Well History

Date Event
2015-03-09 New Permit Application

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 NTS ENERGY LLC 0.00 0 0.00 0 0.00 0
2016 NTS ENERGY LLC 930.00 120 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 NTS ENERGY LLC Produced Fluid 50.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2365536 Primary Facility 2015-04-28 Drilling/Alteration No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 40 ft. and was sanded in. 9 5/8” pipe was set at 399 feet. On 4/28/15, cement of pipe was completed with 135 sks of Type I and 8 bbl. return. C&J Energy performed cement project. Water was recorded at 290 feet and coal was recorded at 63 ft. Current depth was 430 feet.
2365568 Primary Facility 2015-04-28 Complaint Inspection No Violations Noted DEP personnel, Paul Wyrwas and Jason Brannon inspected complaint of water notice. DEP met property owner. Complainant was not home. Property owner was concern that drilling adjacent to his property will affect his potable water source and was not notified of drilling. As per regulation, all property owners with potable wells were sampled and notified of drilling activity. Currently, the property owner resident home and adjacent trailer were approximately 2500 feet from gas well. DEP and owner walked to resident’s water source to take a GPS reading. Based on location on directions of owner, a location of N 40^ 37.673’ and W 78^45.207’ was recorded at point source. Based on this location, the source was 1900 feet from the gas well. Property was also recorded several ponds and springs on property located on the hillside of the resident with water flow to the pond and surface stream located on the hillside.
2365575 Primary Facility 2015-04-29 Routine/Complete Inspection No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 40 ft. and was sanded in. 9 5/8” pipe was set at 399 feet. 7” pipe was set at 910 feet. On 4/29/15, cement of pipe was completed with 180 sks of Class AI and 6 bbl. return. C&J Energy performed cement project. Water was recorded at 290 feet and coal was recorded at 63 ft. Current depth was 940 feet. Plug was down at 11:58 hrs. Anticipated depth is 3900 feet.
2368368 Primary Facility 2015-04-29 Routine/Complete Inspection Violation(s) Noted On-site inspection in response to spud notification for 4/27/2015.At time of inspection, drill rig on-site. Site ID sign present. Valid drilling permit posted. E&S plan on-site.Per on-site plan, Operator representative made “field changes” to E&S plan previously prepared by certified engineer. Changes include the addition of access road culverts, substitution of BMPs, the location of the access road, and potentially the location of the wellhead.Beginning of shared access road rocked and in good condition.Beginning of access road has been re-located per changes made to the E&S plan by Operator representative.Culverts not identified on the E&S plan have been installed in several locations along the access road and are not equipped with adequate outlet protection.Silt fence with hay bales have been installed in place of compost sock as identified on the E&S plan. Silt fence is not properly installed and/or maintained.**ADDITIONAL COMMENTS ON PAPER SAIR**
2368606 Primary Facility 2015-05-05 Drilling/Alteration No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 46 ft. and was sanded in. 13 3/8” pipe was set at 107 feet. A void was encountered at 56 feet approximately 2’. Cement of pipe was completed with 75 sks of Class A and 0 bbl. return. Cement was completed to surface. C&J Energy performed cement project. Current depth was 120 feet. Plug was down at 8:30 hrs. Anticipated depth is 3900 feet.
2368607 Primary Facility 2015-05-06 Drilling/Alteration No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted Whipstock to complete the gas well. Conductor pipe (20”) was set at 46 ft. and was sanded in. 13 3/8” pipe was set at 107 feet. 7” pipe was set at 910’. Cement of pipe was completed with 150 sks of Class A and 3 bbl. return. C&J Energy performed cement project. Current depth was 922 feet. Plug was down at 13:45 hrs. Anticipated depth is 3900 feet.
2371778 Primary Facility 2015-05-11 Routine/Partial Inspection Violation(s) & Outstanding Violations RTPT inspt conducted as follow-up to inspection record 2368368 in which Operator representative Steve Phillips moved the location of the drilled well on the E&S plan from the permitted well location identified on the E&S plan by a certified engineer.
2376835 Primary Facility 2015-06-01 Follow-up Inspection Outstanding Violations - No Viols Req'd On-site FUI conducted in response to viols issued under inspection record 2368368 (enf ID 323048).At time of inspt, well drilled, but not yet equipped for production.Viols previously issued under inspection record 2371778 (enf ID 323515) remain outstanding.Previously requested seasonal high groundwater table data (inspection record 2368368) not yet received by Dept.AR culverts remain un-equipped with adequate outlet protection.One lined below-grade drill pit on-site. Pit remains structurally compromised.The on-site Control and Disposal Plan remains unidentified, inadequate, and continues to be non-compliant with current regulations.Requested written responses to vios issued under inspt records 2368368, 2371778 not yet received by Dept.Viols issued under inspt records 2368368, 2371778 (enf IDs 323048, 323515) remain outstanding.Environ'l Trainee C. Witham present during inspt.**Add'l comments on paper SAIR**
2376955 Primary Facility 2015-05-26 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspt. Department contacted Operator representative Steve Phillips via phone to discuss violations issued under under inspection record 2371778 (enf ID 323515) for failure to drill the well in the exact location as identified on the permitted well plat.
2392134 Primary Facility 2015-07-23 Follow-up Inspection Outstanding Violations - No Viols Req'd On-site FUI conducted in response to violations issued under inspection record 2368368 (enf ID 323048).ARculverts remain un-equipped with adequate outlet protection.Silt fence remains improperly installed and/or maintained.Unidentified earth disturbance down-gradient of perimeter BMPs and disturbed perimeters of well pad nearing 70% uniform and adequate vegetative growth.One lined below-grade drill pit remains on-site. Pit remains structurally compromised with liner closest to wellhead beginning to fall in. Orange security fence around pit is structurally compromised.On-site C&D Plan remains unidentified and inadequate and continues to be non-compliant with current regs.Previously requested seasonal high groundwater table data (inspection record 2368368) not received by the Dept. Requested written responses to viols not received by the Dept.Viols remain outstanding.
2395775 Primary Facility 2015-07-29 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspection conducted in response to violations issued under inspection record 2371778 (enf ID 323515) for failure to drill the well in the exact location as identified on the permitted well plat.
2468380 Primary Facility 2016-03-23 Routine/Complete Inspection No Violations Noted gas well in production. no issues.
2500751 Primary Facility 2016-07-12 Routine/Complete Inspection No Violations Noted system running. no issues
2532283 Primary Facility 2016-10-17 Routine/Complete Inspection No Violations Noted system running. noi issues
2603815 Primary Facility 2017-06-01 Routine/Complete Inspection No Violations Noted system running. no issues
2678236 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted System running no issues. Well tag present. Emergency contact sign present.
2713044 Primary Facility 2018-04-02 Routine/Complete Inspection No Violations Noted Well tag and emergency contact number present at the site. No issues at the site

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2368368 722249 04/29/2015 2015-04-29 102.4(b)1 - EROSION AND SEDIMENT CONTROL REQUIREMENTS - Person conducting earth disturbance activity failed to implement and maintain E & S BMPs to minimize the potential for accelerated erosion and sedimentation. Environmental Health & Safety
2368368 722250 04/29/2015 2015-04-29 78.56(a)4ii - PITS AND TANKS FOR TEMPORARY CONTAINMENT - Failure to construct the pit liner subbase that is smooth, uniform and free from debris, rock and other material that may puncture, tear, cut or otherwise cause the liner to fail. Environmental Health & Safety
2371778 723530 05/11/2015 2015-05-11 OGA3211(F1) - WELL PERMITS - DRILLING - Failure to notify DEP or surface landowner or local political subdivision 24 hours prior to commencement of drilling. Failure to electronically notify DEP. Failure to re-notify DEP. Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
722249 323048 NOV - Notice of Violation Comply/Closed 2016-03-26
722250 323048 NOV - Notice of Violation Comply/Closed 2016-03-26
723530 323515 NOV - Notice of Violation Comply/Closed 2018-02-06

For data sources see[7]