X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-027-21660

Well Details

Well ID: 37-027-21660
Loading map...
Country: United States
State: Pennsylvania
County: Centre
Municipality: Snow Shoe Township
Operator Name: XPR RESOURCES LLC
Well Pad ID: 149180
Farm/Lease Name: RESOURCE RECOVERY 3 1H
License Status:
Spud Date:
Permit Date: 2010-12-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.020464
Longitude: -78.056647

For data sources see[1][2][3]

Well History

Date Event
2010-12-14 New Permit Application
2011-02-14 Performed Spud Operation
2011-05-19 Drilling Completion
2011-08-22 Perforation
2012-07-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-08-27 2011-08-27 8,530 3,899,773

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BE-9M Halliburton Energy Services Biocide Methanol 67-56-1 30.00 0.00700000
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00230000
WG-36 Gelling Agent Halliburton Energy Services Gel
Guar gum 9000-30-0 100.00 0.00180000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00090000
Water ARM Group Carrier/Base Fluid Water 100.00 86.20
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.09
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00330000
GBW-30 Breaker Halliburton Energy Services Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00010000
Carbohydrates 95.00 0.00080000
BA-40L Halliburton Energy Services Buffer Carbonic acid, dipotassium salt 584-08-7 60.00 0.01
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 13.64

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 309,127.00 102 0.00 0 0.00 0
2012 XPR RESOURCES LLC 488,412.61 364 0.00 0 0.00 0
2013 XPR RESOURCES LLC 290,932.00 365 0.00 0 0.00 0
2014 XPR RESOURCES LLC 219,463.93 365 0.00 0 0.00 0
2015 XPR RESOURCES LLC 194,631.27 365 0.00 0 0.00 0
2016 XPR RESOURCES LLC 164,597.00 366 0.00 0 0.00 0
2017 XPR RESOURCES LLC 138,002.16 364 0.00 0 0.00 0
2018 XPR RESOURCES LLC 136,092.00 365 0.00 0 0.00 0
2019 XPR RESOURCES LLC 81,430.00 284 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XPR RESOURCES LLC Drilling Fluid Waste 1,155.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 XPR RESOURCES LLC Drill Cuttings 605.00 Tons LANDFILL 100419
2011 XPR RESOURCES LLC Drilling Fluid Waste 780.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 XPR RESOURCES LLC Drilling Fluid Waste 2,140.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011 XPR RESOURCES LLC Fracing Fluid Waste 238.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 XPR RESOURCES LLC Fracing Fluid Waste 716.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2011 XPR RESOURCES LLC Produced Fluid 190.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 XPR RESOURCES LLC Produced Fluid 432.70 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 XPR RESOURCES LLC Produced Fluid 10,633.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 3,717.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014 XPR RESOURCES LLC Fracing Fluid Waste 3,300.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XPR RESOURCES LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 1,320.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XPR RESOURCES LLC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2015 XPR RESOURCES LLC Produced Fluid 302.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 275.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 234.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 XPR RESOURCES LLC Waste comment only 0.00
2017 XPR RESOURCES LLC Produced Fluid 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2018 XPR RESOURCES LLC Produced Fluid 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 XPR RESOURCES LLC Produced Fluid 148.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XPR RESOURCES LLC Produced Fluid 42.50 Bbl INJECTION DISPOSAL WELL 34-155-24079

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1952536 Primary Facility 2011-02-25 Compliance Evaluation Violation(s) Noted
1956546 Primary Facility 2011-01-31 Routine/Complete Inspection No Violations Noted
1962206 Primary Facility 2011-02-15 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
1963712 Primary Facility 2011-02-28 Compliance Evaluation Outstanding Violations - No Viols Req'd
1965713 Primary Facility 2011-03-04 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
1980488 Primary Facility 2011-04-18 Routine/Complete Inspection No Violations Noted
1980623 Primary Facility 2011-04-25 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
1981779 Primary Facility 2011-05-06 Routine/Complete Inspection No Violations Noted
1986263 Primary Facility 2011-05-12 Routine/Complete Inspection No Violations Noted
1988805 Primary Facility 2011-06-02 Routine/Complete Inspection No Violations Noted
2003958 Primary Facility 2011-07-29 Routine/Complete Inspection No Violations Noted
2005666 Primary Facility 2011-08-10 Routine/Complete Inspection No Violations Noted
2019243 Primary Facility 2011-09-06 Routine/Complete Inspection No Violations Noted
2021085 Primary Facility 2011-09-15 Routine/Complete Inspection No Violations Noted
2023572 Primary Facility 2011-09-27 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
2024057 Primary Facility 2011-12-05 Follow-up Inspection Violation(s) Noted
2024084 Primary Facility 2011-12-02 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
2024156 Primary Facility 2011-09-28 Follow-up Inspection No Violations Noted
2026337 Primary Facility 2011-10-25 Routine/Complete Inspection No Violations Noted
2029562 Primary Facility 2011-11-01 Routine/Complete Inspection No Violations Noted
2035158 Primary Facility 2011-12-02 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
2080709 Primary Facility 2012-05-21 Routine/Complete Inspection No Violations Noted
2145231 Primary Facility 2013-02-19 Routine/Complete Inspection No Violations Noted
2180649 Primary Facility 2013-07-02 Routine/Complete Inspection No Violations Noted
2182884 Primary Facility 2013-07-11 Routine/Complete Inspection No Violations Noted
2226779 Primary Facility 2013-12-03 Routine/Complete Inspection No Violations Noted
2450446 Primary Facility 2016-02-11 Routine/Complete Inspection No Violations Noted
2647293 Primary Facility 2017-10-06 Routine/Complete Inspection No Violations Noted Routine inspection of XPR Resources LLC, Recovery Recovery Well Pad 3 on October 10, 2017. No one was onsite during my inspection. PCSM installation has been completed. The contractor regraded the pad allowing water to flow towards the recently installed channel along the S and W border of the pad. This developed channel leads to an existing pond. The contractor applied E&S blanket along the developed channel and seed has been applied. The ditch along the access road leading to the well pad has been cleaned out. All BMPs remain in place. The pad remains at full build-out size (350'x550').

There are 4 producing wells on this pad: (027-21660, 027-21661, 027-21662, 027-21663). There are 2 production units onsite and (4) 400 BBL produced fluids tanks located in secondary containment. A trace of water was present within the produced fluids containment with a conductivity of 300 uS/cm.

No violations noted.

2670061 Primary Facility 2017-12-12 Routine/Complete Inspection No Violations Noted The weather is 26 Deg. F and cloudy, windy at time of inspection.

Routine inspection of XPR Resources LLC, Resource Recovery 3 Pad, Well # 1H on December 12, 2017. There are 4 producing wells on this pad: (Permits: 027-21660; 027-21661; 027-21662; 027-21663). Both annulus lines are open and plumbed to GPU at time of inspection. 0% combustible gas was detected at the annulus vent or in the area immediately surrounding the well. Digital gauge for the production tubing reads 145 PSI and located at Gas Processing Unit. No violations noted. XPR Resources LLC Representatives - Kevin Brady, Hydrologist, Environmental Scientist, Wetland Delineator and Heather Empfield, Permitting & Geologist ¿ XPR Resources. DEP Representative ¿ Ulyana Trynovich, Oil and Gas Inspector.

2795359 Primary Facility 2018-10-17 Routine/Complete Inspection No Violations Noted Routine site inspection with Heather Empfield of XPR Resources LLC at Recovery Recovery Well Pad 3 on October 17, 2018. PCSM installation has been completed. The contractor regraded the pad allowing water to flow towards the recently installed channel along the S and W border of the pad. This developed channel is fully vegetated and leads to an existing wet pond. The ditch along the access road leading to the well pad has been cleaned out. The pad remains at full build-out size (350'x550').

There are 4 producing wells on this pad: (027-21660, 027-21661, 027-21662, 027-21663). Each well head is properly tagged. There are 2 production units onsite and (4) 400 BBL produced fluids tanks located in secondary containment. As discussed during the site inspection with Ms. Empfield, the Department recommends submitting well site restoration reports for the 4 active wells onsite via Greenport.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1952536 605447 02/25/2011 2011-02-25 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. Environmental Health & Safety Violation noted by John Sengle on 2/25/2011documented as corrected by Sam Jones inspection of 3/4/2011.
1962206 607894 02/15/2011 2011-02-15 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative E&S mat is coming off ast various locations, HRI immediately repaired the E&S issues
1965713 608892 03/04/2011 2011-03-04 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. Administrative fluid level in pit exceeding 2' freeboard from excessive rain, pumper trucks on site removing fluids from the pit
1980623 613529 04/25/2011 2011-04-25 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative Had pummper trucks on site and pumping fluid out
2023572 625965 09/27/2011 2011-09-27 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. Administrative Failure to keep flow back and residue splash within the confines of the pit, need to clean up residue
2024057 626131 12/05/2011 2011-12-05 401CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
2024057 626132 12/05/2011 2011-12-05 6018.301 - Residual Waste is mismanaged. Environmental Health & Safety
2024057 626133 12/05/2011 2011-12-05 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. Administrative
2024084 626164 12/02/2011 2011-12-02 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Fluids and wastes from the area around the well head and cellar were allowed to make it to teh ground an dinto water in a pipeline trench
2035158 629644 12/02/2011 2011-12-02 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative Pit had insufficient capacity to keep all fluids and materials from teh flowing back of well into teh pit prior to removal to tanks or a centralized impoundment

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
605447 268375 NOV - Notice of Violation Comply/Closed 2011-03-04
626131 277897 NOV - Notice of Violation Comply/Closed 2014-11-12
626132 277897 NOV - Notice of Violation Comply/Closed 2014-11-12
626133 277897 NOV - Notice of Violation Comply/Closed 2014-11-12

For data sources see[8]