X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-031-25681

Well Details

Well ID: 37-031-25681
Loading map...
Country: United States
State: Pennsylvania
County: Clarion
Municipality: Farmington Township
Operator Name: UNKNOWN OPR
Well Pad ID:
Farm/Lease Name: WOLBERT
License Status: Plugged and Abandoned
Spud Date:
Permit Date:
Well Type: UNDETERMINED
Unconventional Well: N
Configuration: Undetermined
Conservation: No
Latitude: 41.386922
Longitude: -79.264111

For data sources see[1][2][3]

Well History

Date Event
1901-01-01 Drilling Completion
2016-08-16 OLD WELL
2018-08-13 Begin Plugging
2018-09-06 Finished Plugging
2018-10-16 Fully Plugged

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2646486 Primary Facility 2017-10-11 Routine/Complete Inspection No Violations Noted Inspected abandoned gas well. Residence close by. Continue smelling gas at residence. Well leaking when over pressures outside the production tubing. Well maybe broke needs plugged.
2763665 Primary Facility 2018-08-14 Plugging(Includes Plugged/Mined Through) No Violations Noted S&T Service and Supply cable tool rig on location. Well is being plugged with CFA grant due to the close proximity to a house. The well is currently venting into a poly tank so the well can be killed.
2768017 Primary Facility 2018-08-27 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspected plug job. Ran department down hole camera to identify depth of 3 inch and any holes in 3 inch tubing to cause gas bubbling up the annulus. There is a hole in the 3 " tubing @ 100 feet. S and T supply is the contractor for the CFA grant being used to plug this well.

S and T pumped 125 gallon of water dth to kill the well. Well was still gassing with fluid level @ 690'.

Plan is to pump 30 sks cement 8/28 am from td to 690', after reviewing several well logs in the area. Crew will return 6/29 tag the plug and complete a gas check. If more cement is needed they will pump more to bring plug up to 690. They will toh to 100 feet below 3 inch and set another 50' plug. 8/29 4 pm shooters will shoot off 3 inch @ 450' and s and t will toh 8/30 am. Camera run is scheduled for 8/30 pm to see where shallow gas is coming from and bottom if surface casing.

2770666 Primary Facility 2018-09-05 Plugging(Includes Plugged/Mined Through) No Violations Noted Ran downhole camera in well after well continued to vent gas. Fluid in the hole is at approximately 110'. No gas bubbles were seen at the fluid surface. We ran the camera lower in the hole and found multiple holes in the casing where the fluid is being drawn out of the well bore. No gas bubbles were seen anywhere in the fluid. Steve Lencer took a gas sample for possible isotopic analysis. Upon pulling the camera back up, multiple holes were seen in the casing above the fluid level. S&T tagged the cement plug at 385'. S&T plans to set an additional plug and load the hole with water so we can see where gas is entering the well bore.
2771411 Primary Facility 2018-09-06 Plugging(Includes Plugged/Mined Through) No Violations Noted Ran downhole camera into well. Lencer received a 100% methane reading in the casing. Water at 73', no bubbling noticed in water. Top of cement tagged at 100' .S&T loaded hole with water. Gas appears to be coming in to wellbore via a hole in the casing at approximately 45'. S&T filled well to approximately 60' with anti skid and pulled 80' of casing. Camera run showed crevasse at 45'. S&T cleaned out the well bore and loaded the hole with water to approximately 40'. No gas bubbles were seen. Hole was filled to approximately 35'. No gas bubbles were seen. Lencer checked for methane and received a 3% of LEL reading. S&T is going to set a rag packer on 1 1/2" at 30' so the well can vent and be monitored.
2771664 Primary Facility 2018-09-06 Plugging(Includes Plugged/Mined Through) No Violations Noted Rag packer set on 2" at 30'. 10 sacks of cement were set on the packer, to surface. The 2" will have a "T" installed at the top to enable gas monitoring.

S&T is currently readying equipment for demobilization.

2782031 Primary Facility 2018-10-01 Plugging(Includes Plugged/Mined Through) No Violations Noted Vent installed on plugged well so gas can be monitored. Equipment moved off site.

For data sources see[5]