produced. During todays inspection, it was noticed that the pump jack was in the exact position it was a year ago.

The well was equipped with 2" tubing inside of 4" casing. There was also 6 1/4" surface casing and wooden conductor. Electricity is hooked up to the well, but not sure if it is active. It did not appear as though the well was hooked up to produce gas so the well appears to be abandoned. There was a slight hint of gas in the air.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2763535 825215 2018-08-09 OGA3220(A) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
825215 367235 NOV - Notice of Violation

For data sources see[6]

References