If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-033-26961 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.126785,"lon":-78.35297,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Clearfield | |
Municipality: Goshen Township | |
Operator Name: GREYLOCK PROD LLC | |
Well Pad ID: 149570 | |
Farm/Lease Name: WHITETAIL 3MH | |
License Status: | |
Spud Date: | |
Permit Date: 2010-11-10 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.126785 | |
Longitude: -78.352970 |
Date | Event |
---|---|
2010-11-10 | New Permit Application |
2011-04-22 | Performed Spud Operation |
2011-10-27 | Drilling Completion |
2011-11-29 | Perforation |
2012-09-28 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-11-29 | 2011-11-29 | 7,464 | 4,060,770 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide EC 6116A | Universal Well Services | Biocide | Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00091000 | |
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00543000 | |||||
Proppant-40/70 | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 6.12 | ||
Proppant-40/70 | U.S. Well Services | Proppant | ||||||
15 Hydrochloric Acid (UWS) | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.08 | ||
LEB 10X | Universal Well Services | Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00059000 | ||
Water | ECA | Base Fluid | 90.80 | |||||
WGA-3, CMHPG | Universal Well Services | Dry Gellant | Guar gum | 9000-30-0 | 100.00 | 0.01 | ||
Scale Hib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.01 | ||
Unihib G | Universal Well Services | Corrosion Inhibitor for Acid | 2-Ethylhexanol | 104-76-7 | 75.00 | 0.00049000 | ||
Short chained glycol ether | 25.00 | 0.00016000 | ||||||
Proppant-100 Mesh | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 2.90 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ENERGY CORP OF AMER | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ENERGY CORP OF AMER | 30,336.00 | 24 | 0.00 | 0 | 0.00 | 0 |
2012 | ENERGY CORP OF AMER | 376,008.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2013 | ENERGY CORP OF AMER | 297,085.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2014 | ENERGY CORP OF AMER | 227,896.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | ENERGY CORP OF AMER | 137,107.00 | 349 | 0.00 | 0 | 0.00 | 0 |
2016 | ENERGY CORP OF AMER | 107,666.00 | 248 | 0.00 | 0 | 0.00 | 0 |
2017 | ENERGY CORP OF AMER | 152,003.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2018 | GREYLOCK PROD LLC | 128,282.00 | 356 | 0.00 | 0 | 0.00 | 0 |
2019 | GREYLOCK PROD LLC | 110,122.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | ENERGY CORP OF AMER | Produced Fluid | 440.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | ENERGY CORP OF AMER | Produced Fluid | 2,200.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011 | ENERGY CORP OF AMER | Drill Cuttings | 424.28 Tons | LANDFILL | 100434 |
2011 | ENERGY CORP OF AMER | Drilling Fluid Waste | 315.00 Bbl | LANDFILL | 100434 |
2012 | ENERGY CORP OF AMER | Produced Fluid | 23,569.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | ENERGY CORP OF AMER | Fracturing Fluid Waste | 17.62 Tons | LANDFILL | SWF 1025 |
2012 | ENERGY CORP OF AMER | Produced Fluid | 1,400.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | ENERGY CORP OF AMER | Fracing Fluid Waste | 11,345.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | ENERGY CORP OF AMER | Produced Fluid | 9,225.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | ENERGY CORP OF AMER | Produced Fluid | 5,715.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | ENERGY CORP OF AMER | Produced Fluid | 35.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2014 | ENERGY CORP OF AMER | Produced Fluid | 35.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24075 |
2014 | ENERGY CORP OF AMER | Produced Fluid | 5,328.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW006 |
2015 | ENERGY CORP OF AMER | Produced Fluid | 8,253.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2015 | ENERGY CORP OF AMER | Produced Fluid | 5,568.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | ENERGY CORP OF AMER | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | ENERGY CORP OF AMER | Produced Fluid | 630.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2016 | ENERGY CORP OF AMER | Produced Fluid | 136.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | ENERGY CORP OF AMER | Produced Fluid | 21,427.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | ENERGY CORP OF AMER | Other Oil & Gas Wastes | 15.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 1,861.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 319.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 8,340.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 50.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2018 | ENERGY CORP OF AMER | Produced Fluid | 6,037.00 Bbl | REUSE (AT WELL PAD) | |
2018 | GREYLOCK PROD LLC | Produced Fluid | 1,010.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2019 | GREYLOCK PROD LLC | Produced Fluid | 1,273.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2019 | GREYLOCK PROD LLC | Produced Fluid | 352.00 Bbl | REUSE (AT WELL PAD) | |
2019 | GREYLOCK PROD LLC | Produced Fluid | 349.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | GREYLOCK PROD LLC | Produced Fluid | 235.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1986421 | Primary Facility | 2011-07-08 | Compliance Evaluation | No Violations Noted | |
1992179 | Primary Facility | 2011-08-02 | Compliance Evaluation | No Violations Noted | |
2006924 | Primary Facility | 2011-09-29 | Compliance Evaluation | Violation(s) Noted | |
2009494 | Primary Facility | 2011-10-11 | Compliance Evaluation | No Violations Noted | |
2017074 | Primary Facility | 2011-11-07 | Compliance Evaluation | No Violations Noted | |
2044810 | Primary Facility | 2012-02-23 | Routine/Complete Inspection | No Violations Noted | |
2050191 | Primary Facility | 2012-03-13 | Routine/Complete Inspection | No Violations Noted | |
2058863 | Primary Facility | 2012-04-11 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | |
2095298 | Primary Facility | 2012-08-29 | Routine/Complete Inspection | Violation(s) Noted | |
2101592 | Primary Facility | 2012-09-20 | Routine/Complete Inspection | No Violations Noted | |
2102696 | Primary Facility | 2012-09-25 | Drilling/Alteration | No Violations Noted | |
2103386 | Primary Facility | 2012-09-27 | Follow-up Inspection | No Violations Noted | |
2107349 | Primary Facility | 2012-09-27 | Follow-up Inspection | No Violations Noted | |
2149180 | Primary Facility | 2013-03-19 | Routine/Complete Inspection | No Violations Noted | |
2179583 | Primary Facility | 2013-07-01 | Routine/Complete Inspection | No Violations Noted | |
2183996 | Primary Facility | 2013-07-17 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | |
2219900 | Primary Facility | 2013-11-07 | Routine/Complete Inspection | No Violations Noted | |
2224934 | Primary Facility | 2013-11-26 | Routine/Complete Inspection | No Violations Noted | |
2236359 | Primary Facility | 2014-01-15 | Routine/Complete Inspection | No Violations Noted | |
2264517 | Primary Facility | 2014-04-22 | Routine/Complete Inspection | No Violations Noted | |
2337438 | Primary Facility | 2015-01-15 | Routine/Complete Inspection | No Violations Noted | |
2362612 | Primary Facility | 2015-04-20 | Routine/Complete Inspection | No Violations Noted | |
2427906 | Primary Facility | 2015-11-25 | Routine/Complete Inspection | No Violations Noted | |
2482709 | Primary Facility | 2016-05-09 | Routine/Complete Inspection | No Violations Noted | |
2515275 | Primary Facility | 2016-08-30 | Routine/Complete Inspection | No Violations Noted | |
2554363 | Primary Facility | 2017-01-20 | Routine/Complete Inspection | No Violations Noted | |
2668308 | Primary Facility | 2017-12-01 | Routine/Complete Inspection | No Violations Noted | Routine inspection at Energy Corporation of America's (ECA) Whitetail #1 Pad on December 1, 2017. No one was onsite during my inspection. I later spoke with JD Sollon and Travis Wendel via phone on December 4, 2017 regarding some questions I had about this pad and ESCGP. Both gentlemen informed me that ECA was recently bought out by Grey Lock Energy (GLE). GLE is in the processing of having their well permits transferred from ECA to GLE. Both gentlemen are now employed by GLE.
The Whitetail #1 Pad has two producing Marcellus wells located on it (033-26961 and 033-27086). Both well cellars are full of water and no sheen was obsereved. I observed bubbling within the well cellar of 033-26961. I recommend the operator further investigate the bubbling. I will be referring this bubbling to one of the Departments Oil & Gas Inspector's for further investigation. Each well is connected to (2) 400 bbl produced fluids tanks which are stationed within a clay lined earthen secondary containment. A trace of water w |
2668812 | Primary Facility | 2017-12-08 | Follow-up Inspection | No Violations Noted | The weather is 28 Deg. F and cloudy, windy at time of inspection.
Follow up inspection of Energy Corporation of America, Whitetail 2MH Pad, well number 3MH on December 8, 2017. Annulus 9-5/8" was plumbed to the production line at time of inspection. Digital gauge on the production tubing reads 46 PSI pressure. 0% combustible gas was detected in the area immediately surrounding the well. Used plastic jug to capture bubbling and 4% LEL combustible gas was detected at the time of inspection. This was followed with pumping the water out of the cellar by vacuum truck. Visibly confirmed unknown combustible gas escaping the ground from the outside of the well casing. No violations noted. Discussed follow up inspection with company representative present on site. Energy Corporation of America representative - Roy Ricker - Production Foreman. |
2668978 | Primary Facility | 2017-12-08 | Follow-up Inspection | No Violations Noted | The weather is 28 Deg. F and cloudy, windy at time of inspection.
Follow up inspection of Energy Corporation of America, Whitetail 2MH Pad, well number 3MH on December 7, 2017. There are 2 producing wells on this pad: (Permits: 033-26961; 033-27086). Annulus 9-5/8" was plumbed to the poly tank at time of inspection. Digital gauge on the production tubing reads 44 PSI pressure. 0% combustible gas was detected in the area immediately surrounding the well. Visibly confirmed unknown combustible gas escaping the ground from the outside of the well casing. No violations noted. Discussed follow up inspection with company representative present on site. Energy Corporation of America representative - Roy Ricker - Production foreman and John Sollon - Lead PA Construction and Environmental Foreman. DEP Representative ¿ Ulyana Trynovich, Oil and Gas Inspector. |
2711059 | Primary Facility | 2018-03-27 | Follow-up Inspection | No Violations Noted | The weather is 40 Deg. F and cloudy, windy at time of inspection.
Follow up inspection of Greylock Production LLC., Whitetail Pad, well number 3MH on March 27, 2018. There are 2 active wells on site. This well is producing. Annulus (9-5/8" x 5-1/2¿) was plumbed to the poly tank at time of inspection. Digital gauge on the production tubing reads 42 PSI pressure. 0% combustible gas was detected in the poly tank or the area immediately surrounding the well. Visibly confirmed there is no combustible gas escaping the ground from the outside of the well casing during inspection. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector. |
2764475 | Primary Facility | 2018-08-14 | Routine/Complete Inspection | No Violations Noted | Department staff Sue Herzing, Sara Metz, and Mike Jurbala conducted a routine site inspection at Greylock Production LLC Whitetail #1 well pad and flowback impoundment on August 14, 2018. The operator is currently in the process of dewatering the flowback impoundment. Water is being hauled offsite via tank trucks. During the inspection we observed two holes within the flowback impoundment liner near the load-out area (photo 4). Another layer of liner was observed underneath the holes.
Greylock is currently in a Consent Order and Agreement (CO&A) with the Department finalized in November 2017. According to the CO&A the operator is required to restore this flowback impoundment and conduct site characterization, consisting of a sub-liner investigation after the liner is removed. If issues are found during that sub-liner investigation, then the operator shall conduct a site remediation in accordance with ACT 2. There are two producing wells located on the well pad (033-26961 and 033-27086). Each well is prop |
2786646 | Primary Facility | 2018-10-09 | Compliance Evaluation | No Violations Noted | I met with JD Sollon of Greylock on the site. Two skid steers and a 3- man crew were removing the liner and felt from the on-site impoundment. Moody & Associates group on location included Brandon Glowark, Ian Williams, Jona Stoskey, and Brynn Yochim. Moody was there to perform soil screening after the liner removal was completed; screening was to be for specific conductance, petroleum product, and rads. Although it appeared initially that the screening would begin while I was still on location, one of the skid steers threw a track and was being repaired until I departed. I noted several freshwater seeps on the northern slope of the impoundment, which were collecting mostly in the western side. The plan was to dig an interceptor trench across the north and west sides of the impoundment at the bottom to collect these seeps. Then Moody would perform the soil screening and take characterization samples. Once the liner was removed from the bottom of the impoundment, I walked the area taking soil conducta |
2811476 | Primary Facility | 2018-12-06 | Routine/Complete Inspection | No Violations Noted | Department representative Sue Herzing conducted a routine site inspection at Greylock Production LLC Whitetail flowback impoundment and well pad on December 6, 2018. The flowback impoundment has been completely reclaimed, seeded, and mulched. In addition, the well pad has been reduced in size on the S & SE sides. Both restored sides have been seeded and mulched. E&S BMPs and PCSMs remain in place and appear to be functioning as design.
Two Marcellus wells remain in production on the well pad. Well cellars are full of water and are frozen. Each well is connected to (2) 400 bbl produced fluids tanks which are stationed within a clay lined earthen secondary containment. Frozen water ~ 8-10" was observed in the earthen containment. A skid mounted compression and dehydration unit is stationed onsite. Gas leaving this Whitetail #1 pad is being fed to the NRG-Shawville Plant via a modified ECA transmission line. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2006924 | 621294 | 09/29/2011 | 2011-09-29 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative | |
2058863 | 636703 | 04/11/2012 | 2012-04-11 | 6018.301 - Residual Waste is mismanaged. | Environmental Health & Safety | |
2095298 | 647765 | 08/29/2012 | 2012-08-29 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | |
2183996 | 672793 | 07/17/2013 | 2013-07-17 | 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
621294 | 275738 | NOV - Notice of Violation | Comply/Closed | 2011-10-11 | |||
621294 | 278843 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-01-03 | 2012-01-03 | $11,128.00 | $11,128.00 |
647765 | 287928 | NOV - Notice of Violation | Comply/Closed | 2012-10-01 |
For data sources see[8]