Well Details

Well ID: 37-021-21207
Loading map...
Country: United States
State: Pennsylvania
County: Cambria
Municipality: West Carroll Township
Operator Name: SLA EXPLORATION LLC
Well Pad ID: 152835
Farm/Lease Name: FORD NTS-FORD-2
License Status:
Spud Date:
Permit Date: 2015-08-12
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.627919
Longitude: -78.748939

For data sources see[1][2][3]

Well History

Date Event
2015-08-12 New Permit Application
2015-08-17 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 NTS ENERGY LLC 304.00 30 0.00 0 0.00 0
2016 NTS ENERGY LLC 0.00 0 0.00 0 0.00 0
2019 HIGHPOINTE OIL & GAS LLC 349.90 245 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 NTS ENERGY LLC Fracing Fluid Waste 285.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2015 NTS ENERGY LLC Fracing Fluid Waste 285 Bbl CENT WASTE TRT FAC NPDES PA0095273
2018 SLA EXPLORATION LLC Produced Fluid 240.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2432136 Primary Facility 2015-12-11 Administrative/File Review In Compliance with Policy This well was originally drilled under permit number 021-21205; however, it was determined to not be drilled in the permitted location (inspection ID 2371778). As a result, violations were issued. To address this violation by the Operator, a new permit was submitted, reviewed, and issued for this well (permit number 021-21207; inspection ID 2395775).
2472759 Primary Facility 2016-03-25 Follow-up Inspection Violation(s) & Outstanding Violations FUI to Insp #2368368:vios issued for failure to implement E&S plan, failure to implement & maintain BMP’s, failure to properly design Control & Disposal plan, failure to properly construct a pit, WT present but not consistant with permit # in Depart records.Site ID sign & E&S plan on site. Control & Disposal plan unidentified & inadequate.Shared AR rocked. Culvert pipe farthest from well becoming filled with sediment/debris, appears unmaintained. Culvert pipe closest to well appears to have improperly installed outlet. Former location of drill pit backfilled. Temp BMP’s down gradient of WH appear improperly installed. Uninstalled silt fence remain on site.Vio issued for failure to properly construct a pit has been corrected. Previously issued vios for failure to implement E&S plan, failure to implement/maintain BMP’s, failure to properly design a Control & Disposal plan remain outstanding.WT improperly labeled with incorrect permit # therefore, vio being issued for failure to install the permit number on com
2535144 Primary Facility 2016-11-08 Follow-up Inspection Outstanding Violations - No Viols Req'd Follow up inspection to Inspection Record #2472759 where violation issued for failure to install permit number on completed well and inspection record #2368368 where violations issued for failure to implement E&S plan, failure to implement and maintain BMP’s, and for failure to properly design a Control and Disposal plan.

At time of inspection well appears equipped for production. Well tag present but not consistant with permit number in Department records. As per inspection record #2395775, the permit number currently on the well head has been canceled. Operator submitted an application for a new well (NTS Ford 2) on 6-17-15 and this permit number (021-21207) should be the number on the well head. Brine tank appears structurally sound. Site ID sign, well permit, and E&S plan on site. Department unable to locate Control and Disposal plan. Shared access road rocked. Culvert pipe farthest from well pad remains filled with sediment/debris and appears unmaintained. Department recommends Operator continue to mon

2656941 Primary Facility 2017-11-01 Follow-up Inspection Violation(s) & Outstanding Violations This well was originally issued permit number 021-21205 but the well was drilled in the wrong location. This well was issued another permit number, 021-21207, that corresponds with the coordinates of the well location.

Follow up inspection to inspection record #2472759 and #2368368. Due to this well being issued a new permit number, this follow up inspection also encompasses inspection record #2368368 and #2371778. Well appears equipped for production. Previously issued violations against both permit numbers remain outstanding. Violation being issued for failure to submit Well Site Restoration Report. A follow up inspection will be conducted at a later date.

2665928 Primary Facility 2017-11-20 Administrative/File Review In Compliance with Policy ADMIN inspection to inspection record #2656941.

Above mentioned inspection returned to Department by USPS as 'not deliverable as addressed'. Inspection re-mailed to Home, PA address. Department recommends operator update records to reflect current address. Violation issued for failure to place permit number on a completed well and for failure to submit well site restoration report remain outstanding. Operator has until 12-18-17 to respond to the NOV issued on 11-1-17.

2689104 Primary Facility 2018-01-29 Administrative/File Review Outstanding Violations - Viols Req'd ADMIN Inspection to inspection record #2472759. Department received Well Site Restoration Report via email from operator rep Steve Phillips. This Restoration Report is administratively incomplete. Department recommends operator resubmit Restoration Report.

Previously issued violations still exist for failure to install well tag (well tag is incorrect) and failure to submit a Well Site Restoration Report. Previously issued violations for failure to maintain BMP's (inspection ID #2368368) and failure to drill well in permitted location (inspection ID #2371778) issued against permit #021-21205 remain outstanding.

2691518 Primary Facility 2018-02-06 Compliance Evaluation No Violations Noted CEI to inspection records #2368368, 2371778, 2472759, and 2656941. Department received well site restoration report from NTS Energy LLC via email. NTS Energy has transferred this well to another operator. NTS Energy LLC has notified the new operator of the incorrect permit number on well head and of failure to implement/maintain BMP's.

Previously issued violation issued under inspection record #2371778 for failure to drill well in exact location on well plat has been corrected due to issuance of new permit number. Previously issued violation under inspection record #2368368 for inadequate control and disposal plan has been corrected. Previously issued violations under above inspections for for failure to submit well site restoration report, failure to place well tag on completed well, and failure to implement/maintain BMP's, have been corrected and closed. NTS Energy LLC appears to be in compliance at this time. A follow up inspection will be conducted at a later date to ensure current operator remains in

2721941 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted Revised Well tag present. Well was in production. Emergency contact numbers present.
2730948 Primary Facility 2018-05-17 Routine/Complete Inspection No Violations Noted Revised Well tag present. Well was in production. Emergency contact numbers present.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2472759 756486 2016-03-25 2016-03-25 OGA3211(H) Administrative
2656941 801165 2017-11-01 2018-02-06 OGA3211(H) Administrative Violation issued 3-25-16. This violation remains outstanding.
2656941 801166 2017-11-01 2017-11-01 78.65(3) Administrative .
2689104 807300 2016-03-25 2018-02-06 OGA3211(H) Administrative
2689104 807301 2017-11-01 2018-02-06 78.65(3) Administrative .

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
756486 341672 NOV - Notice of Violation 2016-03-25

For data sources see[7]

References